{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:52:59Z","timestamp":1786125179805,"version":"build-2736575974"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","funder":[{"DOI":"10.13039\/501100003010","name":"Ege \u00dcniversitesi","doi-asserted-by":"crossref","award":["32406"],"award-info":[{"award-number":["32406"]}],"id":[{"id":"10.13039\/501100003010","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND AND OBJECTIVES:<\/jats:title>\n                    <jats:p>Training in pedicle screw placement is crucial for neurosurgery residents, yet access to high-fidelity training models is often limited by cost and availability. This study introduces a novel, cost-effective barium-enhanced 3-dimensional (3D)\u2013printed L4-5 spine model visible under fluoroscopy, aiming to validate its effectiveness as a training tool for novice residents in pedicle screw placement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>A barium-enhanced 3D-printed L4-5 spine model was developed to simulate human bone density and provide radiopacity under fluoroscopy. Ten neurosurgery residents with no prior experience in pedicle screw placement participated in a structured training program using this model. Each resident completed three training sessions, placing four pedicle screws per session, totaling 120 screw placements. Surgical duration, screw placement accuracy, and fluoroscopy usage were recorded. Screw placement accuracy was assessed by two independent blinded evaluators using both a visual grading method and the computed tomography-based Gertzbein-Robbins classification.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      The analysis demonstrated significant improvement in surgical time across sessions (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .0001), decreasing from 20:44 \u00b1 4:32 minutes to 13:17 \u00b1 4:04 minutes. The median number of fluoroscopic images decreased from 8.5 (range: 5-18) to 6.0 (range: 5-10), although not statistically significant (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .312). Visual assessment scores improved, with median breach scores decreasing from 0.25 (0.00-3.00) to 0.00 (0.00-0.25). Similarly, the median Gertzbein-Robins grades improved from 0.50 (0.12-2.88) to 0.12 (0.00-0.62). Visual and computed tomography-based assessments showed excellent correlation (intraclass correlation coefficients = 0.978, 95% CI: 0.953-0.989,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>The barium-enhanced 3D-printed spine model ($1.61\/session) provides a highly cost-effective training tool for novice residents, demonstrating significant improvements in surgical efficiency. Although accuracy measures showed promising trends, more extensive studies may be needed to establish definitive improvements in placement precision. The model's radiopacity allows for realistic fluoroscopic imaging, bridging the gap between basic models and more expensive alternatives, which is particularly valuable in resource-limited settings.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1227\/ons.0000000000001602","type":"journal-article","created":{"date-parts":[[2025,5,7]],"date-time":"2025-05-07T09:00:47Z","timestamp":1746608447000},"page":"569-578","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Novel Barium-Enhanced 3-Dimensional-Printed Spine Model for Pedicle Screw Training: A Cost-Effective Solution and Educational Validation"],"prefix":"10.1227","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9406-4114","authenticated-orcid":false,"given":"Mustafa Serdar","family":"B\u00f6l\u00fck","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7983-5056","authenticated-orcid":false,"given":"Bilal Bahad\u0131r","family":"Akbulut","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7982-8115","authenticated-orcid":false,"given":"Ta\u015fk\u0131n","family":"Yurtseven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2306-0826","authenticated-orcid":false,"given":"H\u00fcseyin","family":"Bi\u00e7ero\u011flu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,5,7]]},"reference":[{"key":"R1-20250916","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1016\/j.wneu.2019.02.217","article-title":"Accuracy of current techniques for placement of pedicle screws in the spine: a comprehensive systematic review and meta-analysis of 51,161 screws","volume":"126","author":"Perdomo-Pantoja","year":"2019","journal-title":"World Neurosurg."},{"issue":"6","key":"R2-20250916","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1016\/j.jsurg.2010.05.007","article-title":"Operative volume in the new era: a comparison of resident operative volume before and after implementation of 80-hour work week restrictions","volume":"67","author":"Bruce","year":"2010","journal-title":"J Surg Educ."},{"issue":"12","key":"R3-20250916","doi-asserted-by":"crossref","first-page":"103267","DOI":"10.1016\/j.jsurg.2024.08.017","article-title":"Can the surgery-to-resident ratio be used to determine the ideal number of residents in a general surgery training clinic? Single center experience","volume":"81","author":"B\u00fcy\u00fckkasap","year":"2024","journal-title":"J Surg Educ."},{"issue":"5","key":"R4-20250916","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1016\/j.jsurg.2010.07.012","article-title":"Impact of the 80-hour workweek on surgical case exposure within a general surgery residency program","volume":"67","author":"Watson","year":"2010","journal-title":"J Surg Educ."},{"issue":"9","key":"R5-20250916","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1001\/jamasurg.2013.2677","article-title":"Effect of the 16-hour work limit on general surgery intern operative case volume: a multi-institutional study","volume":"148","author":"Schwartz","year":"2013","journal-title":"JAMA Surg."},{"issue":"3","key":"R6-20250916","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1002\/aet2.10103","article-title":"Clinical cadavers as a simulation resource for procedural learning","volume":"2","author":"Kovacs","year":"2018","journal-title":"AEM Educ Train."