{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T23:04:55Z","timestamp":1789513495633,"version":"build-2803163510"},"reference-count":45,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Oscillatory high-frequency ventilation modalities, including high-frequency oscillatory, percussive, and jet ventilation, are commonly used during anesthesia and critical care to improve oxygenation or facilitate airway surgery. These techniques rely on rapid, small-amplitude pressure oscillations to sustain gas exchange while minimizing baro- or volutrauma. However, how effectively such oscillations transmit through the conducting airways to the alveoli in mechanically heterogeneous lungs remains poorly understood, particularly under perioperative conditions associated with atelectasis, airway narrowing, or altered chest wall mechanics.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>\n                      We combined in vivo measurements in anesthetized, mechanically ventilated piglets with computational simulations to quantify pressure transmission and ventilation heterogeneity across controlled variations in airway and tissue mechanical properties. Airway opening, tracheal, and alveolar capsule pressures (n = 16) were recorded with miniature pressure transducers during multifrequency (0.5\u201320.75 Hz) oscillations at positive end-expiratory pressures (PEEP) of 5 and 10 cmH\n                      <jats:sub>2<\/jats:sub>\n                      O. The experimental data informed a simulation model comprising heterogeneous airway and tissue compartments to identify determinants of alveolar ventilation during oscillatory modes.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      The\n                      <jats:italic toggle=\"yes\">in vivo<\/jats:italic>\n                      measurements revealed that the endotracheal tube accounted for most of the total flow resistance and inertance, whereas the chest wall contributed approximately two-thirds of tissue damping and elastance. Only 29% (95% confidence interval [CI], 22%\u201336%) to 43% (95% CI, 32%\u201354%) of tracheal oscillatory pressure reached the alveoli, showing strong frequency-dependent attenuation that was not significantly influenced by PEEP. Simulation results validated against measured pressure transfer functions indicated that airway heterogeneity dominated regional disparities in pressure and tidal volume, causing up to 250% differences in local volumes at high net resistance. Tissue heterogeneity exerted smaller (&lt;100%) but distinct effects on pressure\u2013volume relationships.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Airway heterogeneity, common in perioperative atelectasis, bronchospasm, and acute lung injury, profoundly limits the efficiency of oscillatory ventilation. Understanding how airway and tissue properties modulate oscillatory pressure transmission provides a mechanistic basis for tailoring high-frequency ventilation to individual patients. These insights may inform more rational ventilation strategies to optimize gas exchange while minimizing regional overdistension and collapse.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000008029","type":"journal-article","created":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T17:00:10Z","timestamp":1774371610000},"page":"907-916","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Efficiency of Alveolar Ventilation During High-Frequency Modes in Piglets: Effects of Airway and Tissue Heterogeneity"],"prefix":"10.1213","volume":"143","author":[{"given":"P\u00e9ter","family":"Makra","sequence":"first","affiliation":[{"name":"Department of Medical Physics and Informatics, University of Szeged, Szeged, Hungary"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gergely H.","family":"Fodor","sequence":"additional","affiliation":[{"name":"Department of Medical Physics and Informatics, University of Szeged, Szeged, Hungary"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberta","family":"S\u00fcdy","sequence":"additional","affiliation":[{"name":"Unit for Anesthesiological Investigations, Department of Anesthesiology, Clinical Pharmacology, Intensive Care and Emergency Medicine, University of Geneva, Geneva, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00c1lmos","family":"Schranc","sequence":"additional","affiliation":[{"name":"Unit for Anesthesiological Investigations, Department of Anesthesiology, Clinical Pharmacology, Intensive Care and Emergency Medicine, University of Geneva, Geneva, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gergely","family":"Albu","sequence":"additional","affiliation":[{"name":"Unit for Anesthesiological Investigations, Department of Anesthesiology, Clinical Pharmacology, Intensive Care and Emergency Medicine, University of Geneva, Geneva, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Walid","family":"Habre","sequence":"additional","affiliation":[{"name":"Unit for Anesthesiological Investigations, Department of Anesthesiology, Clinical Pharmacology, Intensive Care and Emergency Medicine, University of Geneva, Geneva, Switzerland"},{"name":"Department of Anesthesiology, Critical Care and Pain Medicine, Boston Children\u2019s Hospital, Boston, Massachusetts."