{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T16:45:13Z","timestamp":1795020313039,"version":"4.10.1"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>The Society for Obstetric Anesthesia and Perinatology (SOAP) recommends monitoring for respiratory depression after cesarean delivery according to intrathecal morphine (ITM) dose. The aim of the study was to compare respiratory metrics after ITM administration, to determine evidence for the SOAP recommendations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>\n                      Prospective observational cohort study design. Following institutional review board approval, women undergoing non-emergency cesarean delivery with spinal anesthesia in a single center were enrolled. Women were offered 50 \u00b5g, 150 \u00b5g or transversus abdominis plane (TAP) block without ITM, for postoperative analgesia. Respiratory monitoring, continuous acoustic respiratory rate (RR) and pulse oximetry oxygen saturation (SpO\n                      <jats:sub>2<\/jats:sub>\n                      ) monitor Masimo Radius-7, was used after surgery up to 12 hours postoperatively. The primary outcome was bradypnea, number of women with RR \u2264 8 breaths per minute according to dose.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Among 80 recruits, 33 (41%) chose 50 \u00b5g, 46 (57%) chose 150 \u00b5g, and one chose TAP block. Bradypnea events were detected 564 times among 27 (81.8%) women receiving 50 \u00b5g and 529 times among 40 (87.0%) women receiving 150 \u00b5g. Median [interquartile range (IQR)] duration of bradypnea per patient was 1.58 [1.15\u20132.42] in 50 \u00b5g group and 1.09 [0.83\u20131.70] in 150 \u00b5g group,\n                      <jats:italic toggle=\"yes\">P &lt;<\/jats:italic>\n                      .001. The event rate of bradypnea was 1.89 (95% confidence intervals [CIs], 1.73\u20132.05) events per person-hour among women receiving 50 \u00b5g versus 1.23 (95% CI, 1.12\u20131.34) events per person-hour among women receiving 150 \u00b5g,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .624. Most, 62% of bradypnea occurred by 6 hours, and 86% of events by 12 hours. Apnea and hypoxemia event rates were similar, but hypoxemia duration was significantly prolonged after 150 \u00b5g, median 48 [IQR, 36\u201390] versus 56 sec [IQR, 40\u2013106];\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .001. Nursing assessments done per institutional protocol did not identify any respiratory events. No woman required oxygen or naloxone administration.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>We found no statistically significant differences in RR comparing 50 and 150 \u00b5g ITM, using continuous monitoring. Although the 150 \u00b5g group experienced a higher incidence of hypoxemia events, these were not clinically significant.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000007908","type":"journal-article","created":{"date-parts":[[2026,3,5]],"date-time":"2026-03-05T23:00:08Z","timestamp":1772751608000},"page":"113-121","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Prospective Study of Postoperative Respiratory Depression Metrics After Cesarean Delivery Among Women Receiving Intrathecal Morphine"],"prefix":"10.1213","volume":"143","author":[{"given":"Adam","family":"Lustig","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Intensive Care, and Pain, Tel Aviv Sourasky Medical Center affiliated with the Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brendan","family":"Carvalho","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Stanford, California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shimon","family":"Haim","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Intensive Care, and Pain, Tel Aviv Sourasky Medical Center affiliated with the Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nan","family":"Guo","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Stanford, California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chaim","family":"Greenberger","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Intensive Care, and Pain, Tel Aviv Sourasky Medical Center affiliated with the Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dana","family":"Karol","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Schneider Children\u2019s Hospital, Petach Tikva affiliated with the Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv, Israel."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boris","family":"Aptekman","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Intensive Care, and Pain, Tel Aviv Sourasky Medical Center affiliated with the Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carolyn F.","family":"Weiniger","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Intensive Care, and Pain, Tel Aviv Sourasky Medical Center affiliated with the Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,3,5]]},"reference":[{"key":"R1-20260617","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.anclin.2016.09.010","article-title":"Optimal pain management after cesarean delivery.","volume":"35","author":"Sutton","year":"2017","journal-title":"Anesthesiol Clin"},{"key":"R2-20260617","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1097\/ALN.0000000000000564","article-title":"Postoperative opioid-induced respiratory depression: a closed claims analysis.","volume":"122","author":"Lee","year":"2015","journal-title":"Anesthesiology"},{"key":"R3-20260617","first-page":"361","article-title":"Dangers of postoperative opioids\u2014APSF Workshop and white paper address prevention of postoperative respiratory complications.","volume":"21","author":"Weinger","year":"2006","journal-title":"Newsletter"},{"key":"R4-20260617","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/NNA.0000000000000301","article-title":"Avoiding