{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T17:29:30Z","timestamp":1793726970181,"version":"4.6.1"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,7]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Large neck circumference and displacement of the trachea due to pathology increase the risk of failed identification of the cricothyroid membrane and cricothyroidotomy. We investigated whether ultrasound aids in the successful identification of the cricothyroid membrane in a model of an obese neck with midline deviation of the trachea.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>We developed silicone neck models that were suitable for both palpation and ultrasonography and where the trachea deviated laterally from the midline to either side. After reading a book chapter and participating in a 25-minute lecture and a 15- to 23-minute hands-on demonstration and rehearsal of ultrasonography for identification of the cricothyroid membrane, anesthesiologists and anesthesiology residents randomly performed identification with either ultrasound or palpation on 1 of 2 neck models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>We included 57 participants, of whom 29 and 28 were randomized to palpation and ultrasound, respectively. Correct identification of the cricothyroid membrane was achieved by 21 (75.0%) vs 1 (3.5%) of participants in the ultrasound versus palpation groups (risk ratio [RR], 21.8 [95% confidence interval {CI}, 3.1\u2013151.0]). The tracheal midline position in the sagittal plane was identified correctly by 24 (85.7%) vs 16 (55.2%) of participants in the ultrasound versus palpation groups (RR, 1.6 [95% CI, 1.1\u20132.2]).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Identification of the cricothyroid membrane in a model of an obese neck with midline deviation of the trachea was more often successful with ultrasound compared to palpation. Our study supports the potential use of ultrasound before induction of anesthesia and airway management in this group of patients, and it may even be applied in emergency situations when ultrasound is readily available. Further studies in human subjects should be conducted.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000006867","type":"journal-article","created":{"date-parts":[[2024,1,31]],"date-time":"2024-01-31T14:00:43Z","timestamp":1706709643000},"page":"195-200","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Palpation Versus Ultrasonography for Identifying the Cricothyroid Membrane in Case of a Laterally Deviated Larynx: A Randomized Trial"],"prefix":"10.1213","volume":"139","author":[{"given":"Robin","family":"Lohse","sequence":"first","affiliation":[{"name":"From the Department of Anaesthesiology, Centre of Head and Orthopaedics, Copenhagen University Hospital, Copenhagen, Denmark."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nanna","family":"Wagner","sequence":"additional","affiliation":[{"name":"From the Department of Anaesthesiology, Centre of Head and Orthopaedics, Copenhagen University Hospital, Copenhagen, Denmark."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael Seltz","family":"Kristensen","sequence":"additional","affiliation":[{"name":"From the Department of Anaesthesiology, Centre of Head and Orthopaedics, Copenhagen University Hospital, Copenhagen, Denmark."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,1,31]]},"reference":[{"key":"R1-20250502","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1093\/bja\/aev371","article-title":"Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults.","volume":"115","author":"Frerk","year":"2015","journal-title":"Br J Anaesth"},{"key":"R2-20250502","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1007\/s12630-021-02007-0","article-title":"Canadian Airway Focus Group updated consensus-based recommendations for management of the difficult airway: part 1. Difficult airway management encountered in an unconscious patient.","volume":"68","author":"Law","year":"2021","journal-title":"Can J Anaesth"},{"key":"R3-20250502","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1093\/bja\/aer058","article-title":"Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: anaesthesia.","volume":"106","author":"Cook","year":"2011","journal-title":"Br J Anaesth"},{"key":"R4-20250502","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1007\/s12630-015-0326-y","article-title":"Accuracy of identifying the cricothyroid membrane by anesthesia trainees and staff in a Canadian institution.","volume":"62","author":"Lamb","year":"2015","journal-title":"Can J Anaesth"},{"key":"R5-20250502","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1007\/s12630-016-0647-5","article-title":"Comparing success rates of anesthesia providers versus trauma surgeons in their use of palpation to identify the cricothyroid membrane in female subjects: a prospective observational study.","volume":"63","author":"Hiller","year":"2016","journal-title":"Can J Anaesth"},{"key":"R6-20250502","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1111\/j.1365-2044.2010.06425.x","article-title":"Accuracy of surface landmark identification for cannula cricothyroidotomy.","volume":"65","author":"Elliott","year":"2010","journal-title":"Anaesthesia"},{"key":"R7-20250502","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1213\/ANE.0b013e31824970ba","article-title":"Accuracy of identification of the cricothyroid membrane in female subjects using palpation: an observational study.","volume":"114","author":"Aslani","year":"2012","journal-title":"Anesth Analg"},{"key":"R8-20250502","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1097\/ALN.0000000000002454","article-title":"Ultrasound is