{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T14:41:47Z","timestamp":1787064107966,"version":"build-2736575974"},"reference-count":36,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,1]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Severe right ventricular failure (RVF) after left ventricular assist device (LVAD) implantation increases morbidity and mortality. We investigated the association between intraoperative right heart hemodynamic data, echocardiographic parameters, and severe versus nonsevere RVF.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>A review of LVAD patients between March 2013 and March 2016 was performed. Severe RVF was defined by the need for a right ventricular mechanical support device, inotropic, and\/or inhaled pulmonary vasodilator requirements for &gt;14 days. From a chart review, the right ventricular failure risk score was calculated and right heart hemodynamic data were collected. Pulmonary artery pulsatility index (PAPi) [(pulmonary artery systolic pressure \u2212 pulmonary artery diastolic pressure)\/central venous pressure (CVP)] was calculated for 2 periods: (1) 30 minutes before cardiopulmonary bypass (CPB) and (2) after chest closure. Echocardiographic data were recorded pre-CPB and post-CPB by a blinded reviewer. Univariate logistic regression models were used to examine the performance of hemodynamic and echocardiographic metrics.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      A total of 110 LVAD patients were identified. Twenty-five did not meet criteria for RVF. Of the remaining 85 patients, 28 (33%) met criteria for severe RVF. Hemodynamic factors associated with severe RVF included: higher CVP values after chest closure (18 \u00b1 9 vs 13 \u00b1 5 mm Hg;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .0008) in addition to lower PAPi pre-CPB (1.2 \u00b1 0.6 vs 1.7 \u00b1 1.0;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .04) and after chest closure (0.9 \u00b1 0.5 vs 1.5 \u00b1 0.8;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .0008). Post-CPB echocardiographic findings associated with severe RVF included: larger right atrial diameter major axis (5.4 \u00b1 0.9 vs 4.9 \u00b1 1.0 cm;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .03), larger right ventricle end-systolic area (22.6 \u00b1 8.4 vs 18.5 \u00b1 7.9 cm\n                      <jats:sup>2<\/jats:sup>\n                      ;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .03), lower fractional area of change (20.2 \u00b1 10.8 vs 25.9 \u00b1 12.6;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .04), and lower tricuspid annular plane systolic excursion (0.9 \u00b1 0.2 vs 1.1 \u00b1 0.3 cm;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .008). Right ventricular failure risk score was not a significant predictor of severe RVF. Post-chest closure CVP and post-chest closure PAPi discriminated severe from nonsevere RVF better than other variables measured, each with an area under the curve of 0.75 (95% CI, 0.64\u20130.86).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Post-chest closure values of CVP and PAPi were significantly associated with severe RVF. Echocardiographic assessment of RV function post-CPB was weakly associated with severe RVF.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000003538","type":"journal-article","created":{"date-parts":[[2018,6,7]],"date-time":"2018-06-07T16:23:58Z","timestamp":1528388638000},"page":"25-32","source":"Crossref","is-referenced-by-count":49,"title":["Intraoperative Hemodynamic and Echocardiographic Measurements Associated With Severe Right Ventricular Failure After Left Ventricular Assist Device Implantation"],"prefix":"10.1213","volume":"128","author":[{"given":"Michael D.","family":"Gudejko","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Tufts Medical Center, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian R.","family":"Gebhardt","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Tufts Medical Center, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Farhad","family":"Zahedi","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Tufts Medical Center, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ankit","family":"Jain","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Tufts Medical Center, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Janis L.","family":"Breeze","sequence":"additional","affiliation":[{"name":"Tufts Clinical and Translational Science Institute, Tufts University, and Institute for Clinical Research and Health Policy Studies, Tufts Medical Center, Boston Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew R.","family":"Lawrence","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Tufts Medical Center, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stanton K.","family":"Shernan","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women\u2019s Hospital, Harvard Medical School, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Navin K.","family":"Kapur","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Tufts Medical Center, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael S.","family":"Kiernan","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Tufts Medical Center, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Greg","family":"Couper","sequence":"additional","affiliation":[{"name":"Department of Surgery, Tufts Medical Center, Boston, Massachusetts."