{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T10:47:01Z","timestamp":1794307621110,"version":"4.9.0"},"reference-count":78,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:p>Intravenous (IV) fluids and vasopressor agents are key components of hemodynamic management. Since their introduction, their use in the perioperative setting has continued to evolve, and we are now on the brink of automated administration. IV fluid therapy was first described in Scotland during the 1832 cholera epidemic, when pioneers in medicine saved critically ill patients dying from hypovolemic shock. However, widespread use of IV fluids only began in the 20th century. Epinephrine was discovered and purified in the United States at the end of the 19th century, but its short half-life limited its implementation into patient care. Advances in venous access, including the introduction of the central venous catheter, and the ability to administer continuous infusions of fluids and vasopressors rather than just boluses, facilitated the use of fluids and adrenergic agents. With the advent of advanced hemodynamic monitoring, most notably the pulmonary artery catheter, the role of fluids and vasopressors in the maintenance of tissue oxygenation through adequate cardiac output and perfusion pressure became more clearly established, and hemodynamic goals could be established to better titrate fluid and vasopressor therapy. Less invasive hemodynamic monitoring techniques, using echography, pulse contour analysis, and heart-lung interactions, have facilitated hemodynamic monitoring at the bedside. Most recently, advances have been made in closed-loop fluid and vasopressor therapy, which apply computer assistance to interpret hemodynamic variables and therapy. Development and increased use of artificial intelligence will likely represent a major step toward fully automated hemodynamic management in the perioperative environment in the near future. In this narrative review, we discuss the key events in experimental medicine that have led to the current status of fluid and vasopressor therapies and describe the potential benefits that future automation has to offer.<\/jats:p>","DOI":"10.1213\/ane.0000000000006672","type":"journal-article","created":{"date-parts":[[2024,1,12]],"date-time":"2024-01-12T18:00:56Z","timestamp":1705082456000},"page":"284-294","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":10,"title":["Perioperative Fluid and Vasopressor Therapy in 2050: From Experimental Medicine to Personalization Through Automation"],"prefix":"10.1213","volume":"138","author":[{"given":"Sean","family":"Coeckelenbergh","sequence":"first","affiliation":[{"name":"Department of Anesthesiology and Intensive Care, H\u00f4pitaux Universitaires Paris-Saclay, Universit\u00e9 Paris-Saclay, H\u00f4pital Paul-Brousse, Paris, France"},{"name":"Outcomes Research Consortium, Cleveland, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Louis","family":"Vincent","sequence":"additional","affiliation":[{"name":"Department of Intensive Care, Erasme Hospital, Universit\u00e9 Libre de Bruxelles, Brussels, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacques","family":"Duranteau","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Intensive Care, H\u00f4pitaux Universitaires Paris-Saclay, Universit\u00e9 Paris-Saclay, H\u00f4pital Paul-Brousse, Paris, France"},{"name":"Department of Anesthesiology and Intensive Care, H\u00f4pitaux Universitaires Paris-Saclay, Universit\u00e9 Paris-Saclay, H\u00f4pital De Bic\u00eatre, Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandre","family":"Joosten","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Intensive Care, H\u00f4pitaux Universitaires Paris-Saclay, Universit\u00e9 Paris-Saclay, H\u00f4pital Paul-Brousse, Paris, France"},{"name":"Department of Anesthesiology and Intensive Care, H\u00f4pitaux Universitaires Paris-Saclay, Universit\u00e9 Paris-Saclay, H\u00f4pital De Bic\u00eatre, Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph","family":"Rinehart","sequence":"additional","affiliation":[{"name":"Outcomes Research Consortium, Cleveland, Ohio"},{"name":"Department of Anesthesiology & Perioperative Care, University of California, Irvine, California."