{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T06:15:17Z","timestamp":1792131317886,"version":"4.4.0"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,9]]},"abstract":"<jats:p>\n                    Regional cerebral oxygenation index (rSO\n                    <jats:sub>2<\/jats:sub>\n                    ) based on near-infrared spectroscopy (NIRS) is frequently used to detect low venous oxyhemoglobin saturation (ScvO\n                    <jats:sub>2<\/jats:sub>\n                    ). We compared the performance of 2 generations of NIRS devices. Clinically obtained, time-matched cerebral rSO\n                    <jats:sub>2<\/jats:sub>\n                    and ScvO\n                    <jats:sub>2<\/jats:sub>\n                    values were compared in infants monitored with the FORE-SIGHT (n = 73) or FORE-SIGHT ELITE (n = 47) by linear regression and Bland-Altman analyses. In both devices, cerebral rSO\n                    <jats:sub>2<\/jats:sub>\n                    correlated poorly with measured ScvO\n                    <jats:sub>2<\/jats:sub>\n                    (FORE-SIGHT partial correlation 0.50 [95% confidence interval {CI}, 0.40\u20130.58]; FORE-SIGHT ELITE partial correlation 0.47 [0.39\u20130.55]) and mean bias was +8 (standard deviation [SD] 13.2) for FORE-SIGHT and +14 (SD 12.5) for FORE-SIGHT ELITE. When ScvO\n                    <jats:sub>2<\/jats:sub>\n                    was &lt;30%, rSO\n                    <jats:sub>2<\/jats:sub>\n                    was &lt;40 in 8% of FORE-SIGHT ELITE readings. Future NIRS should be validated in more hypoxic cohorts.\n                  <\/jats:p>","DOI":"10.1213\/ane.0000000000004580","type":"journal-article","created":{"date-parts":[[2020,1,27]],"date-time":"2020-01-27T08:36:57Z","timestamp":1580114217000},"page":"e138-e141","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":9,"title":["Sensitivity of a Next-Generation NIRS Device to Detect Low Mixed Venous Oxyhemoglobin Saturations in the Single Ventricle Population"],"prefix":"10.1213","volume":"131","author":[{"given":"Marie-Helene","family":"Gagnon","sequence":"first","affiliation":[{"name":"Department of Cardiology, Boston Children\u2019s Hospital, Boston, Massachusetts"},{"name":"Department of Pediatrics, Harvard Medical School, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barry D.","family":"Kussman","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Critical Care and Pain Medicine, Boston Children\u2019s Hospital, Boston, Massachusetts"},{"name":"Department of Anaesthesia, Harvard Medical School, Boston, Massachusetts."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingyu","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Boston Children\u2019s Hospital, Boston, Massachusetts"},{"name":"Department of Pediatrics, Harvard Medical School, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James A.","family":"DiNardo","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Critical Care and Pain Medicine, Boston Children\u2019s Hospital, Boston, Massachusetts"},{"name":"Department of Anaesthesia, Harvard Medical School, Boston, Massachusetts."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John N.","family":"Kheir","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Boston Children\u2019s Hospital, Boston, Massachusetts"},{"name":"Department of Pediatrics, Harvard Medical School, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,1,20]]},"reference":[{"key":"R1-20250227","doi-asserted-by":"crossref","first-page":"eaan0117","DOI":"10.1126\/scitranslmed.aan0117","article-title":"Responsive monitoring of mitochondrial redox states in heart muscle predicts impending cardiac arrest.","volume":"9","author":"Perry","year":"2017","journal-title":"Sci Transl Med"},{"key":"R2-20250227","doi-asserted-by":"crossref","first-page":"1515","DOI":"10.1016\/S0003-4975(00)01772-0","article-title":"Venous saturation and the anaerobic threshold in neonates after the Norwood procedure for hypoplastic left heart syndrome.","volume":"70","author":"Hoffman","year":"2000","journal-title":"Ann Thorac Surg"},{"key":"R3-20250227","doi-asserted-by":"crossref","first-page":"I82","DOI":"10.1161\/01.cir.0000032878.55215.bd","article-title":"Improved survival of patients undergoing palliation of hypoplastic left heart syndrome: lessons learned from 115 consecutive patients.","volume":"106","author":"Tweddell","year":"2002","journal-title":"Circulation"},{"key":"R4-20250227","doi-asserted-by":"crossref","first-page":"e003554","DOI":"10.1161\/JAHA.116.003554","article-title":"Phosphodiesterase inhibitor-based vasodilation improves oxygen delivery and clinical outcomes following stage 1 palliation.","volume":"5","author":"Mills","year":"2016","journal-title":"J Am Heart Assoc"},{"key":"R5-20250227","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1016\/S0022-5223(03)01315-1","article-title":"Alteration of the critical arteriovenous oxygen saturation relationship by sustained afterload reduction after the Norwood procedure.","volume":"127","author":"Hoffman","year":"2004","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R6-20250227","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1097\/EJA.0b013e32833bf5c5","article-title":"The pediaSat continuous central SvO2 monitoring system does not reliably indicate state or course of central venous oxygenation.","volume":"27","author":"Baulig","year":"2010","journal-title":"Eur J Anaesthesiol"},{"key":"R7-20250227","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.jtcvs.2011.09.007","article-title":"Predictive value of near-infrared spectroscopy on neurodevelopmental outcome after surgery for congenital heart disease in infancy.","volume":"143","author":"Simons","year":"2012","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R8-20250227","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/S0022-5223(97)70074-6","article-title":"Benefit of neurophysiologic monitoring for pediatric cardiac surgery.","volume":"114","author":"Austin","year":"1997","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R9-20250227","doi-asserted-by":"crossref","first-page":"1056","DOI":"10.1016\/j.jtcvs.2017.03.154","article-title":"Cerebral near-infrared spectroscopy insensitively detects low cerebral venous oxygen saturations after stage 1 palliation.","volume":"154","author":"Rescoe","year":"2017","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R10-20250227","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1213\/ANE.0000000000002796","article-title":"Validation of a second-generation near-infrared spectroscopy monitor in children with congenital heart disease.","volume":"128","author":"Nasr","year":"2019","journal-title":"Anesth Analg"},{"key":"R11-20250227","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1007\/s10877-017-0015-1","article-title":"A validation method for near-infrared spectroscopy based tissue oximeters for cerebral and somatic tissue oxygen saturation measurements.","volume":"32","author":"Benni","year":"2018","journal-title":"J Clin Monit Comput"},{"key":"R12-20250227","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1002\/bimj.200510192","article-title":"Estimating correlation coefficient between two variables with repeated observations using mixed effects model.","volume":"48","author":"Roy","year":"2006","journal-title":"Biom J"},{"key":"R13-20250227","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1080\/10543400701329422","article-title":"Agreement between methods of measurement with multiple observations per individual.","volume":"17","author":"Bland","year":"2007","journal-title":"J Biopharm Stat"},{"key":"R14-20250227","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1097\/00004647-200203000-00011","article-title":"Near-infrared spectroscopy cerebral oxygen saturation thresholds for hypoxia-ischemia in piglets.","volume":"22","author":"Kurth","year":"2002","journal-title":"J Cereb Blood Flow Metab"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000004580","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:36:17Z","timestamp":1786113377000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000004580"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,20]]},"references-count":14,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000004580","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2020,1,20]]}}}