{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T15:22:14Z","timestamp":1790436134170,"version":"4.1.0"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND AND OBJECTIVES:<\/jats:title>\n                    <jats:p>Robot-assisted pedicle screw placement is associated with greater accuracy, reduced radiation, less blood loss, shorter hospital stays, and fewer complications than freehand screw placement. However, it can be associated with longer operative times and an extended training period. We report the initial experience of a surgeon using a robot system at an academic medical center.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>We retrospectively reviewed all patients undergoing robot-assisted pedicle screw placement at a single tertiary care institution by 1 surgeon from 10\/2017 to 05\/2022. Linear regression, analysis of variance, and cumulative sum analysis were used to evaluate operative time learning curves. Operative time subanalyses for surgery indication, number of levels, and experience level were performed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      In total, 234 cases were analyzed. A significant 0.19-minute decrease in operative time per case was observed (r = 0.14,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .03). After 234 operations, this translates to a reduction in 44.5 minutes from the first to last case. A linear relationship was observed between case number and operative time in patients with spondylolisthesis (\u22120.63 minutes\/case, r = 0.41,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001), 2-level involvement (\u22120.35 minutes\/case, r = 0.19,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .05), and 4-or-more-level involvement (\u22121.29 minutes\/case, r = 0.24,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .05). This resulted in reductions in operative time ranging from 39 minutes to 1.5 hours. Continued reductions in operative time were observed across the learning, experienced, and expert phases, which had mean operative times of 214, 197, and 146 minutes, respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001). General proficiency in robot-assisted surgery was observed after the 20th case. However, 67 cases were required to reach mastery, defined as the inflection point of the cumulative sum curve.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>This study documents the long-term learning curve of a fellowship-trained spine neurosurgeon. Operative time significantly decreased with more experience. Although gaining comfort with robotic systems may be challenging or require additional training, it can benefit surgeons and patients alike with continued reductions in operative time.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1227\/ons.0000000000000862","type":"journal-article","created":{"date-parts":[[2023,8,14]],"date-time":"2023-08-14T09:01:17Z","timestamp":1692003677000},"page":"482-488","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":12,"title":["Learning Curves for Robot-Assisted Pedicle Screw Placement: Analysis of Operative Time for 234 Cases"],"prefix":"10.1227","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1144-7882","authenticated-orcid":false,"given":"Kelly","family":"Jiang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew M.","family":"Hersh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meghana","family":"Bhimreddy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carly","family":"Weber-Levine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. Daniel","family":"Davidar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arjun K.","family":"Menta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Denis","family":"Routkevitch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Safwan","family":"Alomari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brendan F.","family":"Judy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Lubelski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jon","family":"Weingart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5355-2683","authenticated-orcid":false,"given":"Nicholas","family":"Theodore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,8,14]]},"reference":[{"issue":"1","key":"R1-20250820","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/s13018-018-1046-0","article-title":"Pedicle screw loosening: the value of radiological imagings and the identification of risk factors assessed by extraction torque during screw removal surgery","volume":"14","author":"Wu","year":"2019","journal-title":"J Orthop Surg Res."},{"issue":"6","key":"R2-20250820","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1007\/s00586-002-0469-8","article-title":"Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations","volume":"11","author":"Jutte","year":"2002","journal-title":"Eur Spine J."},{"issue":"1","key":"R3-20250820","doi-asserted-by":"crossref","first-page":"e10","DOI":"10.3171\/2021.10.FOCUS21509","article-title":"Evaluating robotic pedicle screw placement against conventional modalities: a systematic review and network meta-analysis","volume":"52","author":"Naik","year":"2022","journal-title":"Neurosurg Focus."},{"issue":"2","key":"R4-20250820","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.spinee.2020.09.007","article-title":"Safety and accuracy of robot-assisted placement of pedicle screws compared to conventional free-hand technique: a systematic review and meta-analysis","volume":"21","author":"Fatima","year":"2021","journal-title":"Spine J."},{"issue":"2","key":"R5-20250820","doi-asserted-by":"crossref","first-page":"367","DOI":"10.14245\/ns.2143126.563","article-title":"Learning curve of ROSA ONE spine system for transpedicular screw placement","volume":"19","author":"Hsu","year":"2022","journal-title":"Neurospine."},{"issue":"1","key":"R6-20250820","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1093\/ons\/opy280","article-title":"Next-generation robotic spine surgery: first report on feasibility, safety, and learning curve","volume":"17","author":"Khan","year":"2019","journal-title":"Oper Neurosurg."