{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T18:03:16Z","timestamp":1786125796123,"version":"build-2736575974"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,10]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND AND OBJECTIVES:<\/jats:title>\n                    <jats:p>Three-dimensional imaging-based navigation in spine surgery is mostly applied for pedicle screw placement. However, its potential reaches beyond. In this study, we analyzed the incorporation of spinal navigation for lateral instrumentation of the thoracolumbar spine in clinical routine at a high-volume spine center.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>Patients scheduled for lateral instrumentation were prospectively enrolled. A reference array was attached to the pelvis, and a computed tomography scan was acquired intraoperatively. A control computed tomography scan was routinely performed after final cage placement, replacing conventional 2-dimensional X-ray imaging.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>145 cases were enrolled from April to October 2021 with a median of 1 (1-4) level being instrumented. Indications for surgery were trauma (35.9%), spinal infection (31.7%), primary and secondary tumors of the spine (17.2%), and degenerative spine disease (15.2%). The duration of surgery after the first scan was 98 \u00b1 41 (20-342) minutes. In total, 190 cages were implanted (94 expandable cages for vertebral body replacement (49.5%) and 96 cages for interbody fusion [50.5%]). Navigation was successfully performed in 139 cases (95.9%). The intraoperative mental load was rated on a scale from 0 to 150 (maximal effort) by the surgeons, showing a moderate effort (median 30 [10-120]).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Three-dimensional imaging-based spinal navigation can easily be incorporated in clinical routine and serves as a reliable tool to achieve precise implant placement in lateral instrumentation of the spine. It helps to minimize radiation exposure to the surgical staff.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1227\/ons.0000000000000803","type":"journal-article","created":{"date-parts":[[2023,7,13]],"date-time":"2023-07-13T18:01:11Z","timestamp":1689271271000},"page":"303-310","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Spinal Navigation for Lateral Instrumentation of the Thoracolumbar Spine"],"prefix":"10.1227","volume":"25","author":[{"given":"Maximilian","family":"Schwendner","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Technical University of Munich, Germany, School of Medicine, Klinikum rechts der Isar, Munich, Germany;"},{"name":"TUM-Neuroimaging Center, Technical University of Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raimunde","family":"Liang","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Technical University of Munich, Germany, School of Medicine, Klinikum rechts der Isar, Munich, Germany;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vicki M.","family":"Butensch\u00f6en","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Technical University of Munich, Germany, School of Medicine, Klinikum rechts der Isar, Munich, Germany;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4050-1531","authenticated-orcid":false,"given":"Sandro M.","family":"Krieg","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Technical University of Munich, Germany, School of Medicine, Klinikum rechts der Isar, Munich, Germany;"},{"name":"TUM-Neuroimaging Center, Technical University of Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Ille","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Technical University of Munich, Germany, School of Medicine, Klinikum rechts der Isar, Munich, Germany;"},{"name":"TUM-Neuroimaging Center, Technical University of Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernhard","family":"Meyer","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Technical University of Munich, Germany, School of Medicine, Klinikum rechts der Isar, Munich, Germany;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,7,13]]},"reference":[{"issue":"1","key":"R1-20250820","doi-asserted-by":"crossref","first-page":"e10","DOI":"10.3171\/2021.10.FOCUS21509","article-title":"Evaluating robotic pedicle screw placement against conventional modalities: a systematic review and network meta-analysis","volume":"52","author":"Naik","year":"2022","journal-title":"Neurosurg Focus"},{"issue":"3","key":"R2-20250820","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1007\/s10143-015-0679-2","article-title":"Computer navigation versus fluoroscopy-guided navigation for thoracic pedicle screw placement: a meta-analysis","volume":"39","author":"Meng","year":"2016","journal-title":"Neurosurg