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ferenc","family":"Pet\u00e1k","sequence":"additional","affiliation":[{"name":"Department of Medical Physics and Informatics, University of Szeged, Szeged, Hungary"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,3,23]]},"reference":[{"key":"R1-20260915","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.cophys.2021.03.006","article-title":"Oscillatory ventilation redux: alternative perspectives on ventilator-induced lung injury in the acute respiratory distress syndrome.","volume":"21","author":"Kaczka","year":"2021","journal-title":"Curr Opin Physiol"},{"key":"R2-20260915","doi-asserted-by":"crossref","first-page":"1810","DOI":"10.1038\/s41390-021-01639-8","article-title":"High-frequency ventilation in preterm infants and neonates.","volume":"93","author":"Ackermann","year":"2023","journal-title":"Pediatr Res"},{"key":"R3-20260915","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1186\/s12931-024-03049-w","article-title":"Gas transport mechanisms during high-frequency ventilation.","volume":"25","author":"Scott","year":"2024","journal-title":"Respir Res"},{"key":"R4-20260915","doi-asserted-by":"crossref","first-page":"845","DOI":"10.4187\/respcare.08691","article-title":"High-frequency jet ventilation in neonatal and pediatric subjects: a narrative review.","volume":"66","author":"Miller","year":"2021","journal-title":"Respir Care"},{"key":"R5-20260915","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.4187\/respcare.01571","article-title":"Reflections on pediatric high-frequency oscillatory ventilation from a physiologic perspective.","volume":"57","author":"Kneyber","year":"2012","journal-title":"Respir Care"},{"issue":"7 suppl 1","key":"R6-20260915","doi-asserted-by":"crossref","first-page":"102S","DOI":"10.1093\/bja\/63.7.102","article-title":"Clinical uses of high frequency jet ventilation in anaesthesia.","volume":"63","author":"Giunta","year":"1989","journal-title":"Br J Anaesth"},{"key":"R7-20260915","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1186\/s12931-022-02215-2","article-title":"Expiratory high-frequency percussive ventilation: a novel concept for improving gas exchange.","volume":"23","author":"Petak","year":"2022","journal-title":"Respir Res"},{"key":"R8-20260915","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/0034-5687(83)90111-1","article-title":"Mechanical ventilation with superimposed high frequency oscillation in the normal rat.","volume":"54","author":"Harf","year":"1983","journal-title":"Respir Physiol"},{"key":"R9-20260915","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1002\/ppul.25191","article-title":"High frequency percussive ventilation in pediatric acute respiratory failure.","volume":"56","author":"Butler","year":"2021","journal-title":"Pediatr Pulmonol"},{"key":"R10-20260915","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s13054-017-1924-6","article-title":"High frequency percussive ventilation increases alveolar recruitment in early acute respiratory distress syndrome: an experimental, physiological and CT scan study.","volume":"22","author":"Godet","year":"2018","journal-title":"Crit Care"},{"key":"R11-20260915","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1038\/s41372-024-02185-x","article-title":"Elective high frequency oscillatory ventilation versus conventional mechanical ventilation on the chronic lung disease or death in preterm infants administered surfactant: a systematic review and meta-analysis.","volume":"45","author":"Yu","year":"2025","journal-title":"J Perinatol"},{"key":"R12-20260915","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1038\/s41390-025-04015-y","article-title":"Are we ready for volume targeting during high-frequency oscillatory ventilation in neonates?","volume":"98","author":"Tingay","year":"2025","journal-title":"Pediatr Res"},{"key":"R13-20260915","doi-asserted-by":"crossref","first-page":"813478","DOI":"10.3389\/fphys.2022.813478","article-title":"The physiological basis of high-frequency oscillatory ventilation and current evidence in adults and children: a narrative review.","volume":"13","author":"Miller","year":"2022","journal-title":"Front Physiol"},{"key":"R14-20260915","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1136\/archdischild-2023-325657","article-title":"Neonatal high-frequency oscillatory ventilation: where are we now?","volume":"109","author":"Hibberd","year":"2024","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"R15-20260915","doi-asserted-by":"crossref","first-page":"2240","DOI":"10.1038\/s41390-025-04173-z","article-title":"Preterm infants on high-frequency oscillatory ventilation: electrical impedance tomography during lung