adverse events secondary to opioid-induced respiratory depression: implications for nurse executives and Patient Safety.","volume":"46","author":"Jungquist","year":"2016","journal-title":"J Nurs Adm"},{"key":"R5-20260617","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1213\/ANE.0000000000004195","article-title":"Society for Obstetric Anesthesia and Perinatology Consensus Statement: monitoring recommendations for prevention and detection of respiratory depression associated with administration of neuraxial morphine for cesarean delivery analgesia.","volume":"129","author":"Bauchat","year":"2019","journal-title":"Anesth Analg"},{"key":"R6-20260617","first-page":"101309","article-title":"A randomized controlled trial of spinal morphine with an enhanced recovery pathway and its effect on duration of analgesia after cesarean delivery.","volume":"43","author":"Borrelli","year":"2024","journal-title":"Anaesth Crit Care Pain Med"},{"key":"R7-20260617","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.ijoa.2016.08.003","article-title":"Dose-response of intrathecal morphine when administered with intravenous ketorolac for post-cesarean analgesia: a two-center, prospective, randomized, blinded trial.","volume":"28","author":"Berger","year":"2016","journal-title":"Int J Obstet Anesth"},{"key":"R8-20260617","doi-asserted-by":"crossref","first-page":"e939567","DOI":"10.12659\/MSM.939567","article-title":"Efficacy and safety of low-dose versus high-dose postoperative intrathecal morphine in 62 women undergoing elective cesarean section delivery at full term.","volume":"29","author":"Fei","year":"2023","journal-title":"Med Sci Monit"},{"key":"R9-20260617","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1213\/00000539-199902000-00023","article-title":"Determination of an effective dose of intrathecal morphine for pain relief after cesarean delivery.","volume":"88","author":"Gerancher","year":"1999","journal-title":"Anesth Analg"},{"key":"R10-20260617","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1213\/ANE.0000000000001255","article-title":"The effect of intrathecal morphine dose on outcomes after elective cesarean delivery: a meta-analysis.","volume":"123","author":"Sultan","year":"2016","journal-title":"Anesth Analg"},{"key":"R11-20260617","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1136\/rapm-2018-100206","article-title":"Impact of patient choice for different postcesarean delivery analgesic protocols on opioid consumption: a randomized prospective clinical trial.","volume":"44","author":"Carvalho","year":"2019","journal-title":"Reg Anesth Pain Med"},{"key":"R12-20260617","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1213\/ANE.0000000000003636","article-title":"A systematic review evaluating neuraxial morphine and diamorphine-associated respiratory depression after cesarean delivery.","volume":"127","author":"Sharawi","year":"2018","journal-title":"Anesth Analg"},{"key":"R13-20260617","doi-asserted-by":"crossref","first-page":"103187","DOI":"10.1016\/j.ijoa.2021.103187","article-title":"Quantifying the incidence of clinically significant respiratory depression in women with and without obesity class III receiving neuraxial morphine for post-cesarean analgesia: a retrospective cohort study.","volume":"47","author":"Ende","year":"2021","journal-title":"Int J Obstet Anesth"},{"key":"R14-20260617","doi-asserted-by":"crossref","first-page":"762","DOI":"10.1093\/bja\/aex039","article-title":"Patient choice compared with no choice of intrathecal morphine dose for caesarean analgesia: a randomized clinical trial.","volume":"118","author":"Carvalho","year":"2017","journal-title":"Br J Anaesth"},{"key":"R15-20260617","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1213\/ANE.0b013e318290c798","article-title":"The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry.","volume":"117","author":"Ramsay","year":"2013","journal-title":"Anesth Analg"},{"key":"R16-20260617","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1213\/ANE.0000000000001160","article-title":"Advanced monitoring is associated with fewer alarm events during planned moderate procedure-related sedation: a 2-part pilot trial.","volume":"122","author":"Applegate","year":"2016","journal-title":"Anesth Analg"},{"key":"R17-20260617","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1007\/s10877-015-9822-4","article-title":"Acoustic method respiratory rate monitoring is useful in patients under intravenous anesthesia.","volume":"31","author":"Ouchi","year":"2017","journal-title":"J Clin Monit Comput"},{"key":"R18-20260617","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1213\/ANE.0000000000003503","article-title":"Prospective observational investigation of capnography and pulse oximetry monitoring after cesarean delivery with intrathecal morphine.","volume":"128","author":"Weiniger","year":"2019","journal-title":"Anesth Analg"},{"key":"R19-20260617","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1002\/sim.5947","article-title":"Sample size calculation for comparing two negative binomial rates.","volume":"33","author":"Zhu","year":"2014","journal-title":"Stat Med"},{"key":"R20-20260617","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1097\/00000542-198811000-00044","article-title":"Mini-dose intrathecal morphine for analgesia following cesarean section.","volume":"69","author":"Abboud","year":"1988","journal-title":"Anesthesiology"},{"key":"R21-20260617","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.jclinane.2007.07.010","article-title":"Intrathecal morphine in anesthesia for cesarean delivery: dose-response relationship for combinations of low-dose intrathecal morphine