{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:58:21Z","timestamp":1786125501574,"version":"build-2736575974"},"reference-count":44,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2024,8,5]],"date-time":"2024-08-05T00:00:00Z","timestamp":1722816000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND AND OBJECTIVES:<\/jats:title>\n                    <jats:p>Low-quality data on image-guided external ventricular drain (EVD) accuracy are in large part due to a lack of widespread usage of this system for EVD placement. The potential disconnect between user preferences and existing technologies should be explored to guide future developments. The goal of this study was to survey neurosurgical residents regarding their EVD practices and determine the acceptable amount of setup time for an ideal neuronavigation system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>A 4-question survey was sent to approximately 1512 residents at 108 Acreditation Council for Graduate Medical Education\u2013approved medical doctor neurosurgical training programs in the United States. The responses were received electronically, tabulated, and analyzed using descriptive statistics.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>A total of 130 respondents (9%) completed the survey, reflecting the highest number of neurosurgical resident respondents in an electronic qualitative survey of EVD practices thus far. Residents were willing to accept 6.39 min (SD = 3.73 min) on average for the setup of a bedside EVD image guidance system. The majority chose to use image guidance during EVD placement for cases of narrow slit-like ventricles (86.92%) over intraventricular hemorrhage (13.08%) and hydrocephalus (0%). A total of 90% of all resident respondents misplaced at least 1 EVD with 74% of post-graduate year\u20137 respondents misplacing more than 3 EVDs in their career. A total of 88.46% of respondents deemed more than a single pass as acceptable.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Future EVD neuronavigation technologies should focus on achieving rapid registration times. These systems may be prioritized for patients with anatomic distortions. Current resident attitudes are accepting multiple EVD passes, likely because of the inherent limitations of the traditional freehand approach. Efforts should be made to encourage the best course for the patient.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1227\/neuprac.0000000000000097","type":"journal-article","created":{"date-parts":[[2024,11,14]],"date-time":"2024-11-14T13:03:17Z","timestamp":1731589397000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Resident Opinions on Image Guidance for External Ventricular Drain Placement: A National Survey"],"prefix":"10.1227","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6171-8492","authenticated-orcid":false,"given":"Thomas","family":"Noh","sequence":"first","affiliation":[{"name":"John A Burns School of Medicine, University of Hawaii, Honolulu, Hawaii, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parikshit","family":"Juvekar","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2090-4368","authenticated-orcid":false,"given":"Gina","family":"Watanabe","sequence":"additional","affiliation":[{"name":"John A Burns School of Medicine, University of Hawaii, Honolulu, Hawaii, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandra J.","family":"Golby","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,9]]},"reference":[{"issue":"2","key":"R1-20241114","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1080\/02688690701832084","article-title":"Epidemiology of ventriculostomy in the United States from 1997 to 2001","volume":"22","author":"Sekula","year":"2008","journal-title":"Br J Neurosurg."},{"issue":"3","key":"R2-20241114","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.surneu.2007.05.007","article-title":"A survey of ventriculostomy and intracranial pressure monitor placement practices","volume":"70","author":"O'Neill","year":"2008","journal-title":"Surg Neurol."},{"issue":"1","key":"R3-20241114","doi-asserted-by":"crossref","first-page":"88","DOI":"10.3171\/JNS\/2008\/108\/01\/0088","article-title":"Accuracy of the freehand pass technique for ventriculostomy catheter placement: retrospective assessment using computed tomography scans","volume":"108","author":"Huyette","year":"2008","journal-title":"J Neurosurg."