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frederick C.","family":"Cobey","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Tufts Medical Center, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230721","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1161\/CIRCIMAGING.113.001127","article-title":"Assessment of right ventricular function in left ventricular assist device candidates.","volume":"7","author":"Hayek","year":"2014","journal-title":"Circ Cardiovasc Imaging"},{"key":"R2-20230721","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1016\/j.jtcvs.2008.09.021","article-title":"Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared to delayed conversion of LVAD to BiVAD.","volume":"137","author":"Fitzpatrick","year":"2009","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R3-20230721","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.athoracsur.2003.09.048","article-title":"Is severe right ventricular failure in left ventricular assist device recipients a risk factor for unsuccessful bridging to transplant and post-transplant mortality.","volume":"77","author":"Morgan","year":"2004","journal-title":"Ann Thorac Surg"},{"key":"R4-20230721","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1016\/j.healun.2005.07.002","article-title":"Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: third annual report\u20132005.","volume":"24","author":"Deng","year":"2005","journal-title":"J Heart Lung Transplant"},{"key":"R6-20230721","doi-asserted-by":"crossref","first-page":"2163","DOI":"10.1016\/j.jacc.2008.03.009","article-title":"The right ventricular failure risk score a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates.","volume":"51","author":"Matthews","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"R7-20230721","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1016\/j.amjcard.2009.11.026","article-title":"Risk factors predictive of right ventricular failure after left ventricular assist device implantation.","volume":"105","author":"Drakos","year":"2010","journal-title":"Am J Cardiol"},{"key":"R8-20230721","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.1016\/j.jtcvs.2009.11.020","article-title":"Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.","volume":"139","author":"Kormos","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R9-20230721","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1016\/j.athoracsur.2013.03.099","article-title":"Predicting right ventricular failure in the modern, continuous flow left ventricular assist device era.","volume":"96","author":"Atluri","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"R10-20230721","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1016\/j.acvd.2015.01.011","article-title":"Assessment of right ventricular dysfunction predictors before the implantation of a left ventricular assist device in end-stage heart failure patients using echocardiographic measures (ARVADE): combination of left and right ventricular echocardiographic variables.","volume":"108","author":"Aissaoui","year":"2015","journal-title":"Arch Cardiovasc Dis"},{"key":"R11-20230721","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1016\/S0894-7317(03)00335-3","article-title":"Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography.","volume":"16","author":"Zoghbi","year":"2003","journal-title":"J Am Soc Echocardiogr"},{"key":"R12-20230721","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.ccl.2012.03.008","article-title":"Right ventricular failure in patients with left ventricular assist devices.","volume":"30","author":"Rich","year":"2012","journal-title":"Cardiol Clin"},{"key":"R13-20230721","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/j.jtcvs.2006.08.104","article-title":"Left ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates.","volume":"133","author":"Zimpfer","year":"2007","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R14-20230721","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1056\/NEJMoa067758","article-title":"Use of a continuous-flow device in patients awaiting heart transplantation.","volume":"357","author":"Miller","year":"2007","journal-title":"N Engl J Med"},{"key":"R15-20230721","first-page":"971","article-title":"Reversibility of fixed pulmonary hypertension in left ventricular assist device support recipients.","volume":"40","author":"Mikus","year":"2011","journal-title":"Eur J Cardiothorac Surg"},{"key":"R16-20230721","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1093\/ejcts\/ezs678","article-title":"Use of centrifugal left ventricular assist device as a bridge to candidacy in severe heart failure with secondary pulmonary hypertension.","volume":"43","author":"Kutty","year":"2013","journal-title":"Eur J Cardiothorac Surg"},{"key":"R17-20230721","first-page":"II309","article-title":"Influence of left ventricular assist on valvular regurgitation.","volume":"88","author":"Holman","year":"1993","journal-title":"Circulation"},{"key":"R18-20230721","first-page":"163","article-title":"Ventricular interactions during mechanical circulatory support.","volume":"6","author":"Farrar","year":"1994","journal-title":"Semin Thorac Cardiovasc Surg"},{"key":"R19-20230721","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1007\/BF01656260","article-title":"Right heart interaction with the mechanically assisted left heart.","volume":"9","author":"Farrar","year":"1985","journal-title":"World J Surg"},{"key":"R20-20230721","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1161\/01.CIR.95.5.1320","article-title":"Septal function during left ventricular unloading.","volume":"95","author":"Moon","year":"1997","journal-title":"Circulation"},{"key":"R21-20230721","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.cardfail.2012.11.001","article-title":"Postoperative right ventricular failure after left ventricular assist device placement is predicted by preoperative echocardiographic structural, hemodynamic, and functional parameters.","volume":"19","author":"Raina","year":"2013","journal-title":"J Card Fail"},{"key":"R22-20230721","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.healun.2011.11.003","article-title":"Decision