{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T10:42:01Z","timestamp":1792060921786,"version":"4.4.0"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2009,9]]},"DOI":"10.1213\/ane.0b013e3181ae39db","type":"journal-article","created":{"date-parts":[[2009,8,15]],"date-time":"2009-08-15T03:14:22Z","timestamp":1250306062000},"page":"825-831","source":"Crossref","is-referenced-by-count":92,"title":["A Macintosh Laryngoscope Blade for Videolaryngoscopy Reduces Stylet Use in Patients with Normal Airways"],"prefix":"10.1213","volume":"109","author":[{"given":"Andr\u00e9","family":"van Zundert","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ralph","family":"Maassen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruben","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Remi","family":"Willems","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michel","family":"Timmerman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Siemonsma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Buise","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Wiepking","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-22-20210902","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1007\/BF03018651","article-title":"Use of a new videolaryngoscope (GlideScope) in the management of a difficult airway.","volume":"50","author":"Cooper","year":"2003","journal-title":"Can J Anaesth"},{"key":"R2-22-20210902","first-page":"129","article-title":"Video-assisted laryngoscopy: a useful adjunct in endotracheal intubation.","volume":"58","author":"Van Zundert","year":"2007","journal-title":"Acta Anaesthesiol Belg"},{"key":"R3-22-20210902","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1007\/BF03021900","article-title":"Complications associated with the use of the GlideScope videolaryngoscope.","volume":"54","author":"Cooper","year":"2007","journal-title":"Can J Anaesth"},{"issue":"suppl 2","key":"R4-22-20210902","doi-asserted-by":"crossref","first-page":"S479","DOI":"10.1007\/s00464-006-0038-z","article-title":"Seeing is believing: the importance of video laryngoscopy in teaching and in managing the difficult airway.","volume":"20","author":"Kaplan","year":"2006","journal-title":"Surg Endosc"},{"key":"R5-22-20210902","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/BF03027728","article-title":"Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients.","volume":"52","author":"Cooper","year":"2005","journal-title":"Can J Anaesth"},{"key":"R6-22-20210902","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1007\/BF03021635","article-title":"More maneuvers to facilitate tracheal intubation with the GlideScope.","volume":"53","author":"Kramer","year":"2006","journal-title":"Can J Anaesth"},{"key":"R7-22-20210902","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1007\/BF03021905","article-title":"Tracheal intubation using the GlideScope with a combined curved pipe stylet, and endotracheal tube introducer.","volume":"54","author":"Muallem","year":"2007","journal-title":"Can J Anaesth"},{"key":"R9-22-20210902","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1007\/BF03022777","article-title":"Case series: the McGrath videolaryngoscope\u2014an initial clinical evaluation.","volume":"54","author":"Shippey","year":"2007","journal-title":"Can J Anaesth"},{"key":"R10-22-20210902","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1093\/bja\/aem303","article-title":"Use of the McGrath videolaryngoscope in the management of difficult and failed tracheal intubation.","volume":"100","author":"Shippey","year":"2008","journal-title":"Br J Anaesth"},{"key":"R11-22-20210902","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1016\/j.jclinane.2007.03.010","article-title":"Soft palate perforation during orotracheal intubation facilitated by the GlideScope videolaryngoscope.","volume":"19","author":"Vincent","year":"2007","journal-title":"J Clin Anesth"},{"key":"R12-22-20210902","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1007\/BF03022782","article-title":"Another complication associated with videolaryngoscopy.","volume":"54","author":"Choo","year":"2007","journal-title":"Can J Anaesth"},{"key":"R13-22-20210902","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.otohns.2007.02.038","article-title":"Pharyngeal injury related to GlideScope videolaryngoscope.","volume":"137","author":"Hirabayashi","year":"2007","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R14-22-20210902","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1213\/01.ane.0000265490.26332.48","article-title":"Penetrating injury of the soft palate during GlideScope intubation.","volume":"104","author":"Hsu","year":"2007","journal-title":"Anesth Analg"},{"key":"R15-22-20210902","doi-asserted-by":"crossref","first-page":"1610","DOI":"10.1213\/01.ane.0000264321.04403.06","article-title":"Anterior tonsillar pillar perforation during GlideScope video laryngoscopy.","volume":"104","author":"Malik","year":"2007","journal-title":"Anesth Analg"},{"key":"R16-22-20210902","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/S1875-4597(08)60019-3","article-title":"Penetrating injury of the palatoglossal arch associated with use of the GlideScope videolaryngoscope in a flame burn patient.","volume":"46","author":"Hsu","year":"2008","journal-title":"Acta Anaesthesiol Taiwan"},{"key":"R17-22-20210902","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1007\/BF03021895","article-title":"Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope.","volume":"54","author":"Jones","year":"2007","journal-title":"Can J Anaesth"},{"key":"R18-22-20210902","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1007\/BF03026792","article-title":"The GlideScope-specific rigid stylet and standard malleable stylet are equally effective for GlideScope use.","volume":"54","author":"Turkstra","year":"2007","journal-title":"Can J Anaesth"},{"key":"R19-22-20210902","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.jclinane.2006.01.002","article-title":"Comparison of direct and video-assisted views of the larynx during routine intubation.","volume":"18","author":"Kaplan","year":"2006","journal-title":"J Clin Anesth"},{"key":"R20-22-20210902","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1016\/j.jclinane.2006.03.018","article-title":"A clinical assessment of the Glidescope videolaryngoscope in nasotracheal intubation with general anesthesia.","volume":"18","author":"Xue","year":"2006","journal-title":"J Clin Anesth"},{"key":"R21-22-20210902","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1093\/bja\/aei041","article-title":"The GlideScope video laryngoscope: randomized clinical trial in 200 patients.","volume":"94","author":"Sun","year":"2005","journal-title":"Br J Anaesth"},{"key":"R22-22-20210902","first-page":"451","article-title":"The clinical assessment of Glidescope in orotracheal intubation under general anesthesia.","volume":"73","author":"Xue","year":"2007","journal-title":"Minerva Anestesiol"},{"key":"R23-22-20210902","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1017\/S0265021506002067","article-title":"Comparison of the GlideScope video laryngoscope vs. the intubating laryngeal mask for females with normal airways.","volume":"24","author":"Fun","year":"2007","journal-title":"Eur J Anaesthesiol"},{"key":"R24-22-20210902","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1093\/bja\/ael133","article-title":"The use of the GlideScope for tracheal intubation in patients with ankylosing spondylitis.","volume":"97","author":"Lai","year":"2006","journal-title":"Br J Anaesth"},{"key":"R25-22-20210902","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1007\/BF03021589","article-title":"The StyletScope(R) facilitates tracheal intubation with the GlideScope\u00ae.","volume":"53","author":"Hirabayashi","year":"2006","journal-title":"Can J Anaesth"},{"key":"R26-22-20210902","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1007\/BF03022966","article-title":"The GlideScope cobalt videolaryngoscope\u2014a novel single-use device.","volume":"54","author":"Jones","year":"2007","journal-title":"Can J Anaesth"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/ane.0b013e3181ae39db","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:12:41Z","timestamp":1786111961000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00000539-200909000-00022"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,9]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2009]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0b013e3181ae39db","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2009,9]]}}}