and spinal bupivacaine.","volume":"20","author":"Girgin","year":"2008","journal-title":"J Clin Anesth"},{"key":"R22-20260617","doi-asserted-by":"crossref","first-page":"103592","DOI":"10.1016\/j.ijoa.2022.103592","article-title":"Respiratory depression after administration of single-dose neuraxial morphine for post-cesarean delivery analgesia: a retrospective cohort study.","volume":"52","author":"Palleschi","year":"2022","journal-title":"Int J Obstet Anesth"},{"key":"R23-20260617","doi-asserted-by":"crossref","first-page":"37","DOI":"10.56026\/imu.15.3.37","article-title":"24-hour observation of patients after intrathecal morphine for lower segment caesarean section\u2014Is it overrated? A prospective observational study.","volume":"15","author":"Subramaniam","year":"2021","journal-title":"Inter e-J Sci Med Educ"},{"key":"R24-20260617","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1097\/ALN.0000000000000975","article-title":"An updated report by the American Society of Anesthesiologists Task Force on Neuraxial Opioids and the American Society of Regional Anesthesia and Pain Medicine.","volume":"124","year":"2016","journal-title":"Anesthesiology"},{"key":"R25-20260617","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1007\/s00540-023-03163-x","article-title":"Respiratory depression following cesarean section with single-shot spinal with 100 mug morphine.","volume":"37","author":"Onodera","year":"2023","journal-title":"J Anesth"},{"key":"R26-20260617","doi-asserted-by":"crossref","first-page":"100295","DOI":"10.1016\/j.resplu.2022.100295","article-title":"Understanding the \u201calarm problem\u201d associated with continuous physiologic monitoring of general care patients.","volume":"11","author":"McGrath","year":"2022","journal-title":"Resusc Plus"},{"key":"R27-20260617","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1111\/j.1365-2044.2008.05817.x","article-title":"Risks and side-effects of intrathecal morphine combined with spinal anaesthesia: a meta-analysis.","volume":"64","author":"Gehling","year":"2009","journal-title":"Anaesthesia"},{"key":"R28-20260617","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1213\/ANE.0b013e3182a9b042","article-title":"A retrospective assessment of the incidence of respiratory depression after neuraxial morphine administration for postcesarean delivery analgesia.","volume":"117","author":"Crowgey","year":"2013","journal-title":"Anesth Analg"},{"key":"R29-20260617","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1136\/bmjqs-2017-006671","article-title":"Is everyone really breathing 20 times a minute? Assessing epidemiology and variation in recorded respiratory rate in hospitalised adults.","volume":"26","author":"Badawy","year":"2017","journal-title":"BMJ Qual Saf"},{"key":"R30-20260617","doi-asserted-by":"crossref","first-page":"1807","DOI":"10.2165\/11596250-000000000-00000","article-title":"Neuraxial morphine and respiratory depression: finding the right balance.","volume":"71","author":"Sultan","year":"2011","journal-title":"Drugs"},{"key":"R31-20260617","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1213\/ANE.0000000000005098","article-title":"Postoperative opioid-induced respiratory depression: 3 steps forward.","volume":"131","author":"Prielipp","year":"2020","journal-title":"Anesth Analg"},{"key":"R32-20260617","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1097\/ALN.0000000000001895","article-title":"Incidence of artifacts and deviating values in research data obtained from an anesthesia information management system in children.","volume":"128","author":"Hoorweg","year":"2018","journal-title":"Anesthesiology"},{"key":"R33-20260617","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1007\/s12630-012-9754-0","article-title":"Artifacts in research data obtained from an anesthesia information and management system.","volume":"59","author":"Kool","year":"2012","journal-title":"Can J Anaesth"},{"key":"R34-20260617","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1007\/s10877-020-00574-z","article-title":"Artifacts annotations in anesthesia blood pressure data by man and machine.","volume":"35","author":"Pasma","year":"2021","journal-title":"J Clin Monit Comput"},{"key":"R35-20260617","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1097\/ALN.0000000000004971","article-title":"A comparison of five algorithmic methods and machine learning pattern recognition for artifact detection in electronic records of five different vital signs: a retrospective analysis.","volume":"141","author":"Maleczek","year":"2024","journal-title":"Anesthesiology"},{"key":"R36-20260617","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1097\/00000542-199307000-00010","article-title":"Dose-response pharmacology of intrathecal morphine in human volunteers.","volume":"79","author":"Bailey Peter","year":"1993","journal-title":"Anesthesiology"},{"key":"R37-20260617","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1136\/rapm-00115550-199116030-00005","article-title":"The addition of 0.2 mg subarachnoid morphine to hyperbaric bupivacaine for cesarean delivery: a prospective study of 856 cases.","volume":"16","author":"Abouleish","year":"1991","journal-title":"Reg Anesth"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000007908","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:25:44Z","timestamp":1786112744000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000007908"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,5]]},"references-count":37,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000007908","relation":{},"ISSN":["0003-2999","1526-7598"],"issn-type":[{"value":"0003-2999","type":"print"},{"value":"1526-7598","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,5]]}}}