Rev"},{"issue":"2","key":"R3-20250820","doi-asserted-by":"crossref","first-page":"113","DOI":"10.3171\/2012.5.SPINE11399","article-title":"Pedicle screw navigation: a systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion","volume":"17","author":"Shin","year":"2012","journal-title":"J Neurosurg Spine"},{"issue":"13","key":"R4-20250820","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1097\/BRS.0000000000000351","article-title":"Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: a prospective randomized comparison of navigated versus non-navigated freehand techniques","volume":"39","author":"Villard","year":"2014","journal-title":"Spine"},{"issue":"3","key":"R5-20250820","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.spinee.2014.10.003","article-title":"Learning curve of 3D fluoroscopy image-guided pedicle screw placement in the thoracolumbar spine","volume":"15","author":"Ryang","year":"2015","journal-title":"Spine J"},{"key":"R6-20250820","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.wneu.2017.01.025","article-title":"Total navigation in spine surgery; a concise guide to eliminate fluoroscopy using a portable intraoperative computed tomography 3-dimensional navigation system","volume":"100","author":"Navarro-Ramirez","year":"2017","journal-title":"World Neurosurg"},{"issue":"1","key":"R7-20250820","doi-asserted-by":"crossref","first-page":"50","DOI":"10.3171\/spi.2002.96.1.0050","article-title":"Retroperitoneal lateral lumbar interbody fusion with titanium threaded fusion cages","volume":"96","author":"Wolfla","year":"2002","journal-title":"J Neurosurg Spine"},{"issue":"4","key":"R9-20250820","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/j.spinee.2005.08.012","article-title":"Extreme lateral interbody fusion (XLIF): a novel surgical technique for anterior lumbar interbody fusion","volume":"6","author":"Ozgur","year":"2006","journal-title":"Spine J"},{"key":"R10-20250820","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1100\/2012\/680643","article-title":"Clinical outcomes of extreme lateral interbody fusion in the treatment of adult degenerative scoliosis","volume":"2012","author":"Caputo","year":"2012","journal-title":"Sci World J"},{"issue":"2","key":"R11-20250820","doi-asserted-by":"crossref","first-page":"e5","DOI":"10.3171\/2014.6.FOCUS14150","article-title":"Direct lateral retroperitoneal approach for the surgical treatment of lumbar discitis and osteomyelitis","volume":"37","author":"Madhavan","year":"2014","journal-title":"Neurosurg Focus"},{"issue":"6","key":"R12-20250820","doi-asserted-by":"crossref","first-page":"102","DOI":"10.21037\/atm.2018.02.10","article-title":"Minimally invasive surgery for thoracolumbar spinal trauma","volume":"6","author":"Walker","year":"2018","journal-title":"Ann Transl Med"},{"issue":"3","key":"R13-20250820","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1097\/BRS.0000000000004177","article-title":"Integrated custom composite polyetheretherketone\/carbon fiber (PEEK\/CF) vertebral body replacement (VBR) in the treatment of bone tumors of the spine: a preliminary report from a multicenter study","volume":"47","author":"Shen","year":"2022","journal-title":"Spine"},{"issue":"10","key":"R14-20250820","doi-asserted-by":"crossref","first-page":"1197","DOI":"10.1097\/00007632-200105150-00024","article-title":"Image-guided anterior thoracolumbar corpectomy: a report of three cases","volume":"26","author":"Ohmori","year":"2001","journal-title":"Spine"},{"issue":"2","key":"R15-20250820","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1227\/NEU.0000000000000726","article-title":"Three-dimensional computed tomography-based spinal navigation in minimally invasive lateral lumbar interbody fusion: feasibility, technique, and initial results","volume":"11","author":"Park","year":"2015","journal-title":"Oper Neurosurg"},{"issue":"5","key":"R16-20250820","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1002\/bjs.10795","article-title":"Systematic review of measurement tools to assess surgeons' intraoperative cognitive workload","volume":"105","author":"Dias","year":"2018","journal-title":"Br J Surg"},{"issue":"4","key":"R17-20250820","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1097\/SLA.0000000000002289","article-title":"Temporal stress in the operating room: brain engagement promotes \u201ccoping\u201d and disengagement prompts \u201cchoking\u201d","volume":"267","author":"Modi","year":"2018","journal-title":"Ann Surg"},{"issue":"2","key":"R18-20250820","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.surg.2005.07.037","article-title":"A prospective study of patient safety in the operating room","volume":"139","author":"Christian","year":"2006","journal-title":"Surgery"},{"issue":"3","key":"R19-20250820","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/j.jsurg.2022.12.010","article-title":"Cognitive