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,1,12]]},"reference":[{"key":"R2-20250502","article-title":"Injection of saline solutions into the veins, adapted with success in malignant cholera.","author":"Lewins","year":"1832","journal-title":"London Med Gaz"},{"key":"R3-20250502","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1093\/bja\/43.7.681","article-title":"Latta--pioneer in saline infusion.","volume":"43","author":"Masson","year":"1971","journal-title":"Br J Anaesth"},{"key":"R4-20250502","first-page":"271","article-title":"The history of peripheral intravenous catheters: how little plastic tubes revolutionized medicine.","volume":"56","author":"Rivera","year":"2005","journal-title":"Acta Anaesthesiol Belg"},{"key":"R5-20250502","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1126\/science.101.2631.567","article-title":"Intravenous tubing for parenteral therapy.","volume":"101","author":"Zimmermann","year":"1945","journal-title":"Science"},{"key":"R6-20250502","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1213\/00000539-196501000-00005","article-title":"Plastic devices for intravascular therapy.","volume":"44","author":"Martin","year":"1965","journal-title":"Anesth Analg"},{"key":"R7-20250502","first-page":"413","article-title":"A plastic needle.","volume":"25","author":"Massa","year":"1950","journal-title":"Proc Staff Meet Mayo Clin"},{"key":"R8-20250502","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.4065\/83.10.1165","article-title":"The Massa or Rochester plastic needle.","volume":"83","author":"Southorn","year":"2008","journal-title":"Mayo Clin Proc"},{"key":"R9-20250502","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1111\/j.1399-6576.1985.tb02313.x","article-title":"A short history of central venous catheterization.","volume":"81","author":"Kalso","year":"1985","journal-title":"Acta Anaesthesiol Scand Suppl"},{"key":"R10-20250502","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1186\/s12871-020-01128-1","article-title":"Hydroxyethyl starch for perioperative goal-directed fluid therapy in 2020: a narrative review.","volume":"20","author":"Joosten","year":"2020","journal-title":"BMC Anesthesiol"},{"key":"R11-20250502","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1097\/ALN.0000000000001936","article-title":"Crystalloid versus colloid for intraoperative goal-directed fluid therapy using a closed-loop system: a randomized, double-blinded, controlled trial in major abdominal surgery.","volume":"128","author":"Joosten","year":"2018","journal-title":"Anesthesiology"},{"key":"R12-20250502","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1113\/jphysiol.1895.sp000564","article-title":"The physiological effects of extracts of the suprarenal capsules.","volume":"18","author":"Oliver","year":"1895","journal-title":"J Physiol"},{"key":"R13-20250502","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1136\/bmj.320.7233.506","article-title":"\u201cWhere name and image meet\u201d\u2013\u2013the argument for \u201cadrenaline.\u201d","volume":"320","author":"Aronson","year":"2000","journal-title":"BMJ"},{"key":"R14-20250502","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1113\/jphysiol.1895.sp000565","article-title":"On the physiological action of extracts of pituitary body and certain other glandular organs: preliminary communication.","volume":"18","author":"Oliver","year":"1895","journal-title":"J Physiol"},{"key":"R15-20250502","first-page":"55","article-title":"Treatment of shock during an\u00e6sthesia.","volume":"2","author":"Buxton","year":"1909","journal-title":"Proc R Soc Med"},{"key":"R16-20250502","first-page":"1503","article-title":"Intra-arterielle therapie.","author":"Bleichr\u00f6der","year":"1912","journal-title":"Bed Klin Wochenschr"},{"key":"R17-20250502","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1007\/BF01875120","article-title":"Die Sondierung des Rechten Herzens.","volume":"8","author":"Forssmann","year":"1929","journal-title":"Klin Wochenschr"},{"key":"R18-20250502","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1056\/NEJM197008272830902","article-title":"Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter.","volume":"283","author":"Swan","year":"1970","journal-title":"N Engl J Med"},{"key":"R19-20250502","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1097\/00005373-198504000-00005","article-title":"The role of physiologic monitoring in patients with fractures of the hip.","volume":"25","author":"Schultz","year":"1985","journal-title":"J Trauma Inj Infect Crit Care"},{"key":"R20-20250502","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1097\/00003246-197409000-00010","article-title":"Editorial: protocol medicine.","volume":"2","author":"Shoemaker","year":"1974","journal-title":"Crit Care Med"},{"key":"R21-20250502","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1097\/00003246-198811000-00007","article-title":"Tissue oxygen debt as a determinant of lethal and nonlethal postoperative organ failure.","volume":"16","author":"Shoemaker","year":"1988","journal-title":"Crit Care Med"},{"key":"R22-20250502","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1093\/bja\/aen133","article-title":"Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.","volume":"101","author":"Cannesson","year":"2008","journal-title":"Br J