{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,13]],"date-time":"2023-09-13T17:29:12Z","timestamp":1694626152516},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"suppl_1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2006,7,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>OBJECTIVE:<\/jats:title>\n                  <jats:p>Parent vessel sacrifice is a useful treatment strategy for fusiform intracranial aneurysms. Originally performed using the detachable silicone balloon, endovascular arterial occlusion is currently achieved using coils, a process which can be limited by coil mass migration.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>METHODS:<\/jats:title>\n                  <jats:p>We demonstrate the use of the Amplatzer vascular plug as a fixed anchor within the target parent vessel to facilitate coil-mediated occlusion, especially in vascular segments not encased by a bony canal. The technique was used successfully in two patients: a 90-year-old woman presenting with IIIrd and VIth cranial nerve palsy from a fusiform left cavernous internal carotid aneurysm and a 44-year-old man with distal thromboemboli from a fusiform dissecting-type right vertebral artery involving the origin of the posterior inferior cerebellar artery.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>RESULTS:<\/jats:title>\n                  <jats:p>Both patients were treated successfully with proximal parent vessel occlusion using coils after deployment of an Amplatzer vascular plug proximal to the target lesion. With the Amplatzer device acting as a fixed anchor in the parent vessel, coils were deployed proximally in a compact configuration. After deployment of the vascular plugs and coils, hermetic occlusion of the parent vessel was documented angiographically.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>CONCLUSION:<\/jats:title>\n                  <jats:p>The Amplatzer vascular plug can facilitate coil occlusion of large cervical vessels by acting as a focal coil and embolic material immobilizer, which can prevent coil mass migration and lead to improved packing density.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1227\/01.neu.0000219856.66842.ef","type":"journal-article","created":{"date-parts":[[2006,7,13]],"date-time":"2006-07-13T08:24:31Z","timestamp":1152779071000},"page":"E171-E172","source":"Crossref","is-referenced-by-count":8,"title":["Use of the Amplatzer Vascular Plug as an Anchoring Scaffold for Coil-mediated Parent Vessel Occlusion: Technical Case Report"],"prefix":"10.1227","volume":"59","author":[{"given":"Daniel A.","family":"Hoit","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Cerebrovascular and Endovascular Division, Tufts-New England Medical Center, Boston, Massachusetts"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Clemens M.","family":"Schirmer","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cerebrovascular and Endovascular Division, Tufts-New England Medical Center, Boston, Massachusetts"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adel M.","family":"Malek","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cerebrovascular and Endovascular Division, Tufts-New England Medical Center, Boston, Massachusetts"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"2020010206195634400_R1-29","first-page":"910","article-title":"Prevention of complications resulting from endovascular carotid sacrifice: A retrospective assessment","volume":"46","author":"Abruzzo","year":"2000","journal-title":"Neurosurgery"},{"key":"2020010206195634400_R2-29","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1227\/01.NEU.0000073417.01297.93","article-title":"Treatment of hemorrhagic intracranial dissections","volume":"53","author":"Anxionnat","year":"2003","journal-title":"Neurosurgery"},{"key":"2020010206195634400_R3-29","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1111\/j.1540-8183.2001.tb00710.x","article-title":"The use of Amplatzer devices to occlude vascular fistulae","volume":"14","author":"de Giovanni","year":"2001","journal-title":"J Interv Cardiol"},{"key":"2020010206195634400_R4-29","first-page":"113","article-title":"Internal carotid artery sacrifice","volume":"20","author":"Eckard","year":"1994","journal-title":"Compr Ther"},{"key":"2020010206195634400_R5-29","first-page":"238","article-title":"Endovascular carotid occlusion: a retrospective study of complications in 33 cases","volume":"27","author":"Frampas","year":"2000","journal-title":"J Neuroradiol"},{"key":"2020010206195634400_R6-29","first-page":"912","article-title":"Angiographic evidence of aneurysm neck