recruitment.","volume":"98","author":"Werther","year":"2025","journal-title":"Pediatr Res"},{"key":"R16-20260915","doi-asserted-by":"crossref","first-page":"e66","DOI":"10.1097\/CCM.0000000000004073","article-title":"High-frequency oscillatory ventilation and ventilator-induced lung injury: size does matter.","volume":"48","author":"Herrmann","year":"2020","journal-title":"Crit Care Med"},{"key":"R17-20260915","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1152\/jappl.1992.72.1.168","article-title":"Input impedance and peripheral inhomogeneity of dog lungs.","volume":"72","author":"Hantos","year":"1992","journal-title":"J Appl Physiol (1985)"},{"key":"R18-20260915","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1152\/japplphysiol.00048.2019","article-title":"Different contributions from lungs and chest wall to respiratory mechanics in mice, rats, and rabbits.","volume":"127","author":"Sudy","year":"2019","journal-title":"J Appl Physiol (1985)"},{"key":"R19-20260915","doi-asserted-by":"crossref","first-page":"1841","DOI":"10.1152\/jappl.1996.80.5.1841","article-title":"Airway inhomogeneities contribute to apparent lung tissue mechanics during constriction.","volume":"80","author":"Lutchen","year":"1996","journal-title":"J Appl Physiol (1985)"},{"key":"R20-20260915","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1152\/jappl.1997.82.4.1349","article-title":"Partitioning of lung tissue response and inhomogeneous airway constriction at the airway opening.","volume":"82","author":"Suki","year":"1997","journal-title":"J Appl Physiol (1985)"},{"key":"R21-20260915","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1097\/00000542-200508000-00014","article-title":"Quantifying mechanical heterogeneity in canine acute lung injury: impact of mean airway pressure.","volume":"103","author":"Kaczka","year":"2005","journal-title":"Anesthesiology"},{"key":"R22-20260915","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1056\/NEJMoa1215716","article-title":"High-frequency oscillation for acute respiratory distress syndrome.","volume":"368","author":"Young","year":"2013","journal-title":"N Engl J Med"},{"key":"R23-20260915","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1056\/NEJMoa1215554","article-title":"High-frequency oscillation in early acute respiratory distress syndrome.","volume":"368","author":"Ferguson","year":"2013","journal-title":"N Engl J Med"},{"key":"R24-20260915","doi-asserted-by":"crossref","first-page":"1530","DOI":"10.1097\/00003246-199422100-00006","article-title":"Prospective, randomized comparison of high-frequency oscillatory ventilation and conventional mechanical ventilation in pediatric respiratory failure.","volume":"22","author":"Arnold","year":"1994","journal-title":"Crit Care Med"},{"key":"R25-20260915","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1001\/jamapediatrics.2013.4463","article-title":"Comparison of high-frequency oscillatory ventilation and conventional mechanical ventilation in pediatric respiratory failure.","volume":"168","author":"Gupta","year":"2014","journal-title":"JAMA Pediatr"},{"key":"R26-20260915","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1088\/0967-3334\/32\/9\/007","article-title":"Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants-the impact of ventilator settings on tracheal pressure swings.","volume":"32","author":"Hentschel","year":"2011","journal-title":"Physiol Meas"},{"key":"R27-20260915","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1152\/japplphysiol.01120.2011","article-title":"Respiratory mechanics during high-frequency oscillatory ventilation: a physical model and preterm infant study.","volume":"112","author":"Singh","year":"2012","journal-title":"J Appl Physiol (1985)"},{"key":"R28-20260915","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.1152\/jappl.1992.73.3.1040","article-title":"Lung and chest wall impedances in the dog in normal range of breathing: effects of pulmonary edema.","volume":"73","author":"Barnas","year":"1992","journal-title":"J Appl Physiol (1985)"},{"key":"R29-20260915","doi-asserted-by":"crossref","first-page":"130","DOI":"10.3109\/01902148.2013.772680","article-title":"Deviation of tracheal pressure from airway opening pressure during high-frequency oscillatory ventilation in a porcine lung model.","volume":"39","author":"Johannes","year":"2013","journal-title":"Exp Lung Res"},{"key":"R30-20260915","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1203\/00006450-200210000-00013","article-title":"Dependence of intrapulmonary pressure amplitudes on respiratory mechanics during high-frequency oscillatory ventilation in preterm lambs.","volume":"52","author":"Pillow","year":"2002","journal-title":"Pediatr Res"},{"key":"R31-20260915","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.resp.2008.05.005","article-title":"Pressure loss caused by pediatric endotracheal tubes during high-frequency-oscillation-ventilation.","volume":"162","author":"Schumann","year":"2008","journal-title":"Respir