{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T04:58:41Z","timestamp":1790744321025,"version":"4.1.0"},"reference-count":44,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,4]]},"abstract":"<jats:p>Tracheotomy is a surgical procedure through which a tracheostomy, an opening into the trachea, is created. Indications for tracheostomy include facilitation of airway management during prolonged mechanical ventilation, treatment of acute upper airway obstruction when tracheal intubation is unfeasible, management of chronic upper airway obstructive conditions, and planned airway management for major head and neck surgery. Patients who have a recent or long-term tracheostomy may present for a variety of surgical or diagnostic procedures performed under general anesthesia or sedation\/analgesia. Airway management of these patients can be challenging and should be planned ahead of time. Anesthesia personnel should be familiar with the different components of cuffed and uncuffed tracheostomy devices and their connectivity to the anesthesia circuits. An appropriate airway management plan should take into account the indication of the tracheostomy, the maturity status of the stoma, the type and size of tracheostomy tube, the expected patient positioning, and presence of patient\u2019s concurrent health conditions. Management of the patient with a T-tube is highlighted. Importantly, there is a need for multidisciplinary care involving anesthesiologists, surgical specialists, and perioperative nurses. The aim of this narrative review is to discuss the anesthesia care of patients with a tracheostomy. Key aspects on relevant tracheal anatomy, tracheostomy tubes\/devices, alternatives of airway management, and possible complications related to tracheostomy are summarized with a recommendation for an algorithm to manage intraoperative tracheostomy tube dislodgement.<\/jats:p>","DOI":"10.1213\/ane.0000000000005330","type":"journal-article","created":{"date-parts":[[2020,12,24]],"date-time":"2020-12-24T15:02:13Z","timestamp":1608822133000},"page":"1003-1011","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":21,"title":["Intraoperative Airway Management Considerations for Adult Patients Presenting With Tracheostomy: A Narrative Review"],"prefix":"10.1213","volume":"132","author":[{"given":"Eric B.","family":"Rosero","sequence":"first","affiliation":[{"name":"Paul L. Foster School of Medicine, Texas Tech University Health Sciences Center, El Paso, Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Corbett","sequence":"additional","affiliation":[{"name":"Paul L. Foster School of Medicine, Texas Tech University Health Sciences Center, El Paso, Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ted","family":"Mau","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology-Head and Neck Surgery, University of Texas Southwestern Medical Center, Dallas, Texas."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Girish P.","family":"Joshi","sequence":"additional","affiliation":[{"name":"Paul L. Foster School of Medicine, Texas Tech University Health Sciences Center, El Paso, Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,12,24]]},"reference":[{"key":"R1-20250502","doi-asserted-by":"crossref","first-page":"895","DOI":"10.4187\/respcare.02971","article-title":"Tracheostomy: epidemiology, indications, timing, technique, and outcomes.","volume":"59","author":"Cheung","year":"2014","journal-title":"Respir Care"},{"key":"R2-20250502","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1111\/j.1365-2044.2007.05327.x","article-title":"An investigation into the length of standard tracheostomy tubes in critical care patients.","volume":"63","author":"Mallick","year":"2008","journal-title":"Anaesthesia"},{"key":"R3-20250502","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1177\/0310057X1003800611","article-title":"Vocal cords-carina distance in anaesthetised Caucasian adults and its clinical implications for tracheal intubation.","volume":"38","author":"Pang","year":"2010","journal-title":"Anaesth Intensive Care"},{"key":"R4-20250502","doi-asserted-by":"crossref","first-page":"255","DOI":"10.21037\/acs.2018.03.01","article-title":"Surgical anatomy of the trachea.","volume":"7","author":"Furlow","year":"2018","journal-title":"Ann Cardiothorac Surg"},{"key":"R5-20250502","doi-asserted-by":"crossref","first-page":"903","DOI":"10.2214\/ajr.142.5.903","article-title":"Dimensions of the normal human trachea.","volume":"142","author":"Breatnach","year":"1984","journal-title":"AJR Am J Roentgenol"},{"key":"R6-20250502","first-page":"476","article-title":"Anatomy and physiology of tracheostomy.","volume":"50","author":"Epstein","year":"2005","journal-title":"Respir Care"},{"key":"R7-20250502","doi-asserted-by":"crossref","first-page":"18","DOI":"10.4037\/ccn2013518","article-title":"Tracheostomy care and complications in the intensive care unit.","volume":"33","author":"Morris","year":"2013","journal-title":"Crit Care Nurse"},{"key":"R8-20250502","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1046\/j.1365-2044.2000.01629-16.x","article-title":"Radio-opaque