healing following endovascular treatment with bioactive coils","volume":"26","author":"Gonzalez","year":"2005","journal-title":"AJNR Am J Neuroradiol"},{"key":"2020010206195634400_R7-29","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1097\/00006123-199712000-00001","article-title":"Treatment of inoperable carotid aneurysms with endovascular carotid occlusion after extracranial-intracranial bypass surgery","volume":"41","author":"Hacein-Bey","year":"1997","journal-title":"Neurosurgery"},{"key":"2020010206195634400_R8-29","first-page":"773","article-title":"Preliminary experience with an electrolytically detachable fibered coil","volume":"19","author":"Halbach","year":"1998","journal-title":"AJNR Am J Neuroradiol"},{"key":"2020010206195634400_R9-29","first-page":"591","article-title":"Cervical carotid artery aneurysms and pseudoaneurysms. Treatment by balloon embolization therapy","volume":"369","author":"Higashida","year":"1986","journal-title":"Acta Radiol Suppl"},{"key":"2020010206195634400_R10-29","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1002\/ccd.20228","article-title":"New device for percutaneous closure of aortopulmonary collaterals","volume":"63","author":"Hijazi","year":"2004","journal-title":"Catheter Cardiovasc Interv"},{"key":"2020010206195634400_R11-29","first-page":"1409","article-title":"The use of hydrocoil for parent artery occlusion","volume":"25","author":"Kallmes","year":"2004","journal-title":"AJNR Am J Neuroradiol"},{"key":"2020010206195634400_R12-29","first-page":"1580","article-title":"New expandable hydrogel-platinum coil hybrid device for aneurysm embolization","volume":"23","author":"Kallmes","year":"2002","journal-title":"AJNR Am J Neuroradiol"},{"key":"2020010206195634400_R13-29","first-page":"902","article-title":"Parent vessel occlusion for vertebrobasilar fusiform and dissecting aneurysms","volume":"24","author":"Leibowitz","year":"2003","journal-title":"AJNR Am J Neuroradiol"},{"key":"2020010206195634400_R14-29","first-page":"829","article-title":"Stroke risk after abrupt internal carotid artery sacrifice: accuracy of preoperative assessment with balloon test occlusion and stable xenon-enhanced CT","volume":"15","author":"Linskey","year":"1994","journal-title":"AJNR Am J Neuroradiol"},{"key":"2020010206195634400_R15-29","doi-asserted-by":"crossref","first-page":"161","DOI":"10.3171\/jns.2005.102.1.0161","article-title":"Antegrade recanalization of a completely embolized vertebral artery after endovascular treatment of a ruptured intracranial dissecting aneurysm. Report of two cases","volume":"102","author":"Sawada","year":"2005","journal-title":"J Neurosurg"},{"key":"2020010206195634400_R16-29","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1080\/01616412.1980.11739587","article-title":"The role of EC-IC in the treatment of giant intracranial aneurysms","volume":"2","author":"Spetzler","year":"1980","journal-title":"Neurol Res"},{"key":"2020010206195634400_R17-29","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1080\/01616412.1984.11739666","article-title":"Elective EC-IC bypass for unclippable intracranial aneurysms","volume":"6","author":"Spetzler","year":"1984","journal-title":"Neurol Res"},{"key":"2020010206195634400_R18-29","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1007\/BF00596347","article-title":"Balloon occlusion of the internal carotid artery in 40 cases of giant intracavernous aneurysm: Technical aspects, cerebral monitoring, and results","volume":"34","author":"Vazquez Anon","year":"1992","journal-title":"Neuroradiology"},{"key":"2020010206195634400_R19-29","doi-asserted-by":"crossref","first-page":"S30","DOI":"10.1007\/BF02760480","article-title":"Interventional pediatric cardiology: Device closures","volume":"67","author":"Wilkinson","year":"2000","journal-title":"Indian J Pediatr"}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ons\/article-pdf\/59\/suppl_1\/E171\/30216602\/01787389-200607001-00029.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/ons\/article-pdf\/59\/suppl_1\/E171\/30216602\/01787389-200607001-00029.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,19]],"date-time":"2021-11-19T05:56:33Z","timestamp":1637301393000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ons\/article\/59\/suppl_1\/E171\/2281612"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,7,1]]},"references-count":19,"journal-issue":{"issue":"suppl_1","published-print":{"date-parts":[[2006,7,1]]}},"URL":"https:\/\/doi.org\/10.1227\/01.neu.0000219856.66842.ef","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2006,7]]},"published":{"date-parts":[[2006,7,1]]}}}