Physiol Neurobiol"},{"key":"R32-20260915","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1111\/j.1365-2044.1991.tb09658.x","article-title":"Tracheal tube resistance and airway and alveolar pressures during mechanical ventilation in the neonate.","volume":"46","author":"Tipping","year":"1991","journal-title":"Anaesthesia"},{"issue":"3 suppl","key":"R33-20260915","doi-asserted-by":"crossref","first-page":"S142","DOI":"10.1097\/01.CCM.0000155924.74942.7F","article-title":"High-frequency oscillatory ventilation: lessons learned from mechanical test lung models.","volume":"33","author":"Van de Kieft","year":"2005","journal-title":"Crit Care Med"},{"key":"R34-20260915","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1002\/ppul.1075","article-title":"Reduction of oscillatory pressure along the endotracheal tube is indicative for maximal respiratory compliance during high-frequency oscillatory ventilation: a mathematical model study.","volume":"31","author":"van Genderingen","year":"2001","journal-title":"Pediatr Pulmonol"},{"issue":"9 suppl","key":"R35-20260915","doi-asserted-by":"crossref","first-page":"S49","DOI":"10.1097\/00003246-199422091-00004","article-title":"Understanding the pressure cost of ventilation: why does high-frequency ventilation work?","volume":"22","author":"Venegas","year":"1994","journal-title":"Crit Care Med"},{"key":"R36-20260915","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1203\/00006450-198502000-00002","article-title":"Alveolar pressure swings during high frequency ventilation in rabbits.","volume":"19","author":"Frantz","year":"1985","journal-title":"Pediatr Res"},{"key":"R37-20260915","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1203\/00006450-199010000-00013","article-title":"Proximal, tracheal, and alveolar pressures during high-frequency oscillatory ventilation in a normal rabbit model.","volume":"28","author":"Gerstmann","year":"1990","journal-title":"Pediatr Res"},{"key":"R38-20260915","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1203\/00006450-199001000-00018","article-title":"Frequency, tidal volume, and mean airway pressure combinations that provide adequate gas exchange and low alveolar pressure during high frequency oscillatory ventilation in rabbits.","volume":"27","author":"Kamitsuka","year":"1990","journal-title":"Pediatr Res"},{"key":"R39-20260915","doi-asserted-by":"crossref","first-page":"1113100","DOI":"10.3389\/fphys.2023.1113100","article-title":"Airway remodeling heterogeneity in asthma and its relationship to disease outcomes.","volume":"14","author":"Hsieh","year":"2023","journal-title":"Front Physiol"},{"key":"R40-20260915","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1513\/AnnalsATS.202404-446OC","article-title":"Airway remodeling in cystic fibrosis is heterogeneous.","volume":"22","author":"Vermaut","year":"2025","journal-title":"Ann Am Thorac Soc"},{"key":"R41-20260915","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1152\/japplphysiol.01031.2017","article-title":"Oscillometry and pulmonary MRI measurements of ventilation heterogeneity in obstructive lung disease: relationship to quality of life and disease control.","volume":"125","author":"Young","year":"2018","journal-title":"J Appl Physiol (1985)"},{"key":"R42-20260915","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1152\/jappl.1956.8.4.427","article-title":"Mechanical factors in distribution of pulmonary ventilation.","volume":"8","author":"Otis","year":"1956","journal-title":"J Appl Physiol"},{"key":"R43-20260915","doi-asserted-by":"crossref","first-page":"1332958","DOI":"10.3389\/fmedt.2024.1332958","article-title":"Editorial: understanding the impact of lung ventilation heterogeneity.","volume":"6","author":"Kuhn","year":"2024","journal-title":"Front Med Technol"},{"key":"R44-20260915","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1165\/rcmb.2013-0453TR","article-title":"Anatomy and bronchoscopy of the porcine lung. A model for translational respiratory medicine.","volume":"51","author":"Judge","year":"2014","journal-title":"Am J Respir Cell Mol Biol"},{"key":"R45-20260915","doi-asserted-by":"crossref","first-page":"1461","DOI":"10.1007\/s10877-021-00788-9","article-title":"A comparison of endotracheal tube compensation techniques for the measurement of respiratory mechanical impedance at low frequencies.","volume":"36","author":"Cruz","year":"2022","journal-title":"J Clin Monit Comput"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000008029","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T23:00:24Z","timestamp":1789513224000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000008029"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,23]]},"references-count":45,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000008029","relation":{},"ISSN":["0003-2999","1526-7598"],"issn-type":[{"value":"0003-2999","type":"print"},{"value":"1526-7598","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,23]]}}}