stripes on tracheal and tracheostomy tubes.","volume":"55","author":"Gupta","year":"2000","journal-title":"Anaesthesia"},{"key":"R9-20250502","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1111\/j.1365-2044.2006.04598.x","article-title":"Occlusion of a tracheostomy tube after misinsertion.","volume":"61","author":"Trivedi","year":"2006","journal-title":"Anaesthesia"},{"key":"R10-20250502","first-page":"1661","article-title":"Preliminary report of laryngeal phonation during mechanical ventilation via a new cuffed tracheostomy tube.","volume":"55","author":"Kunduk","year":"2010","journal-title":"Respir Care"},{"key":"R11-20250502","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1093\/bja\/aet236","article-title":"Pneumothorax and cardiac arrest caused by speaking valve mistaken as moisture exchanger: an incident report.","volume":"111","author":"Selleng","year":"2013","journal-title":"Br J Anaesth"},{"key":"R12-20250502","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/S0272-5231(03)00042-X","article-title":"The Montgomery T-tube tracheal stent.","volume":"24","author":"Wahidi","year":"2003","journal-title":"Clin Chest Med"},{"key":"R13-20250502","doi-asserted-by":"crossref","first-page":"3070","DOI":"10.21037\/jtd.2018.05.140","article-title":"Application of the Montgomery T-tube in subglottic tracheal benign stenosis.","volume":"10","author":"Hu","year":"2018","journal-title":"J Thorac Dis"},{"key":"R14-20250502","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1111\/j.1365-2044.2012.07217.x","article-title":"Multidisciplinary guidelines for the management of tracheostomy and laryngectomy airway emergencies.","volume":"67","author":"McGrath","year":"2012","journal-title":"Anaesthesia"},{"key":"R15-20250502","doi-asserted-by":"crossref","first-page":"e119","DOI":"10.1016\/j.bja.2020.04.064","article-title":"Improving tracheostomy care in the United Kingdom: results of a guided quality improvement programme in 20 diverse hospitals.","volume":"125","author":"McGrath","year":"2020","journal-title":"Br J Anaesth"},{"key":"R16-20250502","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/j.thorsurg.2018.03.002","article-title":"Anterior Mediastinal tracheostomy: past, present, and future.","volume":"28","author":"Wurtz","year":"2018","journal-title":"Thorac Surg Clin"},{"key":"R17-20250502","first-page":"800","article-title":"Tracheostomy tube displacement: an update on emergency airway management.","volume":"6","author":"Rajendram","year":"2017","journal-title":"Indian J Respir Care"},{"key":"R18-20250502","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1055\/s-0034-1378186","article-title":"Subcutaneous emphysema following emergent surgical conventional tracheostomy.","volume":"7","author":"Ardekian","year":"2014","journal-title":"Craniomaxillofac Trauma Reconstr"},{"key":"R19-20250502","doi-asserted-by":"crossref","first-page":"1359","DOI":"10.1164\/rccm.2107005","article-title":"The pragmatics of prone positioning.","volume":"165","author":"Messerole","year":"2002","journal-title":"Am J Respir Crit Care Med"},{"key":"R20-20250502","first-page":"735","article-title":"Intraoperative airway obstruction related to tracheostomy tube malposition in a patient with achondroplasia and Jeune\u2019s syndrome.","volume":"20","author":"Abola","year":"2010","journal-title":"Middle East J Anaesthesiol"},{"key":"R21-20250502","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1590\/1806-9282.62.03.287","article-title":"Good practices for prone positioning at the bedside: construction of a care protocol.","volume":"62","author":"Oliveira","year":"2016","journal-title":"Rev Assoc Med Bras (1992)"},{"key":"R23-20250502","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1016\/S0889-8537(05)70245-5","article-title":"Anesthesia for airway surgery.","volume":"19","author":"McRae","year":"2001","journal-title":"Anesthesiol Clin North Am"},{"key":"R24-20250502","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1046\/j.0265-0215.2000.00798.x","article-title":"Use of a metal tracheostomy tube for laser surgery to a subglottic stenosis.","volume":"18","author":"Asai","year":"2001","journal-title":"Eur J Anaesthesiol"},{"key":"R25-20250502","doi-asserted-by":"crossref","first-page":"235","DOI":"10.4103\/0970-9185.94907","article-title":"Tracheal granulation as a cause of unrecognized airway narrowing.","volume":"28","author":"Bhatia","year":"2012","journal-title":"J Anaesthesiol Clin Pharmacol"},{"issue":"suppl","key":"R26-20250502","doi-asserted-by":"crossref","first-page":"S33","DOI":"10.4097\/kjae.2010.59.S.S33","article-title":"Airway management using laryngeal mask airway in insertion of the Montgomery tracheal tube for subglottic stenosis -a case report-.","volume":"59","author":"Park","year":"2010","journal-title":"Korean J Anesthesiol"},{"key":"R27-20250502","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1213\/00000539-199312000-00032","article-title":"Tracheal stents: the Montgomery T-tube.","volume":"77","author":"Mather","year":"1993","journal-title":"Anesth