{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,21]],"date-time":"2026-11-21T12:52:59Z","timestamp":1795265579117,"version":"4.10.3"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,11]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Maneuvers for preventing passive regurgitation of gastric contents are applied to effectively occlude the esophagus throughout rapid sequence induction and intubation. The aim of this randomized, crossover study was to investigate the effectiveness of cricoid and paratracheal pressures in occluding the esophagus through induction of anesthesia and videolaryngoscopy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>After the induction of anesthesia in 40 adult patients, the location of the esophageal entrance relative to the glottis and location of the upper esophagus relative to the trachea at the low paratracheal region were assessed using an ultrasonography, and the outer diameter of the esophagus was measured on ultrasound before and during application of cricoid and paratracheal pressures of 30 N. Then, videolaryngoscopy was performed with the application of each pressure. During videolaryngoscopy, location of the esophageal entrance relative to the glottis under cricoid pressure was examined on the screen of videolaryngoscope, and the upper esophagus under paratracheal pressure was evaluated using ultrasound. The occlusion rate of the esophagus, and the best laryngeal view using the percentage of glottic opening scoring system were also assessed during videolaryngsocopy. Esophageal occlusion under each pressure was determined by inserting an esophageal stethoscope into the esophagus. If the esophageal stethoscope could not be advanced into the esophagus under the application of each pressure, the esophagus was regarded to be occluded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      During videolaryngoscopy, esophagus was occluded in 40 of 40 (100%) patients with cricoid pressure and 23 of 40 (58%) patients with paratracheal pressure (difference, 42%; 95% confidence interval, 26\u201358;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001). Both cricoid and paratracheal pressures significantly decreased the diameter of the esophagus compared to no intervention in the anesthetized paralyzed state (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001, respectively). Ultrasound revealed that the compressed esophagus by paratracheal pressure in the anesthetized paralyzed state was partially released during videolaryngoscopy in 17 of 40 patients, in whom esophageal occlusion was unsuccessful. The best laryngeal view was not significantly different among the no intervention, cricoid pressure, and paratracheal pressure (77 [29] % vs 79 [30] % vs 76 [31] %, respectively;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .064).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>The occlusion of the upper esophagus defined by inability to pass an esophageal stethoscope was more effective with cricoid pressure than with paratracheal pressure during videolaryngoscopy, although both cricoid and paratracheal pressures reduced the diameter of the esophagus on ultrasound in an anesthetized paralyzed state.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000006154","type":"journal-article","created":{"date-parts":[[2022,8,1]],"date-time":"2022-08-01T12:35:46Z","timestamp":1659357346000},"page":"1064-1072","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["Effectiveness of Cricoid and Paratracheal Pressures in Occluding the Upper Esophagus Through Induction of Anesthesia and Videolaryngoscopy: A Randomized, Crossover Study"],"prefix":"10.1213","volume":"135","author":[{"given":"Hyerim","family":"Kim","sequence":"first","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, SMG-SNU Boramae Medical Center, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jee-Eun","family":"Chang","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, SMG-SNU Boramae Medical Center, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dongwook","family":"Won","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, SMG-SNU Boramae Medical Center, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jung-Man","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, SMG-SNU Boramae Medical Center, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tae Kyong","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, SMG-SNU Boramae Medical Center, College of Medicine, Seoul National University, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min Jong","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seong-Won","family":"Min","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, SMG-SNU Boramae Medical Center, College of Medicine, Seoul National University, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin-Young","family":"Hwang","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, SMG-SNU Boramae Medical Center, College of Medicine, Seoul National University, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,8,1]]},"reference":[{"key":"R1-20250502","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/S0140-6736(61)92485-0","article-title":"Cricoid pressure to control regurgitation of stomach contents during induction of anaesthesia.","volume":"2","author":"Sellick","year":"1961","journal-title":"Lancet"},{"key":"R2-20250502","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1097\/ALN.0000000000001489","article-title":"Cricoid pressure controversies: narrative review.","volume":"126","author":"Salem","year":"2017","journal-title":"Anesthesiology"},{"key":"R3-20250502","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1213\/ANE.0000000000000068","article-title":"The effectiveness of cricoid pressure for occluding the esophageal entrance in anesthetized and paralyzed patients: an experimental and observational glidescope study.","volume":"118","author":"Zeidan","year":"2014","journal-title":"Anesth Analg"},{"key":"R4-20250502","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.ijoa.2008.07.006","article-title":"Life-saving