{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T06:51:31Z","timestamp":1794293491727,"version":"4.9.0"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>An endotracheal tube (ETT) cuff leakage has serious consequences. Anatomical abnormalities are rare but are possible causes. We report the case of a patient having a robot-assisted laparoscopic prostatectomy. Endotracheal intubation was performed successfully. However, a cuff leak occurred, and persisted despite standard management efforts. The ETT was carefully advanced until one-lung ventilation was established and then gradually withdrawn until bilateral lung ventilation was restored. Chest computed tomography revealed a tracheal diverticulum immediately below the vocal cords as the underlying cause. If standard troubleshooting fails to resolve a cuff leak, unusual causes should be considered.<\/jats:p>","DOI":"10.1213\/xaa.0000000000002011","type":"journal-article","created":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T08:00:50Z","timestamp":1751356850000},"page":"e02011","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["A Persistent Endotracheal Tube Cuff Leak Due to an Undiagnosed Tracheal Diverticulum: A Case Report"],"prefix":"10.1213","volume":"19","author":[{"given":"Ikumi","family":"Sawada","sequence":"first","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Jichi Medical University Saitama Medical Center, Saitama, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusuke","family":"Iizuka","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Jichi Medical University Saitama Medical Center, Saitama, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akihiro","family":"Kajisako","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Jichi Medical University Saitama Medical Center, Saitama, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuji","family":"Otsuka","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Jichi Medical University Saitama Medical Center, Saitama, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masamitsu","family":"Sanui","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Jichi Medical University, Saitama, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,7,1]]},"reference":[{"key":"R1-20250701","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/0002-9343(81)90413-7","article-title":"Complications and consequences of endotracheal intubation and tracheotomy: A prospective study of 150 critically ill adult patients.","volume":"70","author":"Stauffer","year":"1981","journal-title":"Am J Med"},{"key":"R2-20250701","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1213\/ANE.0b013e318292ee21","article-title":"Endotracheal tube cuff leaks: Causes, consequences, and management.","volume":"117","author":"El-Orbany","year":"2013","journal-title":"Anesth Analg"},{"key":"R3-20250701","doi-asserted-by":"crossref","first-page":"145","DOI":"10.5152\/eajm.2013.31","article-title":"A multi detector computed tomography survey of tracheal diverticulum.","volume":"45","author":"Kurt","year":"2013","journal-title":"Eurasian J Med"},{"key":"R4-20250701","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1186\/s12871-023-02347-y","article-title":"Positional relationships between a tracheal diverticulum and the tracheal tube under general anesthesia: A single-center observational and simulation study.","volume":"23","author":"Mitsuzawa","year":"2023","journal-title":"BMC Anesthesiol"},{"key":"R5-20250701","first-page":"E11","article-title":"Tracheal diverticulum: A report of 4 cases.","volume":"88","author":"Sharma","year":"2009","journal-title":"Ear Nose Throat J"},{"key":"R6-20250701","doi-asserted-by":"crossref","first-page":"1376","DOI":"10.1183\/09031936.94.07071376","article-title":"Tracheocele: A rare cause of difficult endotracheal intubation and subsequent pneumomediastinum.","volume":"7","author":"M\u00f6ller","year":"1994","journal-title":"Eur Respir J"},{"key":"R7-20250701","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1046\/j.1365-2044.2000.01664-18.x","article-title":"Difficult tracheal intubation secondary to a tracheal diverticulum and a 90\u2009degree deviation in the trachea.","volume":"55","author":"Davies","year":"2000","journal-title":"Anaesthesia"},{"key":"R8-20250701","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1097\/00000542-199209000-00026","article-title":"Ventilation difficulty secondary to a tracheal diverticulum.","volume":"77","author":"Dinner","year":"1992","journal-title":"Anesthesiology"},{"key":"R9-20250701","doi-asserted-by":"crossref","first-page":"e254134","DOI":"10.1136\/bcr-2022-254134","article-title":"Ventilation failure with elective tracheostomy during oral cancer surgery: A case of tracheal diverticulum.","volume":"16","author":"Mitra","year":"2023","journal-title":"BMJ Case Rep"},{"key":"R10-20250701","doi-asserted-by":"crossref","first-page":"e34536","DOI":"10.1097\/MD.0000000000034536","article-title":"Rare and unexpected ventilation difficulties due to tracheal diverticulum: A case report.","volume":"102","author":"Zhou","year":"2023","journal-title":"Medicine (Baltim)"},{"key":"R11-20250701","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1111\/anae.12193","article-title":"Pneumomediastinum related to distal tracheal diverticulum.","volume":"68","author":"Mazul-Sunko","year":"2013","journal-title":"Anaesthesia"},{"key":"R12-20250701","doi-asserted-by":"crossref","first-page":"bcr2016217518","DOI":"10.1136\/bcr-2016-217518","article-title":"Barotrauma induced tracheal diverticulum rupture: imaging findings.","volume":"2016","author":"O\u2019Leary","year":"2016","journal-title":"BMJ Case Rep"},{"key":"R13-20250701","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1007\/s12630-016-0646-6","article-title":"Tracheal diverticulum as a cause of subcutaneous emphysema following positive-pressure ventilation.","volume":"63","author":"Allaert","year":"2016","journal-title":"Can J Anaesth"},{"key":"R14-20250701","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1007\/s00134-018-5316-4","article-title":"The accidental discovery of a tracheal diverticulum.","volume":"45","author":"Varutti","year":"2019","journal-title":"Intensive Care Med"},{"key":"R15-20250701","doi-asserted-by":"crossref","first-page":"e943639","DOI":"10.12659\/AJCR.943639","article-title":"Life-threatening tracheal diverticulum rupture following laparoscopic cholecystectomy: A rare case report.","volume":"25","author":"Ose","year":"2024","journal-title":"Am J Case Rep"},{"key":"R16-20250701","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1111\/j.1399-6576.2011.02542.x","article-title":"Comparison of air-sealing characteristics of tapered- vs. cylindrical-shaped high-volume, low-pressure tube cuffs.","volume":"56","author":"Madjdpour","year":"2012","journal-title":"Acta Anaesthesiol Scand"}],"container-title":["A&amp;A Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/XAA.0000000000002011","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:28:48Z","timestamp":1786112928000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1213\/XAA.0000000000002011"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,1]]},"references-count":16,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1213\/xaa.0000000000002011","relation":{},"ISSN":["2575-3126"],"issn-type":[{"value":"2575-3126","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,1]]}}}