load management: an invaluable tool for safe and effective surgical training","volume":"80","author":"Howie","year":"2023","journal-title":"J Surg Educ"},{"issue":"2","key":"R21-20250820","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1007\/s00132-014-3070-z","article-title":"[Extreme lateral interbody fusion. Indication, surgical technique, outcomes and specific complications]","volume":"44","author":"Quante","year":"2015","journal-title":"Der Orthop\u00e4de"},{"issue":"3","key":"R22-20250820","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1007\/s00701-014-2248-9","article-title":"Extreme lateral interbody fusion (XLIF\u00ae): how I do it","volume":"157","author":"Berjano","year":"2015","journal-title":"Acta Neurochir"},{"issue":"4","key":"R23-20250820","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.esas.2010.09.002","article-title":"Navigation-assisted fluoroscopy in minimally invasive direct lateral interbody fusion: a cadaveric study","volume":"4","author":"Webb","year":"2010","journal-title":"SAS J"},{"issue":"7","key":"R24-20250820","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1177\/2192568217716149","article-title":"Comparison perioperative factors during minimally invasive pre-psoas lateral interbody fusion of the lumbar spine using either navigation or conventional fluoroscopy","volume":"7","author":"Zhang","year":"2017","journal-title":"Global Spine J"},{"key":"R25-20250820","doi-asserted-by":"crossref","first-page":"e1266","DOI":"10.1016\/j.wneu.2018.11.027","article-title":"Minimally invasive thoracolumbar corpectomy and stabilization for unstable burst fractures using intraoperative computed tomography and computer-assisted spinal navigation","volume":"122","author":"Yu","year":"2019","journal-title":"World Neurosurg"},{"issue":"6","key":"R26-20250820","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1093\/ons\/opx176","article-title":"Analysis of intraoperative cone-beam computed tomography combined with image guidance for lateral lumbar interbody fusion","volume":"14","author":"Liu","year":"2018","journal-title":"Oper Neurosurg"},{"issue":"3","key":"R27-20250820","doi-asserted-by":"crossref","first-page":"339","DOI":"10.3171\/2016.2.SPINE151295","article-title":"Use of 3D CT-based navigation in minimally invasive lateral lumbar interbody fusion","volume":"25","author":"Joseph","year":"2016","journal-title":"J Neurosurg Spine"},{"issue":"3","key":"R28-20250820","doi-asserted-by":"crossref","first-page":"364","DOI":"10.3390\/medicina58030364","article-title":"Comparison of navigated expandable vertebral cage with conventional expandable vertebral cage for minimally invasive lumbar\/thoracolumbar corpectomy","volume":"58","author":"Tanaka","year":"2022","journal-title":"Medicina (Kaunas)"},{"issue":"1","key":"R29-20250820","doi-asserted-by":"crossref","first-page":"260","DOI":"10.14245\/ns.1938358.179","article-title":"The navigated oblique lumbar interbody fusion: accuracy rate, effect on surgical time, and complications","volume":"17","author":"Xi","year":"2020","journal-title":"Neurospine"},{"issue":"11","key":"R30-20250820","doi-asserted-by":"crossref","first-page":"878","DOI":"10.1007\/s00113-008-1480-2","article-title":"Computer-aided discectomy and corpectomy in anterior reconstruction of the injured thoracolumbar spine. A prospective, controlled clinical trial","volume":"111","author":"Blattert","year":"2008","journal-title":"Der Unfallchirurg"},{"issue":"6","key":"R31-20250820","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1007\/s00586-020-06388-6","article-title":"Simultaneous single-position lateral interbody fusion and percutaneous pedicle screw fixation using O-arm-based navigation reduces the occupancy time of the operating room","volume":"29","author":"Ouchida","year":"2020","journal-title":"Eur Spine J"},{"key":"R32-20250820","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.clineuro.2018.10.013","article-title":"Simultaneous lateral interbody fusion and pedicle screws (SLIPS) with CT-guided navigation","volume":"175","author":"Sellin","year":"2018","journal-title":"Clin Neurol Neurosurg"}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000000803","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:01:17Z","timestamp":1786122077000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000000803"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,13]]},"references-count":30,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1227\/ons.0000000000000803","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,13]]},"assertion":[{"value":"2023-03-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-04-29","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}