{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T20:10:25Z","timestamp":1791490225030,"version":"4.3.4"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>\n                      Mixed venous oxygen saturation (SvO\n                      <jats:sub>2<\/jats:sub>\n                      ) is a critical variable in the assessment of oxygen supply and demand but is rarely used in children due to the invasive nature of pulmonary artery catheters. The aim of this prospective, observational study was to investigate the accuracy of noninvasively measured SvO\n                      <jats:sub>2<\/jats:sub>\n                      acquired by the novel capnodynamic method, based on differential Fick equation (Capno-SvO\n                      <jats:sub>2<\/jats:sub>\n                      ), against gold standard CO-oximetry.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>\n                      Capno-SvO\n                      <jats:sub>2<\/jats:sub>\n                      was compared to SvO\n                      <jats:sub>2<\/jats:sub>\n                      measured by pulmonary artery blood gas CO-oximetry in children undergoing cardiac catheter interventions and subjected to moderate hemodynamic challenges. Bland-Altman analysis was used to describe the agreement of absolute values between CO-oximetry and Capno-SvO\n                      <jats:sub>2<\/jats:sub>\n                      , and a concordance rate was calculated to evaluate the ability of Capno-SvO\n                      <jats:sub>2<\/jats:sub>\n                      to track change.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Twenty-five procedures were included in the study. Capno-SvO\n                      <jats:sub>2<\/jats:sub>\n                      showed a bias toward CO-oximetry of +3 percentage points; upper and lower limits of agreement were +11 percentage points (95% confidence interval [CI], 9\u201314) and \u22125 percentage points (95% CI, \u22128 to \u22123), respectively. The concordance rate was 92% (95% CI, 89\u201396).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>\n                      In conclusion, this first clinical application of a novel concept for noninvasive SvO\n                      <jats:sub>2<\/jats:sub>\n                      monitoring without the need for a pulmonary artery catheter indicates that Capno-SvO\n                      <jats:sub>2<\/jats:sub>\n                      generates absolute values and trending capacity in close agreement with the gold standard reference method.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000007083","type":"journal-article","created":{"date-parts":[[2024,8,2]],"date-time":"2024-08-02T13:46:23Z","timestamp":1722606383000},"page":"781-788","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Validation of a Novel Method for Noninvasive Mixed Venous Oxygen Saturation Monitoring in Anesthetized Children"],"prefix":"10.1213","volume":"139","author":[{"given":"Anders","family":"Svedmyr","sequence":"first","affiliation":[{"name":"Department of Physiology and Pharmacology (FYFA), C3, Eriksson I Lars, PA L\u00f6nnqvist Group, Section of Anesthesiology and Intensive Care, Karolinska Institute, Stockholm, Sweden"},{"name":"Department of Pediatric Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kristoffer","family":"Steiner","sequence":"additional","affiliation":[{"name":"Department of Pediatric Cardiology, Karolinska University Hospital, Stockholm, Sweden"},{"name":"Department of Women\u2019s and Children\u2019s Health, Karolinska Institute, Stockholm, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Andersson","sequence":"additional","affiliation":[{"name":"Department of Physiology and Pharmacology (FYFA), C3, Eriksson I Lars, PA L\u00f6nnqvist Group, Section of Anesthesiology and Intensive Care, Karolinska Institute, Stockholm, Sweden"},{"name":"Department of Pediatric Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gunnar","family":"Sj\u00f6berg","sequence":"additional","affiliation":[{"name":"Department of Pediatric Cardiology, Karolinska University Hospital, Stockholm, Sweden"},{"name":"Department of Women\u2019s and Children\u2019s Health, Karolinska Institute, Stockholm, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Magnus","family":"Hallb\u00e4ck","sequence":"additional","affiliation":[{"name":"Maquet Critical Care AB, Solna, Sweden."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mats","family":"Wallin","sequence":"additional","affiliation":[{"name":"Department of Physiology and Pharmacology (FYFA), C3, Eriksson I Lars, PA L\u00f6nnqvist Group, Section of Anesthesiology and Intensive Care, Karolinska Institute, Stockholm, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Per-Arne","family":"L\u00f6nnqvist","sequence":"additional","affiliation":[{"name":"Department of Physiology and Pharmacology (FYFA), C3, Eriksson I Lars, PA L\u00f6nnqvist Group, Section of Anesthesiology and Intensive Care, Karolinska Institute, Stockholm, Sweden"},{"name":"Department of Pediatric Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacob","family":"Karlsson","sequence":"additional","affiliation":[{"name":"Department of Physiology and Pharmacology (FYFA), C3, Eriksson I Lars, PA L\u00f6nnqvist Group, Section of Anesthesiology and Intensive Care, Karolinska Institute, Stockholm, Sweden"},{"name":"Department of Pediatric Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,8,2]]},"reference":[{"key":"R1-20250502","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1093\/bja\/aer166","article-title":"Mixed venous oxygen saturation predicts short- and long-term outcome after coronary artery bypass grafting surgery: a retrospective cohort analysis.","volume":"107","author":"Holm","year":"2011","journal-title":"Br J Anaesth"},{"key":"R2-20250502","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s10877-021-00673-5","article-title":"The contemporary pulmonary artery catheter. Part 2: measurements, limitations, and clinical applications.","volume":"36","author":"Bootsma","year":"2022","journal-title":"J Clin Monit Comput"},{"key":"R3-20250502","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1002\/ccd.24392","article-title":"Iatrogenic pulmonary artery rupture during Swan-Ganz catheter placement\u2014a novel therapeutic approach.","volume":"81","author":"Kalra","year":"2013","journal-title":"Catheter Cardiovasc