{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T17:49:42Z","timestamp":1790704182502,"version":"4.1.0"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Some in vivo studies question the traditional \u201cfunnel-shaped\u201d infant larynx; further anatomic examinations were warranted. Examination of fixative free fresh autopsy laryngeal and upper tracheal specimens and multiple measurements was needed to determine consistency between current tracheal tube designs and anatomic observations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>Larynges from 19 males and 11 females (Caucasian term newborn to 126 months) were examined by the same forensic pathologist. Measurements included anterior\/posterior (A\/P) and transverse (T) diameters of the cricoid outlet (CO), interarytenoid diameter (IAD), cricothyroid membrane (CTM), distance from the vocal cords (VC) to CO (VC-CO), and calibration of the larynx lumen with uncuffed tracheal tubes as measuring rods. Assessment of \u201csafe tracheal tube placement\u201d was assessed using manufacturer recommended cuffed Microcuff (Kimberly-Clark, Koblenz, Germany) tubes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>In 77% (95% confidence interval [CI], 58-90) of specimens, the proximal end of the cuff was within the CO and in 23% even with or close to the CO. The VC-CO varied from 9.1 to 13.17 mm in infants, 11.55 to 15.17 mm in toddlers, and 13.19 to 18.34 mm in children. The A-P\/T ratio of the CO was nearly 0.99 in most larynges; the IAD was greater than CO in all specimens. The CTM could be minimally distended in all specimens.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>First, despite being marketed as a safer tracheal tube design, the proximal end of the Microcuff cuff rested within or close to the cricoid cartilage theoretically increasing potential cuff-induced injury when using the VC markings for positioning. Our data suggest that the optimal cuff free distance (VC-CO) would be ~13.5 mm for a Microcuff internal diameter (ID) size 3.0, ~15 mm for size 3.5, and ~16 to 19 mm for greater sizes.<\/jats:p>\n                    <jats:p>Second, the CO was virtually circular in all specimens, suggesting that appropriately sized uncuffed tubes should provide an adequate seal in most neonates and toddlers, thus avoiding the potential for cuff-related necrosis injury.<\/jats:p>\n                    <jats:p>Third, the IAD was always greater than CO confirming that the narrowest point of the infant larynx is the nondistensible cricoid cartilage and not the easily distended glottis.<\/jats:p>\n                    <jats:p>Fourth, appropriately sized Microcuff tubes with the cuff deflated completely filled the lumen of the CO and proximal trachea in all specimens. Our data suggest the need for all manufacturers to further evaluate tracheal tube cuff locations and lengths in relation to the VC safe insertion markings, particularly for neonates and toddlers.<\/jats:p>\n                    <jats:p>Fifth, the CTM is minimally distensible, thus having important implications for emergency surgical airway access with most currently available emergency airway devices.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000005565","type":"journal-article","created":{"date-parts":[[2021,4,26]],"date-time":"2021-04-26T23:26:01Z","timestamp":1619479561000},"page":"894-902","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["Anatomical In Vitro Investigations of the Pediatric Larynx: A Call for Manufacturer Redesign of Tracheal Tube Cuff Location and Perhaps a Call to Reconsider the Use of Uncuffed Tracheal Tubes"],"prefix":"10.1213","volume":"133","author":[{"given":"Malaak","family":"Isa","sequence":"first","affiliation":[{"name":"Institute of Legal Medicine, Medical Faculty, University of Cologne, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josef","family":"Holzki","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Centre Hospitaliere de Li\u00e8ge, Chen\u00e9e, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Hagemeier","sequence":"additional","affiliation":[{"name":"Institute of Medical Statistics and Computational Biology, Medical Faculty, University of Cologne, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Markus A.","family":"Rothschild","sequence":"additional","affiliation":[{"name":"Institute of Legal Medicine, Medical Faculty, University of Cologne, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles J.","family":"Cot\u00e9","sequence":"additional","affiliation":[{"name":"Department of Anesthesia, Mass General Hospital for Children at the Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,4,26]]},"reference":[{"key":"R1-20250502","first-page":"29","article-title":"Tubage du larynx dans le croup.","volume":"6","author":"Bayeux","year":"1897","journal-title":"Presse M\u00e8dicale"},{"key":"R3-20250502","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1097\/00000542-195107000-00001","article-title":"Some anatomic considerations of the infant larynx influencing endotracheal anesthesia.","volume":"12","author":"Eckenhoff","year":"1951","journal-title":"Anesthesiology"},{"key":"R4-20250502","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1097\/00000542-200301000-00010","article-title":"Developmental changes of laryngeal dimensions in unparalyzed, sedated children.","volume":"98","author":"Litman","year":"2003","journal-title":"Anesthesiology"},{"key":"R5-20250502","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1111\/pan.12528","article-title":"Pediatric airway anatomy may not be what we thought: implications for clinical practice and the use of cuffed endotracheal tubes.","volume":"25","author":"Tobias","year":"2015","journal-title":"Paediatr Anaesth"},{"key":"R6-20250502","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1111\/pan.13126","article-title":"Upper airway in infants\u2014a computed tomography-based analysis.","volume":"27","author":"Wani","year":"2017","journal-title":"Paediatr Anaesth"},{"key":"R7-20250502","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1213\/ane.0b013e31819d1d99","article-title":"Pediatric laryngeal dimensions: an age-based analysis.","volume":"108","author":"Dalal","year":"2009","journal-title":"Anesth Analg"},{"key":"R8-20250502","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1111\/pan.13281","article-title":"The