superior to palpation in identifying the cricothyroid membrane in subjects with poorly defined neck landmarks.","volume":"129","author":"Siddiqui","year":"2018","journal-title":"Anesthesiology"},{"key":"R9-20250502","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1007\/s43678-022-00399-6","article-title":"Role of ultrasonography in an impalpable tissue larynx model during a simulated front-of-neck access scenario: a randomized simulation study.","volume":"24","author":"Zasso","year":"2022","journal-title":"CJEM"},{"key":"R10-20250502","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1111\/anae.13167","article-title":"Accuracy of conventional digital palpation and ultrasound of the cricothyroid membrane in obese women in labour.","volume":"70","author":"You-Ten","year":"2015","journal-title":"Anaesthesia"},{"key":"R11-20250502","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1093\/bja\/aev123","article-title":"Structured approach to ultrasound-guided identification of the cricothyroid membrane: a randomized comparison with the palpation method in the morbidly obese.","volume":"114","author":"Kristensen","year":"2015","journal-title":"Br J Anaesth"},{"key":"R12-20250502","doi-asserted-by":"crossref","first-page":"e9","DOI":"10.1016\/j.bja.2020.08.012","article-title":"Comparison between ultrasound-guided and digital palpation techniques for identification of the cricothyroid membrane: a meta-analysis.","volume":"126","author":"Hung","year":"2021","journal-title":"Br J Anaesth"},{"key":"R13-20250502","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1097\/ALN.0000000000000848","article-title":"Ultrasound improves cricothyrotomy success in cadavers with poorly defined neck anatomy: a randomized control trial.","volume":"123","author":"Siddiqui","year":"2015","journal-title":"Anesthesiology"},{"key":"R15-20250502","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.1111\/j.1399-6576.2011.02518.x","article-title":"Ultrasonography in the management of the airway.","volume":"55","author":"Kristensen","year":"2011","journal-title":"Acta Anaesthesiol Scand"},{"key":"R16-20250502","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1111\/aas.13464","article-title":"Depth to the airway lumen at the level of the cricothyroid membrane measured by ultrasound.","volume":"64","author":"Athanassoglou","year":"2020","journal-title":"Acta Anaesthesiol Scand"},{"key":"R17-20250502","doi-asserted-by":"crossref","first-page":"c332","DOI":"10.1136\/bmj.c332","article-title":"CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials.","volume":"340","author":"Schulz","year":"2010","journal-title":"BMJ"},{"key":"R18-20250502","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1097\/00000539-200203000-00047","article-title":"Morbid obesity and tracheal intubation.","volume":"94","author":"Brodsky","year":"2002","journal-title":"Anesth Analg"},{"key":"R19-20250502","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1097\/EJA.0b013e32833d91aa","article-title":"Airway management and morbid obesity.","volume":"27","author":"Kristensen","year":"2010","journal-title":"Eur J Anaesthesiol"},{"key":"R20-20250502","doi-asserted-by":"crossref","first-page":"1422","DOI":"10.1111\/aas.13680","article-title":"A marking of the cricothyroid membrane with extended neck returns to correct position after neck manipulation and repositioning.","volume":"64","author":"Bowness","year":"2020","journal-title":"Acta Anaesthesiol Scand"},{"key":"R21-20250502","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1111\/anae.13465","article-title":"A randomised cross-over comparison of the transverse and longitudinal techniques for ultrasound-guided identification of the cricothyroid membrane in morbidly obese subjects.","volume":"71","author":"Kristensen","year":"2016","journal-title":"Anaesthesia"},{"key":"R22-20250502","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1002\/(SICI)1098-2353(1996)9:5<291::AID-CA1>3.0.CO;2-G","article-title":"The dimensions and vascular anatomy of the cricothyroid membrane: relevance to emergent surgical airway access.","volume":"9","author":"Dover","year":"1996","journal-title":"Clin Anat"},{"key":"R23-20250502","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1002\/ca.10231","article-title":"Cricothyroidotomy: a clinical anatomy review.","volume":"17","author":"Boon","year":"2004","journal-title":"Clin Anat"},{"key":"R24-20250502","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1016\/j.bja.2018.07.013","article-title":"Prevalence of major vessels anterior to the trachea at sites of potential front-of-neck emergency airway access in adults.","volume":"121","author":"Weightman","year":"2018","journal-title":"Br J Anaesth"},{"key":"R25-20250502","first-page":"e37164","article-title":"Transillumination and point-of-care ultrasonography to delineate tracheal deviation for challenging tracheostomy: a case report.","volume":"15","author":"Arora","year":"2023","journal-title":"Cureus"},{"key":"R26-20250502","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1213\/ANE.0000000000003604","article-title":"Practice of ultrasound-guided palpation of neck landmarks improves accuracy of external palpation of the cricothyroid membrane.","volume":"127","author":"You-Ten","year":"2018","journal-title":"Anesth Analg"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000006867","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:32:32Z","timestamp":1786113152000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000006867"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,31]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000006867","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2024,1,31]]}}}