{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T18:16:14Z","timestamp":1792001774748,"version":"4.4.0"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,6]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Pediatric anesthesiologists are exposed to ionizing radiation from x-rays on an almost daily basis. Our goal was to determine the culture of safety in which they work and how they adhere to preventative strategies that minimize exposure risk in their daily practice.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>\n                      After Institutional Review Board waiver and approval of the Society for Pediatric Anesthesia\u2019s research and quality and safety committees, an electronic e-mail questionnaire was sent to the Society\u2019s physician, nontrainee members and consisted of questions specific to provider use of protective lead shielding, the routine use of dosimeters, and demographic information. Univariate analyses were performed using the Wilcoxon rank sum test for ordinal variables, the Fisher exact test for categorical variables, and the Spearman test to analyze correlation between 2 ordinal variables, while a proportional odds logistic regression was used for a multivariable ordinal outcome analysis.\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      values of &lt;.05 were considered statistically significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Twenty-one percent (674\/3151) of the surveyed anesthesiologists completed the online questionnaire. Radiation exposure is ubiquitous (98.7%), and regardless of sex, most respondents were either concerned or very concerned about radiation exposure (76.8%); however, women were significantly more concerned than men (proportional odds ratio, 1.66 [95% confidence interval, 1.20\u20132.31];\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .002). Despite this and independent of sex, level of concern was not associated with use of a radiation dosimeter (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .85), lead glasses (odds ratio, 1.07 [95% confidence interval, 0.52\u20132.39];\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 1.0), or a thyroid shield (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .12). Dosimeters were rarely (13%) or never used (52%) and were mandated in only 28.5% of institutions. Virtually none of the respondents had ever taken a radiation safety course, received a personal radiation dose report, notification of their radiation exposure, or knew how many millirem\/y was considered safe. Half of the respondents were female, and while pregnant, 73% (151\/206) tried to avoid radiation exposure by requesting not to be assigned to cases requiring x-rays. These requests were honored 78% (160\/206) of the time.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>DISCUSSION:<\/jats:title>\n                    <jats:p>Despite universal exposure to ionizing radiation from x-rays, pediatric anesthesiologists do not routinely adhere to strategies designed to limit the intensity of this exposure and rarely work in institutions in which a culture of radiation safety exists. Our study highlights the need to improve radiation safety education, the need to change the safety culture within the operating rooms and imaging suites, and the need to more fully investigate the utility of dosimeters, lead shielding, and eye safety measures in pediatric anesthesia practice.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000003773","type":"journal-article","created":{"date-parts":[[2018,9,7]],"date-time":"2018-09-07T08:51:26Z","timestamp":1536310286000},"page":"1242-1248","source":"Crossref","is-referenced-by-count":21,"title":["Radiation Safety Perceptions and Practices Among Pediatric Anesthesiologists: A Survey of the Physician Membership of the Society for Pediatric Anesthesia"],"prefix":"10.1213","volume":"128","author":[{"given":"Gina M.","family":"Whitney","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, University of Colorado, Children\u2019s Hospital Colorado, Aurora, Colorado"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James J.","family":"Thomas","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, University of Colorado, Children\u2019s Hospital Colorado, Aurora, Colorado"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas M.","family":"Austin","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Emory University School of Medicine, Atlanta, Georgia."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jemel","family":"Fanfan","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Emory University School of Medicine, Atlanta, Georgia."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Myron","family":"Yaster","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, University of Colorado, Children\u2019s Hospital Colorado, Aurora, Colorado"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R2-20230721","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1097\/00005131-199708000-00002","article-title":"Radiation exposure to the orthopaedic surgical team during fluoroscopy: \u201chow far away is far enough?