tree for adjuvant right ventricular support in patients receiving a left ventricular assist device.","volume":"31","author":"Wang","year":"2012","journal-title":"J Heart Lung Transplant"},{"key":"R23-20230721","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.1016\/j.healun.2015.05.005","article-title":"Validation of clinical scores for right ventricular failure prediction after implantation of continuous-flow left ventricular assist devices.","volume":"34","author":"Kalogeropoulos","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"R24-20230721","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1161\/CIRCIMAGING.111.965335","article-title":"Echocardiographic variables after left ventricular assist device implantation associated with adverse outcome.","volume":"4","author":"Topilsky","year":"2011","journal-title":"Circ Cardiovasc Imaging"},{"key":"R25-20230721","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.cardfail.2015.10.019","article-title":"Pulmonary artery pulsatility index is associated with right ventricular failure after left ventricular assist device surgery.","volume":"22","author":"Morine","year":"2016","journal-title":"J Card Fail"},{"key":"R26-20230721","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.healun.2015.06.009","article-title":"Pulmonary artery pulsatility index predicts right ventricular failure after left ventricular assist device implantation.","volume":"35","author":"Kang","year":"2016","journal-title":"J Heart Lung Transplant"},{"key":"R27-20230721","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1002\/ccd.23309","article-title":"The pulmonary artery pulsatility index identifies severe right ventricular dysfunction in acute inferior myocardial infarction.","volume":"80","author":"Korabathina","year":"2012","journal-title":"Catheter Cardiovasc Interv"},{"key":"R28-20230721","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/j.jacc.2012.02.073","article-title":"Independent and incremental role of quantitative right ventricular evaluation for the prediction of right ventricular failure after left ventricular assist device implantation.","volume":"60","author":"Grant","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"R29-20230721","doi-asserted-by":"crossref","first-page":"1102","DOI":"10.1016\/j.healun.2008.07.022","article-title":"Tricuspid annular motion as a predictor of severe right ventricular failure after left ventricular assist device implantation.","volume":"27","author":"Puwanant","year":"2008","journal-title":"J Heart Lung Transplant"},{"key":"R30-20230721","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1016\/j.healun.2008.08.012","article-title":"Tricuspid incompetence and geometry of the right ventricle as predictors of right ventricular function after implantation of a left ventricular assist device.","volume":"27","author":"Potapov","year":"2008","journal-title":"J Heart Lung Transplant"},{"key":"R31-20230721","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.jcmg.2010.10.012","article-title":"Echocardiographic predictors of adverse outcomes after continuous left ventricular assist device implantation.","volume":"4","author":"Topilsky","year":"2011","journal-title":"JACC Cardiovasc Imaging"},{"key":"R32-20230721","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.amjcard.2011.08.040","article-title":"Usefulness of two-dimensional echocardiographic parameters of the left side of the heart to predict right ventricular failure after left ventricular assist device implantation.","volume":"109","author":"Kato","year":"2012","journal-title":"Am J Cardiol"},{"key":"R33-20230721","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.jchf.2013.02.005","article-title":"Serial echocardiography using tissue Doppler and speckle tracking imaging to monitor right ventricular failure before and after left ventricular assist device surgery.","volume":"1","author":"Kato","year":"2013","journal-title":"JACC Heart Fail"},{"key":"R34-20230721","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1016\/j.healun.2013.05.016","article-title":"Increased right-to-left ventricle diameter ratio is a strong predictor of right ventricular failure after left ventricular assist device.","volume":"32","author":"Vivo","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"R35-20230721","doi-asserted-by":"crossref","first-page":"H2140","DOI":"10.1152\/ajpheart.00566.2004","article-title":"Reservoir and conduit function of right atrium: impact on right ventricular filling and cardiac output.","volume":"288","author":"Gaynor","year":"2005","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"R36-20230721","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.healun.2010.09.006","article-title":"Right-to-left ventricular end-diastolic diameter ratio and prediction of right ventricular failure with continuous-flow left ventricular assist devices.","volume":"30","author":"Kukucka","year":"2011","journal-title":"J Heart Lung Transplant"},{"key":"R37-20230721","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.cardfail.2014.12.009","article-title":"Preoperative three-dimensional echocardiography to assess risk of right ventricular failure after left ventricular assist device surgery.","volume":"21","author":"Kiernan","year":"2015","journal-title":"J Card Fail"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00000539-201901000-00010","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:19:51Z","timestamp":1786112391000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00000539-201901000-00010"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1]]},"references-count":36,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000003538","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2019,1]]}}}