or ineffective? An observational study of the use of cricoid pressure and maternal outcome in an African setting.","volume":"18","author":"Fenton","year":"2009","journal-title":"Int J Obstet Anesth"},{"key":"R5-20250502","first-page":"457","article-title":"The application of cricoid pressure. An assessment and a survey of its practice.","volume":"38","author":"Howells","year":"1983","journal-title":"Anaesthesia"},{"key":"R6-20250502","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/0959-289X(92)80005-D","article-title":"Tolerance of cricoid pressure by conscious volunteers.","volume":"1","author":"Vanner","year":"1992","journal-title":"Int J Obstet Anesth"},{"key":"R7-20250502","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1046\/j.1365-2044.1999.00756.x","article-title":"Safe use of cricoid pressure.","volume":"54","author":"Vanner","year":"1999","journal-title":"Anaesthesia"},{"key":"R8-20250502","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1093\/bja\/aew243","article-title":"Cricoid pressure force retention analysis using a simulator.","volume":"117","author":"Komasawa","year":"2016","journal-title":"Br J Anaesth"},{"key":"R9-20250502","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1001\/jamasurg.2018.3577","article-title":"Effect of cricoid pressure compared with a sham procedure in the rapid sequence induction of anesthesia: the IRIS randomized clinical trial.","volume":"154","author":"Birenbaum","year":"2019","journal-title":"JAMA Surg"},{"key":"R10-20250502","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1213\/ANE.0000000000004360","article-title":"The clinical use of cricoid pressure: first, do no harm.","volume":"132","author":"Zdravkovic","year":"2021","journal-title":"Anesth Analg"},{"key":"R11-20250502","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1111\/anae.14442","article-title":"The effect of force applied to the left paratracheal oesophagus on air entry into the gastric antrum during positive-pressure ventilation using a facemask.","volume":"74","author":"Gautier","year":"2019","journal-title":"Anaesthesia"},{"key":"R12-20250502","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1097\/00063110-200508000-00002","article-title":"The 50 ml syringe training aid should be utilized immediately before cricoid pressure application.","volume":"12","author":"Kopka","year":"2005","journal-title":"Eur J Emerg Med"},{"key":"R13-20250502","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1111\/j.1553-2712.1998.tb02823.x","article-title":"Assessment of airway visualization: validation of the percentage of glottic opening (POGO) scale.","volume":"5","author":"Levitan","year":"1998","journal-title":"Acad Emerg Med"},{"key":"R14-20250502","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1111\/anae.14873","article-title":"The effect of cricoid and paralaryngeal force on upper oesophageal occlusion during induction of anaesthesia: a randomised, crossover study.","volume":"75","author":"Kim","year":"2020","journal-title":"Anaesthesia"},{"key":"R15-20250502","doi-asserted-by":"crossref","first-page":"1546","DOI":"10.1213\/ane.0b013e3181b05404","article-title":"Cricoid pressure results in compression of the postcricoid hypopharynx: the esophageal position is irrelevant.","volume":"109","author":"Rice","year":"2009","journal-title":"Anesth Analg"},{"key":"R16-20250502","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1111\/j.1365-2044.2012.07087.x","article-title":"Measurement of forces applied during Macintosh direct laryngoscopy compared with GlideScope videolaryngoscopy.","volume":"67","author":"Russell","year":"2012","journal-title":"Anaesthesia"},{"key":"R17-20250502","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1002\/jcu.20017","article-title":"Sonographic anatomy of the cervical esophagus.","volume":"32","author":"Zhu","year":"2004","journal-title":"J Clin Ultrasound"},{"key":"R18-20250502","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1148\/radiology.214.1.r00dc42237","article-title":"Postcricoid region and cervical esophagus: normal appearance at CT and MR imaging.","volume":"214","author":"Schmalfuss","year":"2000","journal-title":"Radiology"},{"key":"R19-20250502","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1016\/j.annemergmed.2012.10.038","article-title":"Videographic analysis of glottic view with increasing cricoid pressure force.","volume":"61","author":"Oh","year":"2013","journal-title":"Ann Emerg Med"},{"key":"R20-20250502","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1097\/00000542-200502000-00012","article-title":"Cricoid pressure does not increase the rate of failed intubation by direct laryngoscopy in adults.","volume":"102","author":"Turgeon","year":"2005","journal-title":"Anesthesiology"},{"key":"R21-20250502","doi-asserted-by":"crossref","first-page":"896","DOI":"10.1111\/j.1365-2044.1997.181-az0315.x","article-title":"The effect of cricoid pressure and neck support on the view at laryngoscopy.","volume":"52","author":"Vanner","year":"1997","journal-title":"Anaesthesia"},{"key":"R22-20250502","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1213\/ANE.0000000000005620","article-title":"Effect of paratracheal pressure on the glottic view during direct laryngoscopy: a randomized double-blind, noninferiority trial.","volume":"133","author":"Won","year":"2021","journal-title":"Anesth Analg"},{"key":"R23-20250502","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1213\/00000539-199610000-00036","article-title":"Cricoid pressure: teaching the recommended level.","volume":"83","author":"Herman","year":"1996","journal-title":"Anesth Analg"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000006154","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:34:09Z","timestamp":1786113249000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000006154"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,1]]},"references-count":23,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000006154","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2022,8,1]]}}}