{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T18:03:07Z","timestamp":1786125787710,"version":"build-2736575974"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>The use of modern transfemoral balloon guide catheters (BGC) for flow reversal during carotid artery stenting is scarcely described in the literature but represents a promising and efficient technique for embolic protection.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>OBJECTIVE:<\/jats:title>\n                    <jats:p>To describe a flow-reversal technique using the Walrus BGC (Q'Apel Medical Inc.) and report our center's experience.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>We performed a retrospective analysis of data for consecutive patients aged 18 years or older who underwent elective carotid artery stenting with the use of flow reversal through the Walrus BGC between July 2020 and September 2021. Patient characteristics, procedural details, and clinical follow-up were evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>One hundred and five patients were included. Mean age was 69.8 \u00b1 9.4 years, and 36 (34.3%) were women. The most common comorbidities were hyperlipidemia (76.2%) and hypertension (57.1%). Fifty-nine (56.2%) patients were symptomatic. Ninety-nine (94.3%) patients had stenosis \u226570%. Contralateral stenosis \u226550% was present in 44 patients (41.9%). Distal filters were used after flow reversal was established in 90 patients (85.7%). Angioplasty was performed in 85 patients (80.9%). Stenting was successful in 100% of cases. No periprocedural transient ischemic attacks (TIAs) or strokes occurred. Stroke occurred in 2 patients (1.9%) during the 30-day follow-up period, resulting in 1 (0.9%) death.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>In our experience, this technique was safe, feasible, and efficient, with 100% technical success and no periprocedural thromboembolic complications. More extensive studies are needed to establish the role of proximal protection with flow reversal using modern BGCs.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1227\/ons.0000000000000442","type":"journal-article","created":{"date-parts":[[2022,10,17]],"date-time":"2022-10-17T12:12:28Z","timestamp":1666008748000},"page":"11-16","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["Carotid Artery Stenting Using the Walrus Balloon Guide Catheter With Flow Reversal for Proximal Embolic Protection: Technical Description and Single-Center Case Series"],"prefix":"10.1227","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5794-3339","authenticated-orcid":false,"given":"Justin M.","family":"Cappuzzo","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA;"},{"name":"Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andre","family":"Monteiro","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA;"},{"name":"Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad","family":"Waqas","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA;"},{"name":"Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ammad A.","family":"Baig","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA;"},{"name":"Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel O.","family":"Popoola","sequence":"additional","affiliation":[{"name":"Jacobs School of Medicine, University at Buffalo, Buffalo, New York, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Faisal","family":"Almayman","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA;"},{"name":"Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wasiq I.","family":"Khawar","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zoe G.","family":"Farkash","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason M.","family":"Davies","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA;"},{"name":"Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York, USA;"},{"name":"Department of Bioinformatics, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA;"},{"name":"Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, New York, USA;"},{"name":"Jacobs Institute, Buffalo, New York, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adnan H.","family":"Siddiqui","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA;"},{"name":"Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York, USA;"},{"name":"Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, New York, USA;"},{"name":"Jacobs Institute, Buffalo, New York, USA;"},{"name":"Department of Radiology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6208-3724","authenticated-orcid":false,"given":"Elad I.","family":"Levy","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA;"},{"name":"Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York, USA;"},{"name":"Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, New York, USA;"},{"name":"Jacobs Institute, Buffalo, New York, USA;"},{"name":"Department of Radiology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth V.","family":"Snyder","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA;"},{"name":"Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York, USA;"},{"name":"Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, New York, USA;"},{"name":"Jacobs Institute, Buffalo, New York, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,10,17]]},"reference":[{"issue":"7","key":"R1-20250820","doi-asserted-by":"crossref","first-page":"e364","DOI":"10.1161\/STR.0000000000000375","article-title":"2021 guideline for the prevention of stroke in patients with stroke and transient ischemic attack: a guideline from the American heart association\/American stroke association","volume":"52","author":"Kleindorfer","year":"2021","journal-title":"Stroke."},{"issue":"1","key":"R2-20250820","first-page":"11","article-title":"Factors associated with increased rates of post-procedural stroke or death following carotid artery stent placement: a systematic review","volume":"7","author":"Khan","year":"2014","journal-title":"J Vasc Interv Neurol."},{"issue":"5 pt A","key":"R3-20250820","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.carrev.2017.12.010","article-title":"Proximal embolic protection versus distal filter protection versus combined protection in carotid artery stenting: a systematic review and meta-analysis","volume":"19","author":"Texakalidis","year":"2018","journal-title":"Cardiovasc Revasc Med."