},{"issue":"6","key":"R4-20241114","doi-asserted-by":"crossref","first-page":"1197","DOI":"10.1227\/01.NEU.0000356973.39913.0B","article-title":"External ventricular drain insertion accuracy: is there a need for change in practice?","volume":"65","author":"Toma","year":"2009","journal-title":"Neurosurgery."},{"issue":"9","key":"R5-20241114","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1007\/s00701-013-1769-y","article-title":"Factors associated with external ventricular drain placement accuracy: data from an electronic health record repository","volume":"155","author":"Patil","year":"2013","journal-title":"Acta Neurochir (Wien)."},{"issue":"1","key":"R6-20241114","doi-asserted-by":"crossref","first-page":"289","DOI":"10.3171\/2015.12.JNS152341","article-title":"Risk factors for hemorrhage associated with external ventricular drain placement and removal","volume":"126","author":"Miller","year":"2017","journal-title":"J Neurosurg."},{"issue":"3","key":"R7-20241114","doi-asserted-by":"crossref","first-page":"378","DOI":"10.3171\/jns.2007.106.3.378","article-title":"External ventricular drain infections are independent of drain duration: an argument against elective revision","volume":"106","author":"Lo","year":"2007","journal-title":"J Neurosurg."},{"issue":"3","key":"R8-20241114","doi-asserted-by":"crossref","first-page":"e216","DOI":"10.1016\/j.ijid.2009.04.006","article-title":"Infections associated with indwelling ventriculostomy catheters in a teaching hospital","volume":"14","author":"Chi","year":"2010","journal-title":"Int J Infect Dis."},{"issue":"6","key":"R9-20241114","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1016\/j.clineuro.2011.12.040","article-title":"A US-based survey on ventriculostomy practices","volume":"114","author":"Rehman","year":"2012","journal-title":"Clin Neurol Neurosurg."},{"key":"R10-20241114","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1016\/j.wneu.2019.10.105","article-title":"Causes, complications, and costs associated with external ventricular drainage catheter obstruction","volume":"134","author":"Aten","year":"2020","journal-title":"World Neurosurg."},{"issue":"4","key":"R11-20241114","doi-asserted-by":"crossref","first-page":"1268","DOI":"10.3171\/2017.11.JNS171892","article-title":"Image guidance and improved accuracy of external ventricular drain tip position particularly in patients with small ventricles","volume":"130","author":"Shtaya","year":"2018","journal-title":"J Neurosurg."},{"issue":"3","key":"R12-20241114","doi-asserted-by":"crossref","first-page":"754","DOI":"10.3171\/2015.6.JNS1588","article-title":"App-assisted external ventricular drain insertion","volume":"125","author":"Eftekhar","year":"2016","journal-title":"J Neurosurg."},{"issue":"3","key":"R13-20241114","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1007\/s00701-019-04131-9","article-title":"sEVD\u2014smartphone-navigated placement of external ventricular drains","volume":"162","author":"Eisenring","year":"2020","journal-title":"Acta Neurochir (Wien)."},{"issue":"1","key":"R14-20241114","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1007\/s00381-012-1943-1","article-title":"Smartphone-assisted guide for the placement of ventricular catheters","volume":"29","author":"Thomale","year":"2013","journal-title":"Childs Nerv Syst."},{"issue":"12","key":"R15-20241114","doi-asserted-by":"crossref","first-page":"1718","DOI":"10.1016\/j.jocn.2013.03.005","article-title":"Electromagnetic stereotactic navigation for external ventricular drain placement in the intensive care unit","volume":"20","author":"Mahan","year":"2013","journal-title":"J Clin Neurosci."},{"issue":"6","key":"R16-20241114","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.3171\/2010.3.JNS091237","article-title":"Effect of electromagnetic-navigated shunt placement on failure rates: a prospective multicenter study","volume":"113","author":"Hayhurst","year":"2010","journal-title":"J Neurosurg."},{"issue":"4","key":"R17-20241114","doi-asserted-by":"crossref","first-page":"1127","DOI":"10.1007\/s00701-020-04634-w","article-title":"Neuronavigation-assisted bedside placement of bolt external ventricular drains in the intensive care setting: a technical note","volume":"163","author":"Cabrilo","year":"2021","journal-title":"Acta Neurochir (Wien)."