\u201d","volume":"11","author":"Mehlman","year":"1997","journal-title":"J Orthop Trauma"},{"key":"R3-20230721","doi-asserted-by":"crossref","first-page":"1725","DOI":"10.1213\/01.ANE.0000184039.00652.B8","article-title":"Radiation exposure to anesthesia personnel: the impact of an electrophysiology laboratory.","volume":"101","author":"Katz","year":"2005","journal-title":"Anesth Analg"},{"key":"R6-20230721","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1177\/1089253217692110","article-title":"Occupational radiation exposure of anesthesia providers: a summary of key learning points and resident-led radiation safety projects.","volume":"21","author":"Wang","year":"2017","journal-title":"Semin Cardiothorac Vasc Anesth"},{"key":"R7-20230721","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.ssci.2015.07.029","article-title":"Danger zone: men, masculinity and occupational health and safety in high risk occupations.","volume":"80","author":"Stergiou-Kita","year":"2015","journal-title":"Saf Sci"},{"key":"R9-20230721","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1053\/j.tvir.2010.03.005","article-title":"Operator shielding: how and why.","volume":"13","author":"Schueler","year":"2010","journal-title":"Tech Vasc Interv Radiol"},{"key":"R10-20230721","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1007\/s00402-015-2257-z","article-title":"The compliance with and knowledge about radiation protection in operating room personnel: a cross-sectional study with a questionnaire.","volume":"135","author":"Jentzsch","year":"2015","journal-title":"Arch Orthop Trauma Surg"},{"key":"R11-20230721","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1302\/0301-620X.83B6.0830815","article-title":"Scattered radiation during fixation of hip fractures. Is distance alone enough protection?","volume":"83","author":"Alonso","year":"2001","journal-title":"J Bone Joint Surg Br"},{"key":"R12-20230721","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1111\/anae.13400","article-title":"Radiation safety for anaesthesia providers in the orthopaedic operating room.","volume":"71","author":"Rhea","year":"2016","journal-title":"Anaesthesia"},{"key":"R13-20230721","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1259\/0007-1285-61-722-128","article-title":"Lead thickness in shielding in the protection of radiodiagnostic staff.","volume":"61","author":"Russell","year":"1988","journal-title":"Br J Radiol"},{"key":"R14-20230721","doi-asserted-by":"crossref","first-page":"S278","DOI":"10.1016\/j.jvir.2009.04.027","article-title":"Occupational health hazards in the interventional laboratory: time for a safer environment.","volume":"20","author":"Klein","year":"2009","journal-title":"J Vasc Interv Radiol"},{"key":"R15-20230721","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1136\/jnis.2010.003368","article-title":"Occupational health hazards in the interventional laboratory: progress report of the Multispecialty Occupational Health Group.","volume":"2","author":"Miller","year":"2010","journal-title":"J Neurointerv Surg"},{"key":"R16-20230721","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1093\/bja\/76.6.868","article-title":"Occupational x-ray exposure of anaesthetists.","volume":"76","author":"McGowan","year":"1996","journal-title":"Br J Anaesth"},{"key":"R17-20230721","doi-asserted-by":"crossref","first-page":"1240","DOI":"10.1097\/BRS.0b013e31824589d5","article-title":"Measurements of surgeons\u2019 exposure to ionizing radiation dose during intraoperative use of C-arm fluoroscopy.","volume":"37","author":"Lee","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"key":"R18-20230721","doi-asserted-by":"crossref","first-page":"2108","DOI":"10.1097\/BRS.0b013e3182a8270d","article-title":"Types and arrangement of thyroid shields to reduce exposure of surgeons to ionizing radiation during intraoperative use of C-arm fluoroscopy.","volume":"38","author":"Lee","year":"2013","journal-title":"Spine (Phila Pa 1976)"},{"key":"R19-20230721","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1038\/ajg.2016.540","article-title":"Ocular radiation threshold projection based off of fluoroscopy time during ERCP.","volume":"112","author":"Garg","year":"2017","journal-title":"Am J Gastroenterol"},{"key":"R20-20230721","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1007\/s10877-016-9857-1","article-title":"Eye lens dosimetry in anesthesiology: a prospective study.","volume":"31","author":"Vaes","year":"2017","journal-title":"J Clin Monit Comput"},{"key":"R21-20230721","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1097\/ALN.0b013e31820c2b81","article-title":"Radiation exposure of the anesthesiologist in the neurointerventional suite.","volume":"114","author":"Anastasian","year":"2011","journal-title":"Anesthesiology"},{"key":"R22-20230721","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1097\/00004424-198708000-00012","article-title":"The case for radioprotective eyewear\/facewear. Practical implications and suggestions.","volume":"22","author":"Cousin","year":"1987","journal-title":"Invest Radiol"},{"key":"R23-20230721","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1093\/intqhc\/mzg031","article-title":"Good practice in the conduct and reporting of survey research.","volume":"15","author":"Kelley","year":"2003","journal-title":"Int J Qual Health Care"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00000539-201906000-00032","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:22:18Z","timestamp":1786112538000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00000539-201906000-00032"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6]]},"references-count":19,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000003773","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2019,6]]}}}