{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T18:03:09Z","timestamp":1786125789582,"version":"build-2736575974"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>S2 alar-iliac (S2AI) screws provide spinopelvic fixation with the advantages of minimized dissection, easier rod contouring, and decreased symptomatic screw-head prominence. However, placement of S2AI screws may be challenging because of the anatomy of the lumbosacral junction. Augmented reality is a nascent technology that may enhance placement of S2AI screws.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>OBJECTIVE:<\/jats:title>\n                    <jats:p>To report the first in-human placement of augmented reality (AR)\u2013assisted S2 alar-iliac screws and evaluate the accuracy of screw placement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>A retrospective review was performed of patients who underwent AR-assisted S2AI screw placement. All surgeries were performed by 2 neurosurgeons using an AR head-mounted display (Xvision, Augmedics). Screw accuracy was analyzed in a blinded fashion by an independent neuroradiologist using the cortical breach grading scale.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>Twelve patients underwent AR-assisted S2AI screw placement for a total of 23 screws. Indications for surgery included deformity, degenerative disease, and tumor. Twenty-two screws (95.6%) were accurate\u2014defined as grade 0 or grade 1. Twenty-one screws (91.3%) were classified as grade 0, 1 screw (4.3%) was grade 1, and 1 screw (4.3%) was grade 3. All breaches were asymptomatic.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>\n                      AR-assisted S2AI screw placement had an overall accuracy rate of 95.6% (grade 0 and grade 1 screws) in a cohort of 12 patients and 23 screws. This compares favorably with freehand and robotic placement.\n                      <jats:sup>1,2<\/jats:sup>\n                      AR enables spine surgeons to both better visualize anatomy and accurately place spinal instrumentation. Future studies are warranted to research the learning curve and cost analysis of AR-assisted spine surgery.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1227\/ons.0000000000000439","type":"journal-article","created":{"date-parts":[[2022,12,15]],"date-time":"2022-12-15T10:35:48Z","timestamp":1671100548000},"page":"68-73","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":17,"title":["In-Human Report of S2 Alar-Iliac Screw Placement Using Augmented Reality Assistance"],"prefix":"10.1227","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4981-1408","authenticated-orcid":false,"given":"Brendan F.","family":"Judy","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ann","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yike","family":"Jin","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles","family":"Ronkon","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Majid","family":"Khan","sequence":"additional","affiliation":[{"name":"Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ethan","family":"Cottrill","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeff","family":"Ehresman","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zach","family":"Pennington","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Bydon","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheng-Fu L.","family":"Lo","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Zucker School of Medicine at Hofstra, Long Island Jewish Medical Center and North Shore University Hospital, Northwell Health, Manhasset, New York, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel M.","family":"Sciubba","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Zucker School of Medicine at Hofstra, Long Island Jewish Medical Center and North Shore University Hospital, Northwell Health, Manhasset, New York, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Camilo A.","family":"Molina","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Washington University School of Medicine, St. Louis, Missouri, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9397-8344","authenticated-orcid":false,"given":"Timothy F.","family":"Witham","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,11,4]]},"reference":[{"issue":"4","key":"R1-20250820","doi-asserted-by":"crossref","first-page":"334","DOI":"10.2106\/JBJS.17.00052","article-title":"The free-hand technique for S2-alar-iliac screw placement: a safe and effective method for sacropelvic fixation in adult spinal deformity","volume":"100","author":"Shillingford","year":"2018","journal-title":"J Bone Joint Surg Am."},{"issue":"21","key":"R2-20250820","doi-asserted-by":"crossref","first-page":"E1297","DOI":"10.1097\/BRS.0000000000002694","article-title":"Human versus robot: a propensity-matched analysis of the accuracy of free hand versus robotic guidance for placement of S2 alar-iliac (S2AI) screws","volume":"43","author":"Shillingford","year":"2018","journal-title":"Spine (Phila Pa 1976)."},{"issue":"3","key":"R3-20250820","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1097\/01.brs.0000197193.81296.f1","article-title":"Minimum 5-year analysis of L5-S1 fusion using sacropelvic fixation (bilateral S1 and iliac screws) for spinal deformity","volume":"31","author":"Tsuchiya","year":"2006","journal-title":"Spine (Phila Pa 1976)."},{"issue":"6","key":"R4-20250820","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1177\/2192568218759037","article-title":"Biomechanics of L5\/S1 in long thoracolumbosacral constructs: a cadaveric study","volume":"8","author":"Lee","year":"2018","journal-title":"Global Spine J."},{"issue":"21","key":"R5-20250820","doi-asserted-by":"crossref","first-page":"2321","DOI":"10.1097\/00007632-200211010-00004","article-title":"Biomechanical evaluation of lumbosacral reconstruction techniques for spondylolisthesis: an in vitro porcine model","volume":"27","author":"Cunningham","year":"2002","journal-title":"Spine (Phila Pa 1976)."},{"issue":"24","key":"R6-20250820","doi-asserted-by":"crossref","first-page":"866","DOI":"10.1097\/BRS.0b013e3181bf94f0","article-title":"A biomechanical comparison of different types of lumbopelvic fixation","volume":"34","author":"Tis","year":"2009","journal-title":"Spine (Phila Pa 1976)."