Analg"},{"key":"R28-20250502","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1093\/bja\/87.5.787","article-title":"The Montgomery T-tube: anaesthetic problems and solutions.","volume":"87","author":"Guha","year":"2001","journal-title":"Br J Anaesth"},{"key":"R29-20250502","doi-asserted-by":"crossref","first-page":"105","DOI":"10.4103\/0970-9185.105815","article-title":"Anesthetic management of a patient with Montgomery t-tube in-situ for direct laryngoscopy.","volume":"29","author":"Kerai","year":"2013","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"R30-20250502","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1046\/j.1365-2044.2002.02273.x","article-title":"Removal of obstructing blood clot from the lower airway: an alternative suction technique.","volume":"57","author":"Bodenham","year":"2002","journal-title":"Anaesthesia"},{"key":"R31-20250502","first-page":"106","article-title":"Recommended guide lines for suction.","volume":"70","author":"Young","year":"1984","journal-title":"Physiotherapy"},{"key":"R32-20250502","first-page":"10","article-title":"Problem in tracheostomy patient care: recognizing the patient with a displaced tracheostomy tube.","volume":"15","author":"Seay","year":"1997","journal-title":"ORL Head Neck Nurs"},{"key":"R33-20250502","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1093\/bja\/aer058","article-title":"Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: anaesthesia.","volume":"106","author":"Cook","year":"2011","journal-title":"Br J Anaesth"},{"key":"R34-20250502","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1111\/j.1365-2044.1996.tb12586.x","article-title":"A complication of percutaneous dilatational tracheostomy: mediastinal emphysema.","volume":"51","author":"van Heurn","year":"1996","journal-title":"Anaesthesia"},{"key":"R35-20250502","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1177\/0310057X9902700115","article-title":"Surgical emphysema following percutaneous tracheostomy.","volume":"27","author":"Douglas","year":"1999","journal-title":"Anaesth Intensive Care"},{"key":"R36-20250502","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1016\/j.otohns.2009.09.023","article-title":"Life-threatening tension subcutaneous emphysema as a complication of open tracheostomy.","volume":"142","author":"Showmaker","year":"2010","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R37-20250502","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1177\/175114371101200107","article-title":"National survey of fenestrated versus non-fenestrated tracheostomy tube use and the incidence of surgical emphysema in UK adult intensive care units.","volume":"12","author":"Powell","year":"2011","journal-title":"J Intensive Care Soc"},{"key":"R38-20250502","first-page":"51","article-title":"Ten tips for safer suctioning.","volume":"95","author":"Glass","year":"1995","journal-title":"Am J Nurs"},{"key":"R39-20250502","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1111\/j.1399-6576.1982.tb01715.x","article-title":"Design and function of tracheal suction catheters.","volume":"26","author":"Lomholt","year":"1982","journal-title":"Acta Anaesthesiol Scand"},{"key":"R40-20250502","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/S0272-5231(21)00842-X","article-title":"Tracheostomies. Indications, timing, and complications.","volume":"13","author":"Lewis","year":"1992","journal-title":"Clin Chest Med"},{"key":"R41-20250502","first-page":"104","article-title":"A review of the adverse effects of airway suction.","volume":"70","author":"Young","year":"1984","journal-title":"Physiotherapy"},{"key":"R42-20250502","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1111\/j.1399-6576.2008.01744.x","article-title":"Mask for stoma ventilation: rescue using a Rendell-Baker-Soucek mask after a dislodged tracheostomy tube.","volume":"52","author":"Sharma","year":"2008","journal-title":"Acta Anaesthesiol Scand"},{"key":"R43-20250502","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1177\/014556130408300615","article-title":"Comparison of two face masks used to deliver early ventilation to laryngectomized patients.","volume":"83","author":"Bhalla","year":"2004","journal-title":"Ear Nose Throat J"},{"key":"R44-20250502","first-page":"557","article-title":"Controlled ventilation through a tracheostomy stoma.","volume":"29","author":"Kannan","year":"2001","journal-title":"Anaesth Intensive Care"},{"key":"R45-20250502","first-page":"78","article-title":"Yet another use for the laryngeal mask airway\u2013ventilation of a patient with a tracheostomy stoma.","volume":"29","author":"Padley","year":"2001","journal-title":"Anaesth Intensive Care"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000005330","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:35:04Z","timestamp":1786113304000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000005330"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,24]]},"references-count":44,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000005330","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2020,12,24]]}}}