Anaesth"},{"key":"R23-20250502","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1001\/archsurg.1995.01430040085019","article-title":"Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery.","volume":"130","author":"Mythen","year":"1995","journal-title":"Arch Surg"},{"key":"R24-20250502","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1097\/00000542-200508000-00026","article-title":"Changes in arterial pressure during mechanical ventilation.","volume":"103","author":"Michard","year":"2005","journal-title":"Anesthesiology"},{"key":"R25-20250502","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1164\/ajrccm.162.1.9903035","article-title":"Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure.","volume":"162","author":"Michard","year":"2000","journal-title":"Am J Respir Crit Care Med"},{"key":"R26-20250502","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/j.bja.2022.12.022","article-title":"Goal-directed haemodynamic therapy: an imprecise umbrella term to avoid.","volume":"130","author":"Saugel","year":"2023","journal-title":"Br J Anaesth"},{"key":"R27-20250502","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1016\/j.bja.2021.10.046","article-title":"Goal-directed haemodynamic therapy during general anaesthesia for noncardiac surgery: a systematic review and meta-analysis.","volume":"128","author":"Jessen","year":"2022","journal-title":"Br J Anaesth"},{"key":"R28-20250502","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/0010-4809(79)90008-9","article-title":"Hypertensive crisis managed by computer controlled infusion of sodium nitroprusside: a model for the closed loop administration of short acting vasoactive agents.","volume":"12","author":"Hammond","year":"1979","journal-title":"Comput Biomed Res"},{"key":"R29-20250502","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1109\/TBME.1981.324822","article-title":"A microcomputer-based fluid infusion system for the resuscitation of burn patients.","volume":"28","author":"Bowman","year":"1981","journal-title":"IEEE Trans Biomed Eng"},{"key":"R30-20250502","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1109\/TBME.1987.326072","article-title":"An adaptive controller for closed-loop management of blood pressure in seriously ill patients.","volume":"34","author":"Packer","year":"1987","journal-title":"IEEE Trans Biomed Eng"},{"key":"R31-20250502","first-page":"164","article-title":"Closed-loop management of blood pressure in critically ill patients.","volume":"8","author":"Mason","year":"1985","journal-title":"Australas Phys Eng Sci Med"},{"key":"R32-20250502","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1097\/00003246-199102000-00009","article-title":"Clinical evaluation of closed-loop control of blood pressure in seriously ill patients.","volume":"19","author":"McKinley","year":"1991","journal-title":"Crit Care Med"},{"key":"R33-20250502","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1007\/s00540-019-02683-9","article-title":"Automated systems for perioperative goal-directed hemodynamic therapy.","volume":"34","author":"Coeckelenbergh","year":"2020","journal-title":"J Anesth"},{"key":"R34-20250502","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1093\/bja\/aeu452","article-title":"Variability in practice and factors predictive of total crystalloid administration during abdominal surgery: retrospective two-centre analysis.","volume":"114","author":"Lilot","year":"2015","journal-title":"Br J Anaesth"},{"key":"R36-20250502","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.bja.2020.04.094","article-title":"Personalised haemodynamic management targeting baseline cardiac index in high-risk patients undergoing major abdominal surgery: a randomised single-centre clinical trial.","volume":"125","author":"Nicklas","year":"2020","journal-title":"Br J Anaesth"},{"key":"R37-20250502","doi-asserted-by":"crossref","first-page":"1346","DOI":"10.1001\/jama.2017.14172","article-title":"Effect of individualized vs standard blood pressure management strategies on postoperative organ dysfunction among high-risk patients undergoing major surgery: a randomized clinical trial.","volume":"10","author":"Futier","year":"2017","journal-title":"JAMA"},{"key":"R38-20250502","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1186\/s13054-021-03464-1","article-title":"Association between perioperative fluid administration and postoperative outcomes: a 20-year systematic review and a meta-analysis of randomized goal-directed trials in major visceral\/noncardiac surgery.","volume":"25","author":"Messina","year":"2021","journal-title":"Crit Care"},{"key":"R39-20250502","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1097\/ALN.0b013e3182a10e26","article-title":"Relationship between intraoperative mean arterial pressure and clinical outcomes after noncardiac surgery: toward an empirical definition of