{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T19:12:39Z","timestamp":1793387559379,"version":"4.5.0"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>In patients with an unstable cervical spine, maintenance of cervical immobilization during tracheal intubation is important. In McGrath videolaryngoscopic intubation, lifting of the blade to raise the epiglottis is needed to visualize the glottis, but in patients with an unstable cervical spine, this can cause cervical spine movement. By contrast, the Optiscope, a rigid video-stylet, does not require raising of the epiglottis during tracheal intubation. We therefore hypothesized that the Optiscope would produce less cervical spine movement than the McGrath videolaryngoscope during tracheal intubation. The aim of this study was to compare the Optiscope with the McGrath videolaryngoscope with respect to cervical spine motion during intubation in patients with simulated cervical immobilization.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>The primary outcome of the study was the extent of cervical spine motion at the occiput\u2013C1, C1\u2013C2, and C2\u2013C5 segments. In this randomized crossover study, the cervical spine angle was measured before and during tracheal intubation using either the Optiscope or the McGrath videolaryngoscope in 21 patients with simulated cervical immobilization. Cervical spine motion was defined as the change in angle at each cervical segment during tracheal intubation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>There was significantly less cervical spine motion at the occiput\u2013C1 segment using the Optiscope rather than the McGrath videolaryngoscope (mean [98.33% CI]: 4.7\u00b0 [2.4\u20137.0] vs 10.4\u00b0 [8.1\u201312.7]; mean difference [98.33% CI]: \u22125.7\u00b0 [\u22127.5 to \u22123.9]). There were also fewer cervical spinal motions at the C1\u2013C2 and C2\u2013C5 segments using the Optiscope (mean difference versus the McGrath videolaryngoscope [98.33% CI]: \u22122.4\u00b0 [\u22123.7 to \u22121.2]) and \u22123.7\u00b0 [\u22125.9 to \u22121.4], respectively).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>The Optiscope produces less cervical spine motion than the McGrath videolaryngoscope during tracheal intubation of patients with simulated cervical immobilization.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000003635","type":"journal-article","created":{"date-parts":[[2018,6,29]],"date-time":"2018-06-29T04:14:23Z","timestamp":1530245663000},"page":"1666-1672","source":"Crossref","is-referenced-by-count":16,"title":["Cervical Spine Motion During Tracheal Intubation Using an Optiscope Versus the McGrath Videolaryngoscope in Patients With Simulated Cervical Immobilization: A Prospective Randomized Crossover Study"],"prefix":"10.1213","volume":"129","author":[{"given":"Karam","family":"Nam","sequence":"first","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Younsuk","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, Dongguk University Medical Center Ilsan Hospital, Dongguk University College of Medicine, Goyang, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hee-Pyoung","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaeyeon","family":"Chung","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyun-Kyu","family":"Yoon","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tae Kyong","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230721","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1007\/BF03017455","article-title":"Airway management after upper cervical spine injury: what have we learned?","volume":"49","author":"Crosby","year":"2002","journal-title":"Can J Anaesth"},{"key":"R2-20230721","doi-asserted-by":"crossref","first-page":"1274","DOI":"10.1213\/00000539-200011000-00041","article-title":"Cervical spine motion during airway management: a cinefluoroscopic study of the posteriorly destabilized third cervical vertebrae in human cadavers.","volume":"91","author":"Brimacombe","year":"2000","journal-title":"Anesth Analg"},{"key":"R3-20230721","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1097\/BRS.0b013e31822419fe","article-title":"Comparison of 4 airway devices on cervical spine alignment in a cadaver model with global ligamentous instability at C5-C6.","volume":"37","author":"Prasarn","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"key":"R4-20230721","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1213\/ANE.0b013e318279b37a","article-title":"A comparison of 4 airway devices on cervical spine alignment in cadaver models of global ligamentous instability at c1-2.","volume":"117","author":"Wendling","year":"2013","journal-title":"Anesth Analg"},{"key":"R5-20230721","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1213\/01.ane.0000166975.38649.27","article-title":"Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope.","volume":"101","author":"Turkstra","year":"2005","journal-title":"Anesth Analg"},{"key":"R6-20230721","doi-asserted-by":"crossref","first-page":"1341","DOI":"10.1111\/anae.13606","article-title":"A prospective randomised study of a rigid video-stylet vs conventional lightwand intubation in cervical spine-immobilised patients.","volume":"71","author":"Seo","year":"2016","journal-title":"Anaesthesia"},{"key":"R7-20230721","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1213\/ANE.0000000000001813","article-title":"A randomized crossover study comparing cervical spine motion during intubation between two lightwand intubation techniques in patients with simulated cervical immobilization: laryngoscope-assisted versus conventional lightwand intubation.","volume":"125","author":"Kim","year":"2017","journal-title":"Anesth Analg"},{"key":"R8-20230721","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1213\/ane.0b013e318161769e","article-title":"Cervical spine motion during tracheal intubation with manual in-line stabilization: direct laryngoscopy versus GlideScope videolaryngoscopy.","volume":"106","author":"Robitaille","year":"2008","journal-title":"Anesth Analg"},{"key":"R9-20230721","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1093\/bja\/aev205","article-title":"Alternative intubation techniques vs Macintosh laryngoscopy in patients with cervical spine immobilization: systematic review and meta-analysis of