},{"key":"R7-20250820","first-page":"83","article-title":"The S2 portal to the ilium","volume":"2","author":"Sponseller","year":"2007","journal-title":"Semin Spine Surg."},{"issue":"5","key":"R8-20250820","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1097\/BRS.0b013e318194128c","article-title":"Low profile pelvic fixation: anatomic parameters for sacral alar-iliac fixation versus traditional iliac fixation","volume":"34","author":"Chang","year":"2009","journal-title":"Spine (Phila Pa 1976)."},{"key":"R9-20250820","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/j.wneu.2016.06.042","article-title":"S2-alar-iliac screws are associated with lower rate of symptomatic screw prominence than iliac screws: radiographic analysis of minimal distance from screw head to skin","volume":"93","author":"Ishida","year":"2016","journal-title":"World Neurosurg."},{"issue":"3","key":"R10-20250820","doi-asserted-by":"crossref","first-page":"326","DOI":"10.21037\/jss-21-14","article-title":"The accuracy of robot-assisted S2 alar-iliac screw placement at two different healthcare centers","volume":"7","author":"Lee","year":"2021","journal-title":"J Spine Surg."},{"issue":"1","key":"R11-20250820","doi-asserted-by":"crossref","first-page":"161","DOI":"10.14444\/8021","article-title":"Augmented reality navigated sacral-alar-iliac screw insertion","volume":"15","author":"Dennler","year":"2021","journal-title":"Int J Spine Surg."},{"issue":"5","key":"R12-20250820","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1049\/htl.2017.0062","article-title":"Quantifying attention shifts in augmented reality image-guided neurosurgery","volume":"4","author":"Leger","year":"2017","journal-title":"Healthc Technol Lett."},{"issue":"3","key":"R13-20250820","doi-asserted-by":"crossref","first-page":"E3","DOI":"10.3171\/2014.1.FOCUS13516","article-title":"Intraoperative image-guided spinal navigation: technical pitfalls and their avoidance","volume":"36","author":"Rahmathulla","year":"2014","journal-title":"Neurosurg Focus."},{"issue":"3","key":"R14-20250820","doi-asserted-by":"crossref","first-page":"351","DOI":"10.3171\/2021.2.SPINE202097","article-title":"Clinical accuracy and initial experience with augmented reality-assisted pedicle screw placement: the first 205 screws","volume":"36","author":"Liu","year":"2021","journal-title":"J Neurosurg Spine"},{"issue":"2","key":"R15-20250820","doi-asserted-by":"crossref","first-page":"E10","DOI":"10.3171\/2021.5.FOCUS21217","article-title":"First in-human report of the clinical accuracy of thoracolumbar percutaneous pedicle screw placement using augmented reality guidance","volume":"51","author":"Yahanda","year":"2021","journal-title":"Neurosurg Focus."},{"issue":"3","key":"R16-20250820","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1093\/ons\/opaa398","article-title":"Clinical accuracy, technical precision, and workflow of the first in human use of an augmented-reality head-mounted display stereotactic navigation system for spine surgery","volume":"20","author":"Molina","year":"2021","journal-title":"Oper Neurosurg."},{"issue":"5","key":"R17-20250820","doi-asserted-by":"crossref","first-page":"700","DOI":"10.3171\/2020.9.SPINE201219","article-title":"Augmented reality mediated stereotactic navigation for execution of en bloc lumbar spondylectomy osteotomies","volume":"34","author":"Molina","year":"2021","journal-title":"J Neurosurg Spine."},{"issue":"1","key":"R18-20250820","doi-asserted-by":"crossref","first-page":"7","DOI":"10.14245\/kjs.2013.10.1.7","article-title":"Technical report of free hand pedicle screw placement using the entry points with junction of proximal edge of transverse process and lamina in lumbar spine: analysis of 2601 consecutive screws","volume":"10","author":"Oh","year":"2013","journal-title":"Korean J Spine."},{"key":"R19-20250820","doi-asserted-by":"crossref","first-page":"e108","DOI":"10.1016\/j.wneu.2018.04.095","article-title":"Neurovascular relationships of S2AI screw placement: anatomic study","volume":"116","author":"Abdul-Jabbar","year":"2018","journal-title":"World Neurosurg."},{"issue":"7","key":"R20-20250820","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1177\/2192568217700111","article-title":"Comparison between S2-alar-iliac screw fixation and iliac screw fixation in adult deformity surgery: reoperation rates and spinopelvic parameters","volume":"7","author":"Ishida","year":"2017","journal-title":"Global Spine J."},{"issue":"4","key":"R21-20250820","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1097\/BSD.0000000000000222","article-title":"A comparison of early clinical and radiographic complications of iliac screw fixation versus S2 alar iliac (S2AI) fixation in the adult and pediatric populations","volume":"28","author":"Ilyas","year":"2015","journal-title":"J Spinal Disord Tech."},{"issue":"3","key":"R22-20250820","doi-asserted-by":"crossref","first-page":"E142","DOI":"10.1097\/BRS.0000000000001722","article-title":"Use of S2-alar-iliac screws associated with less complications than iliac screws in adult lumbosacropelvic fixation","volume":"42","author":"Elder","year":"2017","journal-title":"Spine (Phila Pa 1976)."},{"issue":"1","key":"R23-20250820","doi-asserted-by":"crossref","first-page":"155","DOI":"10.21037\/jss.2019.02.04","article-title":"What should my hospital buy next?-guidelines for the acquisition and application of imaging, navigation, and robotics for spine surgery","volume":"5","author":"Malham","year":"2019","journal-title":"J Spine Surg."},{"key":"R24-20250820","doi-asserted-by":"crossref","first-page":"e635","DOI":"10.1016\/j.wneu.2020.01.119","article-title":"Robot-assisted versus freehand instrumentation in short-segment lumbar fusion: experience with real-time image-guided spinal robot","volume":"136","author":"Jiang","year":"2020","journal-title":"World Neurosurg."}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000000439","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:01:09Z","timestamp":1786122069000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000000439"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,4]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1227\/ons.0000000000000439","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,4]]},"assertion":[{"value":"2022-01-24","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-07-29","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}