hypotension.","volume":"119","author":"Walsh","year":"2013","journal-title":"Anesthesiology"},{"key":"R40-20250502","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1186\/s12871-020-01228-y","article-title":"Intraoperative hypotension during liver transplant surgery is associated with postoperative acute kidney injury: a historical cohort study.","volume":"21","author":"Joosten","year":"2021","journal-title":"BMC Anesthesiol"},{"key":"R41-20250502","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.accpm.2018.11.009","article-title":"Blood pressure variability in surgical and intensive care patients: Is there a potential for closed-loop vasopressor administration?","volume":"38","author":"Rinehart","year":"2019","journal-title":"Anaesth Crit Care Pain Med"},{"key":"R42-20250502","doi-asserted-by":"crossref","first-page":"R278","DOI":"10.1186\/cc10562","article-title":"Evaluation of a novel closed-loop fluid-administration system based on dynamic predictors of fluid responsiveness: an in silico simulation study.","volume":"15","author":"Rinehart","year":"2011","journal-title":"Crit Care"},{"key":"R43-20250502","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1053\/j.jvca.2012.05.015","article-title":"Intraoperative stroke volume optimization using stroke volume, arterial pressure, and heart rate: closed-loop (learning intravenous resuscitator) versus anesthesiologists.","volume":"26","author":"Rinehart","year":"2012","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R44-20250502","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.1213\/ANE.0b013e3182930050","article-title":"Closed-loop fluid resuscitation: robustness against weight and cardiac contractility variations.","volume":"117","author":"Rinehart","year":"2013","journal-title":"Anesth Analg"},{"key":"R45-20250502","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1213\/ANE.0b013e3182937d61","article-title":"Closed-loop fluid administration compared to anesthesiologist management for hemodynamic optimization and resuscitation during surgery: an in vivo study.","volume":"117","author":"Rinehart","year":"2013","journal-title":"Anesth Analg"},{"key":"R46-20250502","doi-asserted-by":"crossref","first-page":"e35","DOI":"10.1016\/j.annfar.2013.11.016","article-title":"First closed-loop goal directed fluid therapy during surgery: a pilot study.","volume":"33","author":"Rinehart","year":"2014","journal-title":"Ann Fr Anesth Reanim"},{"key":"R47-20250502","doi-asserted-by":"crossref","first-page":"886","DOI":"10.1093\/bja\/aev002","article-title":"Goal-directed fluid therapy with closed-loop assistance during moderate risk surgery using noninvasive cardiac output monitoring: a pilot study.","volume":"114","author":"Joosten","year":"2015","journal-title":"Br J Anaesth"},{"key":"R48-20250502","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1186\/s13054-015-0827-7","article-title":"Closed-loop assisted versus manual goal-directed fluid therapy during high-risk abdominal surgery: a case-control study with propensity matching.","volume":"19(1)","author":"Rinehart","year":"2015","journal-title":"Crit Care"},{"key":"R49-20250502","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1097\/EJA.0000000000000827","article-title":"Implementation of closed-loop-assisted intra-operative goal-directed fluid therapy during major abdominal surgery: a case\u2013control study with propensity matching.","volume":"35","author":"Joosten","year":"2018","journal-title":"Eur J Anaesthesiol"},{"key":"R50-20250502","doi-asserted-by":"crossref","first-page":"e8","DOI":"10.1213\/ANE.0000000000003553","article-title":"Personalized versus protocolized fluid management using noninvasive hemodynamic monitoring (clearsight system) in patients undergoing moderate-risk abdominal surgery.","volume":"129","author":"Joosten","year":"2019","journal-title":"Anesth Analg"},{"key":"R51-20250502","doi-asserted-by":"crossref","first-page":"993","DOI":"10.1007\/s10877-018-0106-7","article-title":"Comparison of cardiac output optimization with an automated closed-loop goal-directed fluid therapy versus non standardized manual fluid administration during elective abdominal surgery: first prospective randomized controlled trial.","volume":"32","author":"Lilot","year":"2018","journal-title":"J Clin Monit Comput"},{"key":"R52-20250502","doi-asserted-by":"crossref","first-page":"1409","DOI":"10.3390\/jpm12091409","article-title":"A pilot study assessing a closed-loop system for goal-directed fluid therapy in abdominal surgery patients.","volume":"12","author":"Gricourt","year":"2022","journal-title":"J Pers Med"},{"key":"R53-20250502","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1007\/s10877-018-0156-x","article-title":"Practical impact of a decision support for goal-directed fluid therapy on protocol adherence: a