randomized controlled trials.","volume":"116","author":"Suppan","year":"2016","journal-title":"Br J Anaesth"},{"key":"R10-20230721","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1111\/anae.13384","article-title":"A randomised cross-over trial comparing the McGrath(\u00ae) Series 5 videolaryngoscope with the Macintosh laryngoscope in patients with cervical spine immobilisation.","volume":"71","author":"Foulds","year":"2016","journal-title":"Anaesthesia"},{"key":"R11-20230721","doi-asserted-by":"crossref","first-page":"213","DOI":"10.4097\/kjae.2015.68.3.213","article-title":"Airway management of patients with traumatic brain injury\/C-spine injury.","volume":"68","author":"Jung","year":"2015","journal-title":"Korean J Anesthesiol"},{"key":"R12-20230721","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1111\/j.1399-6576.2011.02541.x","article-title":"Forces applied to the maxillary incisors by video laryngoscopes and the Macintosh laryngoscope.","volume":"56","author":"Lee","year":"2012","journal-title":"Acta Anaesthesiol Scand"},{"key":"R13-20230721","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1111\/j.1365-2044.2012.07087.x","article-title":"Measurement of forces applied during Macintosh direct laryngoscopy compared with GlideScope\u00ae videolaryngoscopy.","volume":"67","author":"Russell","year":"2012","journal-title":"Anaesthesia"},{"key":"R14-20230721","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1097\/ALN.0b013e318190b556","article-title":"Manual in-line stabilization increases pressures applied by the laryngoscope blade during direct laryngoscopy and orotracheal intubation.","volume":"110","author":"Santoni","year":"2009","journal-title":"Anesthesiology"},{"key":"R15-20230721","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1007\/BF03022029","article-title":"Cervical spine motion: a fluoroscopic comparison of Shikani Optical Stylet vs Macintosh laryngoscope.","volume":"54","author":"Turkstra","year":"2007","journal-title":"Can J Anaesth"},{"key":"R16-20230721","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1097\/00007632-199706010-00008","article-title":"The effect of airway maneuvers on the unstable C1-C2 segment. A cadaver study.","volume":"22","author":"Donaldson","year":"1997","journal-title":"Spine (Phila Pa 1976)"},{"issue":"suppl 1","key":"R17-20230721","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1227\/01.neu.0000430319.32247.7f","article-title":"Guidelines for the management of acute cervical spine and spinal cord injuries: 2013 update.","volume":"60","author":"Walters","year":"2013","journal-title":"Neurosurgery"},{"key":"R18-20230721","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1111\/j.1365-2044.2010.06334.x","article-title":"A comparison of the Airway Scope and McCoy laryngoscope in patients with simulated restricted neck mobility.","volume":"65","author":"Komatsu","year":"2010","journal-title":"Anaesthesia"},{"key":"R19-20230721","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1093\/bja\/aei190","article-title":"Reduction in mouth opening with semi-rigid cervical collars.","volume":"95","author":"Goutcher","year":"2005","journal-title":"Br J Anaesth"},{"key":"R20-20230721","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1097\/00003643-200411000-00013","article-title":"Three-dimensional cervical spine movement during intubation using the Macintosh and Bullard laryngoscopes, the bonfils fibrescope and the intubating laryngeal mask airway.","volume":"21","author":"Wahlen","year":"2004","journal-title":"Eur J Anaesthesiol"},{"key":"R21-20230721","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1111\/j.1365-2044.2005.04224.x","article-title":"Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope.","volume":"60","author":"Rudolph","year":"2005","journal-title":"Anaesthesia"},{"key":"R22-20230721","doi-asserted-by":"crossref","first-page":"e7817","DOI":"10.1097\/MD.0000000000007817","article-title":"Endotracheal intubation in elective cervical surgery: a randomized, controlled, assessor-blinded study.","volume":"96","author":"Fan","year":"2017","journal-title":"Medicine (Baltimore)"},{"key":"R23-20230721","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1097\/ALN.0b013e31827773b2","article-title":"Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway.","volume":"118","author":"Apfelbaum","year":"2013","journal-title":"Anesthesiology"},{"key":"R24-20230721","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1093\/bja\/aev371","article-title":"Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults.","volume":"115","author":"Frerk","year":"2015","journal-title":"Br J Anaesth"},{"key":"R25-20230721","first-page":"577","article-title":"Tracheal intubation using the mobile C-MAC video laryngoscope or direct laryngoscopy for patients with a simulated difficult airway.","volume":"76","author":"Byhahn","year":"2010","journal-title":"Minerva Anestesiol"},{"key":"R26-20230721","doi-asserted-by":"crossref","first-page":"314","DOI":"10.4097\/kjae.2010.59.5.314","article-title":"Comparison of the laryngeal view during intubation using Airtraq and Macintosh laryngoscopes in patients with cervical spine immobilization and mouth opening limitation.","volume":"59","author":"Koh","year":"2010","journal-title":"Korean J Anesthesiol"},{"key":"R27-20230721","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1093\/bja\/aen207","article-title":"Randomized cross-over comparison of cervical-spine motion with the AirWay Scope or Macintosh laryngoscope with in-line stabilization: a video-fluoroscopic study.","volume":"101","author":"Maruyama","year":"2008","journal-title":"Br J Anaesth"},{"issue":"suppl 1","key":"R28-20230721","first-page":"S63","article-title":"Randomized cinefluoroscopic comparison of cervical spine motion using McGrath series 5 and Macintosh laryngoscope for intubation with manual in-line stabilization.","volume":"98","author":"Laosuwan","year":"2015","journal-title":"J Med Assoc Thai"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000003635","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:20:01Z","timestamp":1786112401000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000003635"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000003635","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2019,12]]}}}