anatomy of the pediatric airway: has our knowledge changed in 120 years? A review of historic and recent investigations of the anatomy of the pediatric larynx.","volume":"28","author":"Holzki","year":"2018","journal-title":"Paediatr Anaesth"},{"key":"R9-20250502","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1111\/j.1469-7580.2008.00935.x","article-title":"Prenatal and early postnatal morphogenesis and growth of human laryngotracheal structures.","volume":"213","author":"Fayoux","year":"2008","journal-title":"J Anat"},{"key":"R10-20250502","first-page":"11","article-title":"[Instructions for the complete preparation of the larynx].","volume":"96","author":"Maxeiner","year":"1986","journal-title":"Z Rechtsmed"},{"key":"R11-20250502","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1093\/bja\/aeh294","article-title":"Appropriate placement of intubation depth marks in a new cuffed paediatric tracheal tube.","volume":"94","author":"Weiss","year":"2005","journal-title":"Br J Anaesth"},{"key":"R12-20250502","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1007\/BF03016560","article-title":"Intubation depth markings allow an improved positioning of endotracheal tubes in children.","volume":"52","author":"Weiss","year":"2005","journal-title":"Can J Anaesth"},{"key":"R13-20250502","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1002\/ppul.23232","article-title":"Age-based analysis of pediatric upper airway dimensions using computed tomography imaging.","volume":"51","author":"Wani","year":"2016","journal-title":"Pediatr Pulmonol"},{"issue":"suppl 1","key":"R14-20250502","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1111\/j.1460-9592.2009.03004.x","article-title":"Stridor is not a scientifically valid outcome measure for assessing airway injury.","volume":"19","author":"Holzki","year":"2009","journal-title":"Paediatr Anaesth"},{"key":"R15-20250502","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1016\/j.bja.2018.05.002","article-title":"Tube tip and cuff position using different strategies for placement of currently available paediatric tracheal tubes.","volume":"121","author":"Kemper","year":"2018","journal-title":"Br J Anaesth"},{"key":"R16-20250502","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1111\/pan.13772","article-title":"The development of the cricoid cartilage and its implications for the use of endotracheal tubes in the pediatric population.","volume":"30","author":"Liu","year":"2020","journal-title":"Paediatr Anaesth"},{"key":"R17-20250502","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1111\/pan.13832","article-title":"Developmental changes of upper airway dimensions in children.","volume":"30","author":"Luscan","year":"2020","journal-title":"Paediatr Anaesth"},{"key":"R18-20250502","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1111\/pan.13776","article-title":"Cuffed pediatric endotracheal tubes-outer cuff diameters compared to age-related airway dimensions.","volume":"30","author":"Fischer","year":"2020","journal-title":"Paediatr Anaesth"},{"key":"R19-20250502","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1111\/pan.13210","article-title":"Lower airway dimensions in pediatric patients\u2014a computed tomography study.","volume":"27","author":"Szelloe","year":"2017","journal-title":"Paediatr Anaesth"},{"key":"R20-20250502","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1111\/j.1365-2044.2008.05440.x","article-title":"The impact of head position on the cuff and tube tip position of preformed oral tracheal tubes in young children.","volume":"63","author":"Jordi Ritz","year":"2008","journal-title":"Anaesthesia"},{"key":"R21-20250502","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/S0022-3476(76)80946-8","article-title":"Endotracheal tube displacement in the newborn infant.","volume":"89","author":"Todres","year":"1976","journal-title":"J Pediatr"},{"key":"R22-20250502","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1111\/pan.12066","article-title":"Do lower cuff pressures reduce damage to the tracheal mucosa? A scanning electron microscopy study in neonatal pigs.","volume":"23","author":"Kutter","year":"2013","journal-title":"Paediatr Anaesth"},{"key":"R23-20250502","first-page":"648","article-title":"Injury of cilia induced by tracheal tube cuffs.","volume":"154","author":"Sanada","year":"1982","journal-title":"Surg Gynecol Obstet"},{"key":"R24-20250502","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1177\/000348949210101003","article-title":"Subglottic ulceration and healing following endotracheal intubation in the neonate: a morphometric study.","volume":"101","author":"Gould","year":"1992","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R25-20250502","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1111\/pan.12102","article-title":"Endoscopic airway findings in children with or without prior endotracheal intubation.","volume":"23","author":"Weiss","year":"2013","journal-title":"Paediatr Anaesth"},{"key":"R27-20250502","first-page":"CD011954","article-title":"Cuffed versus uncuffed endotracheal tubes for general anaesthesia in children aged eight years and under.","volume":"11","author":"De Orange","year":"2017","journal-title":"Cochrane Database Syst Rev"},{"issue":"suppl 1","key":"R28-20250502","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1111\/j.1460-9592.2009.02996.x","article-title":"Pediatric transtracheal and cricothyrotomy airway devices for emergency use: which are appropriate for infants and children?","volume":"19","author":"Cot\u00e9","year":"2009","journal-title":"Paediatr Anaesth"},{"key":"R29-20250502","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1111\/pan.13665","article-title":"Pediatric airway dimensions\u2014a summary and presentation of existing data.","volume":"29","author":"Dave","year":"2019","journal-title":"Paediatr Anaesth"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000005565","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:25:53Z","timestamp":1786112753000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000005565"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,26]]},"references-count":27,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000005565","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2021,4,26]]}}}