clinical implementation study in patients undergoing major abdominal surgery.","volume":"33","author":"Joosten","year":"2019","journal-title":"J Clin Monit Comput"},{"key":"R54-20250502","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1097\/ALN.0000000000003790","article-title":"Assisted fluid management software guidance for intraoperative fluid administration.","volume":"135","author":"Maheshwari","year":"2021","journal-title":"Anesthesiology"},{"key":"R55-20250502","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1111\/j.1365-2044.2007.05257.x","article-title":"Closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: a preliminary descriptive study.","volume":"62","author":"Ngan Kee","year":"2007","journal-title":"Anaesthesia"},{"key":"R56-20250502","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1093\/bja\/aes339","article-title":"Randomized comparison of closed-loop feedback computer-controlled with manual-controlled infusion of phenylephrine for maintaining arterial pressure during spinal anaesthesia for caesarean delivery.","volume":"110","author":"Ngan Kee","year":"2013","journal-title":"Br J Anaesth"},{"key":"R57-20250502","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1213\/ANE.0000000000001974","article-title":"Closed-loop feedback computer-controlled phenylephrine for maintenance of blood pressure during spinal anesthesia for cesarean delivery: a randomized trial comparing automated boluses versus infusion.","volume":"125","author":"Ngan Kee","year":"2017","journal-title":"Anesth Analg"},{"key":"R58-20250502","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1007\/s10877-016-9883-z","article-title":"Performance of a closed-loop feedback computer-controlled infusion system for maintaining blood pressure during spinal anaesthesia for caesarean section: a randomized controlled comparison of norepinephrine versus phenylephrine.","volume":"31","author":"Ngan Kee","year":"2017","journal-title":"J Clin Monit Comput"},{"key":"R59-20250502","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1007\/s10877-017-9981-6","article-title":"Feasibility of automated titration of vasopressor infusions using a novel closed-loop controller.","volume":"32","author":"Rinehart","year":"2018","journal-title":"J Clin Monit Comput"},{"key":"R60-20250502","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1007\/s10877-021-00761-6","article-title":"In-silico analysis of closed-loop vasopressor control of phenylephrine versus norepinephrine.","volume":"36","author":"Ma","year":"2022","journal-title":"J Clin Monit Comput"},{"key":"R61-20250502","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1097\/ALN.0000000000002581","article-title":"Automated titration of vasopressor infusion using a closed-loop controller: in vivo feasibility study using a swine model.","volume":"130","author":"Joosten","year":"2019","journal-title":"Anesthesiology"},{"key":"R62-20250502","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1016\/j.bja.2019.04.064","article-title":"Feasibility of closed-loop titration of norepinephrine infusion in patients undergoing moderate- and high-risk surgery.","volume":"123","author":"Joosten","year":"2019","journal-title":"Br J Anaesth"},{"key":"R63-20250502","doi-asserted-by":"crossref","first-page":"3081","DOI":"10.1053\/j.jvca.2020.03.038","article-title":"Closed-loop control of vasopressor administration in patients undergoing cardiac revascularization surgery.","volume":"34","author":"Rinehart","year":"2020","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R64-20250502","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1016\/j.accpm.2019.12.011","article-title":"Feasibility of computer-assisted vasopressor infusion using continuous non-invasive blood pressure monitoring in high-risk patients undergoing renal transplant surgery.","volume":"39","author":"Joosten","year":"2020","journal-title":"Anaesth Crit Care Pain Med"},{"key":"R65-20250502","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.bja.2020.08.051","article-title":"Automated closed-loop versus manually controlled norepinephrine infusion in patients undergoing intermediate- to high-risk abdominal surgery: a randomised controlled trial.","volume":"126","author":"Joosten","year":"2021","journal-title":"Br J Anaesth"},{"key":"R66-20250502","doi-asserted-by":"crossref","first-page":"964","DOI":"10.1213\/ANE.0000000000005888","article-title":"Control of postoperative hypotension using a closed-loop system for norepinephrine infusion in patients after cardiac surgery: a randomized trial.","volume":"134","author":"Desebbe","year":"2022","journal-title":"Anesth Analg"},{"key":"R67-20250502","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1097\/00000542-200604000-00012","article-title":"Titration of propofol for anesthetic induction and