},{"issue":"Apr","key":"R18-20241114","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.jocn.2015.10.018","article-title":"Use of frameless neuronavigation for bedside placement of external ventricular catheters","volume":"26","author":"Glenn","year":"2016","journal-title":"J Clin Neurosci"},{"issue":"5","key":"R19-20241114","doi-asserted-by":"crossref","first-page":"1599","DOI":"10.3171\/2018.4.JNS18124","article-title":"A wearable mixed-reality holographic computer for guiding external ventricular drain insertion at the bedside","volume":"131","author":"Li","year":"2018","journal-title":"J Neurosurg."},{"issue":"4","key":"R20-20241114","doi-asserted-by":"crossref","first-page":"393","DOI":"10.3171\/2015.2.PEDS14387","article-title":"Ultrasound stylet for non-image-guided ventricular catheterization","volume":"16","author":"Coulson","year":"2015","journal-title":"J Neurosurg Pediatr."},{"issue":"5","key":"R21-20241114","doi-asserted-by":"crossref","first-page":"e5","DOI":"10.3171\/2017.7.FOCUS17148","article-title":"Real-time ultrasound-guided external ventricular drain placement: technical note","volume":"43","author":"Manfield","year":"2017","journal-title":"Neurosurg Focus."},{"issue":"2","key":"R22-20241114","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1007\/s12028-011-9571-2","article-title":"Strategic placement of bedside ventriculostomies using ultrasound image guidance: report of three cases","volume":"17","author":"Phillips","year":"2012","journal-title":"Neurocrit Care."},{"issue":"1","key":"R23-20241114","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/s12028-015-0224-8","article-title":"The insertion and management of external ventricular drains: an evidence-based consensus statement: a statement for healthcare professionals from the Neurocritical Care Society","volume":"24","author":"Fried","year":"2016","journal-title":"Neurocrit Care."},{"issue":"4","key":"R24-20241114","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.3171\/2020.8.JNS20321","article-title":"Utility of image-guided external ventriculostomy: analysis of contemporary practice in the United Kingdom and Ireland","volume":"135","author":"McLean","year":"2021","journal-title":"J Neurosurg."},{"issue":"3","key":"R25-20241114","doi-asserted-by":"crossref","first-page":"e34","DOI":"10.2196\/jmir.6.3.e34","article-title":"Improving the quality of web surveys: the Checklist for Reporting Results of Internet E-Surveys (CHERRIES)","volume":"6","author":"Eysenbach","year":"2004","journal-title":"J Med Internet Res."},{"issue":"8","key":"R26-20241114","doi-asserted-by":"crossref","first-page":"1399","DOI":"10.1007\/s00701-017-3201-5","article-title":"Placement accuracy of external ventricular drain when comparing freehand insertion to neuronavigation guidance in severe traumatic brain injury","volume":"159","author":"AlAzri","year":"2017","journal-title":"Acta Neurochir."},{"key":"R27-20241114","doi-asserted-by":"crossref","first-page":"e329","DOI":"10.1016\/j.wneu.2021.09.060","article-title":"Is image guidance essential for external ventricular drain insertion?","volume":"156","author":"Fisher","year":"2021","journal-title":"World Neurosurg."},{"issue":"1","key":"R28-20241114","doi-asserted-by":"crossref","first-page":"66","DOI":"10.3171\/2012.11.JNS111384","article-title":"Comparison of the accuracy of ventricular catheter placement using freehand placement, ultrasonic guidance, and stereotactic neuronavigation","volume":"119","author":"Wilson","year":"2013","journal-title":"J Neurosurg."},{"issue":"Dec","key":"R29-20241114","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.jocn.2021.10.014","article-title":"Systematic review and meta-analysis of external ventricular drain placement accuracy and narrative review of guidance devices","volume":"94","author":"Stuart","year":"2021","journal-title":"J Clin Neurosci"},{"issue":"1","key":"R30-20241114","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1159\/000368906","article-title":"Smart stylet: the development and use of a bedside external ventricular drain image-guidance system","volume":"93","author":"Patil","year":"2015","journal-title":"Stereotact Funct Neurosurg."},{"issue":"5","key":"R31-20241114","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1007\/s00701-019-03867-8","article-title":"Current accuracy of surface matching compared to adhesive markers in patient-to-image registration","volume":"161","author":"Mongen","year":"2019","journal-title":"Acta Neurochir (Wien)."},{"issue":"1","key":"R32-20241114","doi-asserted-by":"crossref","first-page":"14894","DOI":"10.1038\/s41598-018-32424-z","article-title":"High speed, high density intraoperative 3D optical topographical imaging with efficient registration to MRI and CT for craniospinal surgical navigation","volume":"8","author":"Jakubovic","year":"2018","journal-title":"Sci Rep."