},{"key":"R8-20250916","doi-asserted-by":"crossref","first-page":"e64","DOI":"10.1016\/j.wneu.2021.07.147","article-title":"Ex vivo porcine models are valid for testing and training microsurgical lumbar decompression techniques","volume":"155","author":"S\u00e4teri","year":"2021","journal-title":"World Neurosurg."},{"issue":"11","key":"R9-20250916","first-page":"e6158","article-title":"Using porcine cadavers as an alternative to human cadavers for teaching minimally invasive spinal fusion: proof of concept and anatomical comparison","volume":"11","author":"Abbasi","year":"2019","journal-title":"Cureus"},{"key":"R10-20250916","doi-asserted-by":"crossref","first-page":"e792","DOI":"10.1016\/j.wneu.2023.12.040","article-title":"Reducing the gap in neurosurgical education in LMICs: a report of a non-profit educational program","volume":"182","author":"Menna","year":"2024","journal-title":"World Neurosurg."},{"issue":"5","key":"R11-20250916","doi-asserted-by":"crossref","first-page":"630","DOI":"10.31616\/asj.2024.0288","article-title":"Evaluating the efficacy of a cost-effective, fully three-dimensional-printed vertebra model for endoscopic spine surgery training for neurosurgical residents","volume":"18","author":"Akbulut","year":"2024","journal-title":"Asian Spine J."},{"issue":"0 1","key":"R12-20250916","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1227\/NEU.0b013e3182753093","article-title":"Role of cranial and spinal virtual and augmented reality simulation using immersive touch modules in neurosurgical training","volume":"72 Suppl 1","author":"Alaraj","year":"2013","journal-title":"Neurosurgery."},{"issue":"Suppl 1","key":"R13-20250916","doi-asserted-by":"crossref","first-page":"S85","DOI":"10.1093\/neurosurgery\/73.suppl_1.S85","article-title":"The development of a virtual simulator for training neurosurgeons to perform and perfect endoscopic endonasal transsphenoidal surgery","volume":"73","author":"Rosseau","year":"2013","journal-title":"Neurosurgery."},{"issue":"4","key":"R14-20250916","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1097\/SIH.0000000000000489","article-title":"A high-fidelity hybrid virtual reality simulator of aneurysm clipping repair with brain Sylvian fissure exploration for vascular neurosurgery training","volume":"16","author":"Teodoro-Vite","year":"2021","journal-title":"Simul Healthc."},{"issue":"3","key":"R15-20250916","doi-asserted-by":"crossref","first-page":"1719","DOI":"10.3390\/ijerph19031719","article-title":"Virtual reality in neurosurgery: beyond neurosurgical planning","volume":"19","author":"Mishra","year":"2022","journal-title":"Int J Environ Res Public Health."},{"issue":"6","key":"R16-20250916","first-page":"958","article-title":"Use of 3-dimensional modeling and virtual reality in the education of posterior spinal instrumentation","volume":"34","author":"Akgun","year":"2024","journal-title":"Turk Neurosurg."},{"issue":"9","key":"R17-20250916","doi-asserted-by":"crossref","first-page":"469","DOI":"10.3390\/bioengineering9090469","article-title":"Virtual scoliosis surgery using a 3D-printed model based on biplanar radiographs","volume":"9","author":"Courvoisier","year":"2022","journal-title":"Bioengineering."},{"key":"R18-20250916","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.wneu.2019.12.134","article-title":"Biomimetic 3-dimensional-printed posterior cervical laminectomy and fusion simulation: advancements in education tools for trainee instruction","volume":"135","author":"Clifton","year":"2020","journal-title":"World Neurosurg."},{"issue":"11","key":"R19-20250916","doi-asserted-by":"crossref","first-page":"03000605211053281","DOI":"10.1177\/03000605211053281","article-title":"Creation of a three-dimensional printed spine model for training in pain procedures","volume":"49","author":"Koh","year":"2021","journal-title":"J Int Med Res."},{"issue":"1","key":"R20-20250916","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1186\/s13018-018-0788-z","article-title":"Use of a life-size three-dimensional-printed spine model for pedicle screw instrumentation training","volume":"13","author":"Park","year":"2018","journal-title":"J Orthop Surg Res."},{"key":"R23-20250916","doi-asserted-by":"crossref","first-page":"e401","DOI":"10.1016\/j.wneu.2023.12.108","article-title":"Virtual reality-enabled resident education of lateral-access spine surgery","volume":"183","author":"Zaki","year":"2024","journal-title":"World Neurosurg."},{"issue":"5","key":"R24-20250916","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1227\/ons.0000000000001167","article-title":"Virtual reality vs phantom model: benefits and drawbacks of simulation training in neurosurgery","volume":"27","author":"Amini","year":"2024","journal-title":"Oper Neurosurg."},{"issue":"1","key":"R25-20250916","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1186\/s41205-018-0031-x","article-title":"Efficacy of using a 3D printed lumbosacral spine phantom in improving trainee proficiency and confidence in CT-guided spine procedures","volume":"4","author":"Li","year":"2018","journal-title":"3D Print Med."},{"issue":"1","key":"R26-20250916","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1007\/s00276-024-03550-3","article-title":"Applying a three-dimensional curved lumbar spine model to simulate surgery for training residents in pedicle screw insertion","volume":"47","author":"Ozturk","year":"2024","journal-title":"Surg Radiol Anat."}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000001602","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:51:24Z","timestamp":1786121484000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000001602"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,7]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1227\/ons.0000000000001602","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,7]]},"assertion":[{"value":"2024-12-06","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-15","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}