maintenance guided by the bispectral index: closed-loop versus manual control. A prospective, randomized, multicenter study.","volume":"104","author":"Liu","year":"2006","journal-title":"Anesthesiology"},{"key":"R68-20250502","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1213\/ANE.0b013e318205680b","article-title":"Closed-loop coadministration of propofol and remifentanil guided by bispectral index: a randomized multicenter study.","volume":"112","author":"Liu","year":"2011","journal-title":"Anesth Analg"},{"key":"R69-20250502","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1093\/bja\/aet001","article-title":"Evaluation of a novel closed-loop total intravenous anaesthesia drug delivery system: a randomized controlled trial.","volume":"110","author":"Hemmerling","year":"2013","journal-title":"Br J Anaesth"},{"key":"R70-20250502","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1213\/XAA.0000000000000405","article-title":"Fully automated anesthesia and fluid management using multiple physiologic closed-loop systems in a patient undergoing high-risk surgery.","volume":"7","author":"Joosten","year":"2016","journal-title":"A A Case Rep"},{"key":"R71-20250502","doi-asserted-by":"crossref","first-page":"e88","DOI":"10.1213\/ANE.0000000000003433","article-title":"Feasibility of fully automated hypnosis, analgesia, and fluid management using 2 independent closed-loop systems during major vascular surgery.","volume":"128","author":"Joosten","year":"2019","journal-title":"Anesth Analg"},{"key":"R72-20250502","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1097\/ALN.0000000000003014","article-title":"Anesthetic management using multiple closed-loop systems and delayed neurocognitive recovery: a randomized controlled trial.","volume":"132","author":"Joosten","year":"2020","journal-title":"Anesthesiology"},{"key":"R73-20250502","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1097\/ALN.0000000000003807","article-title":"Computer-assisted individualized hemodynamic management reduces intraoperative hypotension in intermediate- and high-risk surgery: a randomized controlled trial.","volume":"135","author":"Joosten","year":"2021","journal-title":"Anesthesiology"},{"key":"R74-20250502","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1186\/s12871-017-0437-9","article-title":"Computer-controlled closed-loop drug infusion system for automated hemodynamic resuscitation in endotoxin-induced shock.","volume":"17","author":"Uemura","year":"2017","journal-title":"BMC Anesthesiol"},{"key":"R75-20250502","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1186\/s13613-018-0436-0","article-title":"Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study.","volume":"8","author":"Libert","year":"2018","journal-title":"Ann Intensive Care"},{"key":"R76-20250502","doi-asserted-by":"crossref","first-page":"1699","DOI":"10.1109\/TBME.2015.2499782","article-title":"Less invasive approach to automated closed-loop control of hemodynamics in decompensated heart failure.","volume":"63(8)","author":"Uemura","year":"2016","journal-title":"IEEE Trans Biomed Eng"},{"key":"R77-20250502","doi-asserted-by":"crossref","first-page":"1120","DOI":"10.1213\/ANE.0000000000004646","article-title":"Autonomous systems in anesthesia: where do we stand in 2020? A narrative review.","volume":"130","author":"Zaouter","year":"2020","journal-title":"Anesth Analg"},{"key":"R78-20250502","doi-asserted-by":"crossref","first-page":"5908","DOI":"10.1038\/s41598-023-33027-z","article-title":"Avatar-based patient monitoring improves information transfer, diagnostic confidence and reduces perceived workload in intensive care units: computer-based, multicentre comparison study.","volume":"13","author":"Bergauer","year":"2023","journal-title":"Sci Rep"},{"key":"R79-20250502","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1016\/j.bja.2018.04.024","article-title":"Using an animated patient avatar to improve perception of vital sign information by anaesthesia professionals.","volume":"121","author":"Tscholl","year":"2018","journal-title":"Br J Anaesth"},{"key":"R80-20250502","doi-asserted-by":"crossref","first-page":"1716","DOI":"10.1038\/s41591-018-0213-5","article-title":"The artificial intelligence clinician learns optimal treatment strategies for sepsis in intensive care.","volume":"24","author":"Komorowski","year":"2018","journal-title":"Nat Med"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000006672","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:31:56Z","timestamp":1786113116000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000006672"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,12]]},"references-count":78,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000006672","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2024,1,12]]}}}