},{"key":"R33-20241114","doi-asserted-by":"crossref","first-page":"e863","DOI":"10.1016\/j.wneu.2019.01.201","article-title":"Optical topographic imaging for spinal intraoperative three-dimensional navigation in mini-open approaches: a prospective cohort study of initial preclinical and clinical feasibility","volume":"125","author":"Guha","year":"2019","journal-title":"World Neurosurg."},{"issue":"5","key":"R35-20241114","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.3171\/2021.5.JNS211033","article-title":"Frameless neuronavigation with computer vision and real-time tracking for bedside external ventricular drain placement: a cadaveric study","volume":"136","author":"Robertson","year":"2022","journal-title":"J Neurosurg."},{"issue":"1","key":"R36-20241114","doi-asserted-by":"crossref","first-page":"e16","DOI":"10.3171\/2020.10.FOCUS20779","article-title":"Augmented reality-assisted ventriculostomy","volume":"50","author":"Schneider","year":"2021","journal-title":"Neurosurg Focus."},{"issue":"2","key":"R37-20241114","doi-asserted-by":"crossref","first-page":"157","DOI":"10.3171\/jns.1982.57.2.0157","article-title":"Intraoperative use of real-time ultrasonography in neurosurgery","volume":"57","author":"Chandler","year":"1982","journal-title":"J Neurosurg."},{"issue":"2","key":"R38-20241114","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1159\/000120646","article-title":"Intraoperative uses of ultrasound in the pediatric neurosurgical patient","volume":"18","author":"Babcock","year":"1992","journal-title":"Pediatr Neurosurg."},{"issue":"2","key":"R39-20241114","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/S0090-3019(00)00267-6","article-title":"Ultrasound-based navigation during intracranial burr hole procedures: experience in a series of 100 cases","volume":"54","author":"Strowitzki","year":"2000","journal-title":"Surg Neurol."},{"issue":"2","key":"R40-20241114","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/j.wneu.2013.01.039","article-title":"Intraoperative ultrasound guidance for the placement of permanent ventricular cerebrospinal fluid shunt catheters: a single-center historical cohort study","volume":"81","author":"Crowley","year":"2014","journal-title":"World Neurosurg."},{"issue":"5 Suppl","key":"R41-20241114","first-page":"406","article-title":"Accurate placement of cerebrospinal fluid shunt ventricular catheters with real-time ultrasound guidance in older children without patent fontanelles: technical note","volume":"107","author":"Whitehead","year":"2007","journal-title":"J Neurosurg."},{"key":"R1a-20241114","doi-asserted-by":"crossref","first-page":"708531","DOI":"10.1155\/2014\/708531","article-title":"External ventricular drain infections: risk factors and outcome","volume":"2014","author":"Hagel","year":"2014","journal-title":"Interdiscip Perspect Infect Dis."},{"issue":"2","key":"R2a-20241114","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1227\/NEU.0b013e31821a45ba","article-title":"Meta-analysis of hemorrhagic complications from ventriculostomy placement by neurosurgeons","volume":"69","author":"Bauer","year":"2011","journal-title":"Neurosurgery."},{"issue":"10","key":"R3a-20241114","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.1001\/jama.2016.11698","article-title":"From volume to value in health care: the work begins","volume":"316","author":"Porter","year":"2016","journal-title":"JAMA."},{"issue":"1","key":"R4a-20241114","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1007\/s12028-017-0492-6","article-title":"The incidence of catheter tract hemorrhage and catheter placement accuracy in the CLEAR III trial","volume":"29","author":"Muller","year":"2018","journal-title":"Neurocrit Care."}],"container-title":["Neurosurgery Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1227\/neuprac.0000000000000097","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:56:36Z","timestamp":1786121796000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1227\/neuprac.0000000000000097"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,5]]},"references-count":44,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1227\/neuprac.0000000000000097","relation":{},"ISSN":["2834-4383"],"issn-type":[{"value":"2834-4383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,5]]},"assertion":[{"value":"2023-08-25","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-04-16","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}