},{"issue":"3","key":"R7-20250820","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1227\/ons.0000000000000498","article-title":"A retrospective analysis of pedicle screw placement accuracy using the ExcelsiusGPS robotic guidance system: case series","volume":"24","author":"Kanaly","year":"2023","journal-title":"Oper Neurosurg."},{"key":"R8-20250820","first-page":"35","article-title":"Retrospective study assessing the learning curve and the accuracy of minimally invasive robot-assisted pedicle screw placement during the first 41 robot-assisted spinal fusion surgeries","volume":"5","author":"Maalouly","year":"2021","journal-title":"Mini-Invasive Surg."},{"key":"R9-20250820","doi-asserted-by":"crossref","first-page":"e635","DOI":"10.1016\/j.wneu.2020.01.119","article-title":"Robot-assisted versus freehand instrumentation in short-segment lumbar fusion: experience with real-time image-guided spinal robot","volume":"136","author":"Jiang","year":"2020","journal-title":"World Neurosurg."},{"issue":"3","key":"R10-20250820","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1007\/s00464-010-1281-x","article-title":"Learning curve for robotic-assisted laparoscopic colorectal surgery","volume":"25","author":"Bokhari","year":"2011","journal-title":"Surg Endosc."},{"issue":"6","key":"R11-20250820","doi-asserted-by":"crossref","first-page":"2431","DOI":"10.21037\/jtd.2019.05.71","article-title":"Learning curve for robot-assisted lobectomy of lung cancer","volume":"11","author":"Song","year":"2019","journal-title":"J Thorac Dis."},{"issue":"7","key":"R12-20250820","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1111\/hpb.12412","article-title":"The learning curve for robotic distal pancreatectomy: an analysis of outcomes of the first 100 consecutive cases at a high-volume pancreatic centre","volume":"17","author":"Shakir","year":"2015","journal-title":"HPB."},{"issue":"1","key":"R13-20250820","doi-asserted-by":"crossref","first-page":"e3","DOI":"10.3171\/2021.10.FOCUS21496","article-title":"Learning curves in robot-assisted spine surgery: a systematic review and proposal of application to residency curricula","volume":"52","author":"Pennington","year":"2022","journal-title":"Neurosurg Focus."},{"issue":"4","key":"R14-20250820","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1007\/s00586-017-5333-y","article-title":"Robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis of randomized controlled trials","volume":"27","author":"Gao","year":"2018","journal-title":"Eur Spine J."},{"issue":"6","key":"R15-20250820","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1097\/BRS.0000000000000163","article-title":"Operative duration as an independent risk factor for postoperative complications in single-level lumbar fusion: an analysis of 4588 surgical cases","volume":"39","author":"Kim","year":"2014","journal-title":"Spine."},{"key":"R16-20250820","doi-asserted-by":"crossref","first-page":"e417","DOI":"10.1016\/j.wneu.2019.06.107","article-title":"Robot-assisted pedicle screw placement: learning curve experience","volume":"130","author":"Siddiqui","year":"2019","journal-title":"World Neurosurg."},{"key":"R17-20250820","doi-asserted-by":"crossref","first-page":"e492","DOI":"10.1016\/j.wneu.2020.07.203","article-title":"Robot-assisted percutaneous pedicle screw placement: evaluation of accuracy of the first 100 screws and comparison with cohort of fluoroscopy-guided screws","volume":"143","author":"Fayed","year":"2020","journal-title":"World Neurosurg."},{"issue":"10","key":"R18-20250820","doi-asserted-by":"crossref","first-page":"845","DOI":"10.2217\/cer-2021-0078","article-title":"Robot-assisted minimally invasive transforaminal lumbar interbody fusion versus open transforaminal lumbar interbody fusion: a retrospective matched-control analysis for clinical and quality-of-life outcomes","volume":"10","author":"Chen","year":"2021","journal-title":"J Comp Eff Res."},{"issue":"33","key":"R19-20250820","doi-asserted-by":"crossref","first-page":"10134","DOI":"10.12998\/wjcc.v9.i33.10134","article-title":"Learning curves of robot-assisted pedicle screw fixations based on the cumulative sum test","volume":"9","author":"Yu","year":"2021","journal-title":"World J Clin Cases."},{"issue":"4","key":"R20-20250820","doi-asserted-by":"crossref","first-page":"519","DOI":"10.3171\/2020.3.SPINE20208","article-title":"Three-dimensional assessment of robot-assisted pedicle screw placement accuracy and instrumentation reliability based on a preplanned trajectory","volume":"33","author":"Jiang","year":"2020","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"R21-20250820","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1186\/s41016-018-0131-x","article-title":"Pedicle screw accuracy assessment in ExcelsiusGPS\u00ae robotic spine surgery: evaluation of deviation from pre-planned trajectory","volume":"4","author":"Jiang","year":"2018","journal-title":"Chin Neurosurg J."},{"issue":"3","key":"R22-20250820","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1007\/s11701-019-00994-3","article-title":"Pedicle screw accuracy in clinical utilization of minimally invasive navigated robot-assisted spine surgery","volume":"14","author":"Vardiman","year":"2020","journal-title":"J Robot Surg."},{"issue":"1","key":"R23-20250820","doi-asserted-by":"crossref","first-page":"e2054","DOI":"10.1002\/rcs.2054","article-title":"Navigated robotic assistance improves pedicle screw accuracy in minimally invasive surgery of the lumbosacral spine: 600 pedicle screws in a single institution","volume":"16","author":"Wallace","year":"2020","journal-title":"Int J Med Robot."}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000000862","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:01:37Z","timestamp":1786122097000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000000862"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,14]]},"references-count":23,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1227\/ons.0000000000000862","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,14]]},"assertion":[{"value":"2023-03-14","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-06-07","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}