Interv"},{"issue":"Suppl 3","key":"R4-20250502","doi-asserted-by":"crossref","first-page":"S8","DOI":"10.1186\/cc4834","article-title":"Evidence-based review of the use of the pulmonary artery catheter: impact data and complications.","volume":"10","author":"Hadian","year":"2006","journal-title":"Crit Care"},{"key":"R5-20250502","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1111\/pan.14328","article-title":"Blood pressure and flow in pediatric anesthesia: an educational review.","volume":"32","author":"Karlsson","year":"2022","journal-title":"Paediatr Anaesth"},{"key":"R6-20250502","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1097\/ALN.0000000000004828","article-title":"Effect of extracerebral contamination on near-infrared spectroscopy as revealed during organ donation: a prospective observational study in brain-dead organ donors.","volume":"140","author":"Soehle","year":"2024","journal-title":"Anesthesiology"},{"key":"R7-20250502","doi-asserted-by":"crossref","first-page":"1768","DOI":"10.1213\/ANE.0000000000005188","article-title":"A continuous noninvasive method to assess mixed venous oxygen saturation: a proof-of-concept study in pigs.","volume":"132","author":"Karlsson","year":"2020","journal-title":"Anesth Analg"},{"issue":"5","key":"R8-20250502","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1007\/s10877-021-00762-5","article-title":"Non-invasive capnodynamic mixed venous oxygen saturation during major changes in oxygen delivery.","volume":"36","author":"Svedmyr","year":"2022","journal-title":"J Clin Monit Comput"},{"key":"R9-20250502","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1111\/pan.14804","article-title":"Capnodynamic end-expiratory lung volume assessment in anesthetized healthy children.","volume":"34","author":"Lundquist","year":"2023","journal-title":"Paediatr Anaesth"},{"key":"R10-20250502","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1186\/s12871-019-0699-5","article-title":"New generation continuous cardiac output monitoring from carbon dioxide elimination.","volume":"19","author":"Peyton","year":"2019","journal-title":"BMC Anesthesiol"},{"key":"R11-20250502","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1023\/A:1021232624767","article-title":"Pulmonary blood flow (cardiac output) and the effective lung volume determined from a short breath hold using the differential Fick method.","volume":"17","author":"Gedeon","year":"2002","journal-title":"J Clin Monit Comput"},{"key":"R12-20250502","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1093\/bja\/aet486","article-title":"Novel continuous capnodynamic method for cardiac output assessment during mechanical ventilation.","volume":"112","author":"H\u00e4llsj\u00f6 Sander","year":"2014","journal-title":"Br J Anaesth"},{"key":"R13-20250502","first-page":"290","article-title":"Uber die messung des Blutquantums in den Hertzvent rikeln.","author":"Fick","year":"1870","journal-title":"Sitzber Physik Med Ges Wurzburg"},{"key":"R14-20250502","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1034\/j.1399-6576.1999.430310.x","article-title":"Intraoperative glucose administration influences respiratory quotient during paediatric anaesthesia.","volume":"43","author":"Sandstr\u00f6m","year":"1999","journal-title":"Acta Anaesthesiol Scand"},{"key":"R15-20250502","doi-asserted-by":"crossref","first-page":"\/j\/ijb.2016.12.issue","DOI":"10.1515\/ijb-2015-0039","article-title":"Sample size for assessing agreement between two methods of measurement by Bland-Altman method.","volume":"12","author":"Lu","year":"2016","journal-title":"Int J Biostat"},{"key":"R16-20250502","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1186\/cc7129","article-title":"Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies\u2014with specific reference to the measurement of cardiac output.","volume":"13","author":"Cecconi","year":"2009","journal-title":"Crit Care"},{"key":"R17-20250502","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement.","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"R18-20250502","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1080\/10543400701329422","article-title":"Agreement between methods of measurement with multiple observations per individual.","volume":"17","author":"Bland","year":"2007","journal-title":"J Biopharm Stat"},{"key":"R19-20250502","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1177\/0962280211402548","article-title":"Confidence interval estimation for the Bland-Altman limits of agreement with multiple observations per individual.","volume":"22","author":"Zou","year":"2013","journal-title":"Stat Methods Med Res"},{"key":"R20-20250502","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1093\/bja\/aet220","article-title":"Reliability of lithium dilution cardiac output in anaesthetized sheep.","volume":"111","author":"Axiak Flammer","year":"2013","journal-title":"Br J Anaesth"},{"key":"R21-20250502","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1213\/ANE.0000000000005679","article-title":"Cardiac output assessments in anesthetized children: dynamic capnography versus esophageal Doppler.","volume":"134","author":"Karlsson","year":"2021","journal-title":"Anesth Analg"},{"key":"R22-20250502","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1111\/aas.12559","article-title":"A novel continuous capnodynamic method for cardiac output assessment in a porcine model of lung lavage.","volume":"59","author":"H\u00e4llsj\u00f6 Sander","year":"2015","journal-title":"Acta Anaesthesiol Scand"},{"key":"R23-20250502","doi-asserted-by":"crossref","first-page":"e0192073","DOI":"10.1371\/journal.pone.0192073","article-title":"Accuracy and precision of ScvO2 measured with the CeVOX-device: a prospective study in patients with a wide variation of ScvO2-values.","volume":"13","author":"Herner","year":"2018","journal-title":"PLoS One"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000007083","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:30:35Z","timestamp":1786113035000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000007083"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,2]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000007083","relation":{},"ISSN":["0003-2999","1526-7598"],"issn-type":[{"value":"0003-2999","type":"print"},{"value":"1526-7598","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,2]]}}}