},{"issue":"1","key":"R4-20250820","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1053\/j.semvascsurg.2018.03.002","article-title":"The history of proximal carotid protection and flow reversal to prevent stent angioplasty embolization","volume":"31","author":"Parodi","year":"2018","journal-title":"Semin Vasc Surg."},{"issue":"23","key":"R5-20250820","doi-asserted-by":"crossref","first-page":"2313","DOI":"10.1001\/jama.2019.18441","article-title":"Association of transcarotid artery revascularization vs transfemoral carotid artery stenting with stroke or death among patients with carotid artery stenosis","volume":"322","author":"Schermerhorn","year":"2019","journal-title":"JAMA"},{"issue":"1","key":"R6-20250820","first-page":"1","article-title":"Safety and effectiveness of the INVATEC MO.MA proximal cerebral protection device during carotid artery stenting: results from the ARMOUR pivotal trial","volume":"76","author":"Ansel","year":"2010","journal-title":"Catheter Cardiovasc Interv."},{"issue":"1","key":"R7-20250820","first-page":"E71","article-title":"Common carotid artery endovascular clamping for neuroprotection during carotid stenting: flow-gate system as an innovative treatment approach","volume":"97","author":"Gabrielli","year":"2021","journal-title":"Catheter Cardiovasc Interv."},{"issue":"2","key":"R8-20250820","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1007\/s00062-019-00770-8","article-title":"Angiographic patterns and outcomes achieved by proximal balloon occlusion in symptomatic carotid artery stenosis stenting","volume":"30","author":"Dargazanli","year":"2020","journal-title":"Clin Neuroradiol."},{"issue":"3","key":"R9-20250820","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1136\/neurintsurg-2021-017494","article-title":"Walrus large bore guide catheter impact on recanalization first pass effect and outcomes: the WICkED study","volume":"14","author":"Cortez","year":"2021","journal-title":"J Neurointerv Surg."},{"key":"R10-20250820","doi-asserted-by":"crossref","first-page":"e144","DOI":"10.1016\/j.wneu.2021.05.051","article-title":"Walrus balloon guide catheter for stroke intervention: technical considerations and clinical outcomes","volume":"152","author":"Dossani","year":"2021","journal-title":"World Neurosurg."},{"issue":"7","key":"R11-20250820","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1056\/NEJM199108153250701","article-title":"Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis","volume":"325","author":"Barnett","year":"1991","journal-title":"N Engl J Med."},{"issue":"9","key":"R12-20250820","first-page":"1830","article-title":"Cerebral ischemia after filter-protected carotid artery stenting is common and cannot be predicted by the presence of substantial amount of debris captured by the filter device","volume":"27","author":"Maleux","year":"2006","journal-title":"AJNR Am J Neuroradiol."},{"issue":"2","key":"R13-20250820","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1016\/j.ijcard.2014.07.241","article-title":"Cerebral microemboli and neurocognitive change after carotid artery stenting with different embolic protection devices","volume":"176","author":"Akkaya","year":"2014","journal-title":"Int J Cardiol."},{"issue":"6","key":"R14-20250820","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1159\/000489711","article-title":"Carotid revascularization with and without the use of an embolic protection device: a single-center experience from Pakistan","volume":"7","author":"Bashir","year":"2018","journal-title":"Interv Neurol."},{"issue":"15","key":"R15-20250820","doi-asserted-by":"crossref","first-page":"1383","DOI":"10.1016\/j.jacc.2011.11.035","article-title":"The PROFI study (prevention of cerebral embolization by proximal balloon occlusion compared to filter protection during carotid artery stenting): a prospective randomized trial","volume":"59","author":"Bijuklic","year":"2012","journal-title":"J Am Coll Cardiol."},{"issue":"1","key":"R16-20250820","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1177\/152660280200900104","article-title":"\u201cSeat belt and air bag\u201d technique for cerebral protection during carotid stenting","volume":"9","author":"Parodi","year":"2002","journal-title":"J Endovasc Ther."},{"issue":"23","key":"R17-20250820","doi-asserted-by":"crossref","first-page":"2791","DOI":"10.1161\/hc4801.100353","article-title":"Balloon-protected carotid artery stenting: relationship of periprocedural neurological complications with the size of particulate debris","volume":"104","author":"T\u00fcbler","year":"2001","journal-title":"Circulation."},{"issue":"3","key":"R18-20250820","first-page":"221","article-title":"Comparison of anti-embolic protection with proximal balloon occlusion and filter devices during carotid artery stenting: clinical and procedural outcomes","volume":"9","author":"Tatli","year":"2013","journal-title":"Postepy Kardiol Interwencyjnej."},{"issue":"11","key":"R19-20250820","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1016\/j.jcin.2013.07.006","article-title":"Randomized comparison of distal and proximal cerebral protection during carotid artery stenting","volume":"6","author":"Cano","year":"2013","journal-title":"JACC Cardiovasc Interv."},{"issue":"5","key":"R20-20250820","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/j.ejvs.2021.01.039","article-title":"Editor's choice - early and late outcomes after transcarotid revascularisation for internal carotid artery stenosis: a systematic review and meta-analysis","volume":"61","author":"Galyfos","year":"2021","journal-title":"Eur J Vasc Endovasc Surg."}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000000442","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:01:06Z","timestamp":1786122066000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000000442"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,17]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1227\/ons.0000000000000442","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,17]]},"assertion":[{"value":"2022-01-24","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-07-12","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}