{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,21]],"date-time":"2026-11-21T04:20:02Z","timestamp":1795234802982,"version":"4.10.3"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND AND OBJECTIVES:<\/jats:title>\n                    <jats:p>Harms' technique is a widely used method for atlantoaxial stabilization. In recent years, minimally invasive surgery (MIS) using various robotic systems for percutaneous C1 to C2 screw insertion has started to be used. However, MIS raises concerns about the precision required to avoid injury to vascular and neural structures. The greater occipital nerve (GON) primarily arises from the C2 spinal root, located between the posterior arch of the C1 vertebra and the lamina of the C2 vertebra. The first bend of the GON could potentially overlay the lateral aspect of the C2 vertebra, specifically between the superior and inferior facets, ie, the interarticular part (IAP), making it susceptible to injury during C2 pedicle screw insertion causing the occipital neuralgia. That is why the aim of our study is to investigate the relationship of the GON to the axis and to assess the risk of its violation during C2 pedicle screw insertion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>Eight cadaveric specimens, embalmed in classical formaldehyde solution, were dissected to describe the position of the GON in relation to the axis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>The apex of the first GON bend was localized 3.9 \u00b1 2.2 mm from the lateral margin of the C2 IAP, 10.5 \u00b1 2.7 mm caudal from the superior facet joint of the axis. The apex of the first bend was 3.5 \u00b1 2.0 mm above the surface of the C2 IAP. The width of the C2 IAP was 14.2 \u00b1 3.8 mm while the height was 15.9 \u00b1 1.3 mm.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>The GON overlaid the cranial two-thirds of the IAP surface and can cross the entry point of the C2 screw. Therefore, we recommend using the most caudal entry point as possible, with steeper cranial angle controlled with navigation, to avoid the GON injury during MIS.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1227\/ons.0000000000001697","type":"journal-article","created":{"date-parts":[[2025,7,3]],"date-time":"2025-07-03T09:01:17Z","timestamp":1751533277000},"page":"755-759","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Anatomic Relationship Between the Greater Occipital Nerve and the Axis: Is It Possible to Safely Insert a Percutaneous C2 Screw Without Causing Occipital Neuralgia?"],"prefix":"10.1227","volume":"30","author":[{"given":"Anhelina","family":"Khadanovich","sequence":"first","affiliation":[{"name":"Department of Anatomy, Second Faculty of Medicine, Charles University, Prague, Czech Republic;"},{"name":"Center for Endoscopic, Surgical and Clinical Anatomy (CESKA), Second Faculty of Medicine, Charles University, Prague, Czech Republic;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michal","family":"Benes","sequence":"additional","affiliation":[{"name":"Department of Anatomy, Second Faculty of Medicine, Charles University, Prague, Czech Republic;"},{"name":"Center for Endoscopic, Surgical and Clinical Anatomy (CESKA), Second Faculty of Medicine, Charles University, Prague, Czech Republic;"},{"name":"1st Department of Orthopaedics, First Faculty of Medicine, Charles University and Motol University Hospital, Prague, Czech Republic;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5985-9595","authenticated-orcid":false,"given":"Radek","family":"Kaiser","sequence":"additional","affiliation":[{"name":"Department of Anatomy, Second Faculty of Medicine, Charles University, Prague, Czech Republic;"},{"name":"Center for Endoscopic, Surgical and Clinical Anatomy (CESKA), Second Faculty of Medicine, Charles University, Prague, Czech Republic;"},{"name":"Department of Spinal Surgery, Oxford University Hospitals NHS Foundation Trust, Oxford, UK;"},{"name":"Nuffield Department of Clinical Neuroscience, University of Oxford, Oxford, UK;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeremy","family":"Reynolds","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, Oxford University Hospitals NHS Foundation Trust, Oxford, UK;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerard","family":"Mawhinney","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, Oxford University Hospitals NHS Foundation Trust, Oxford, UK;"},{"name":"Nuffield Department of Clinical Neuroscience, University of Oxford, Oxford, UK;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Stulik","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, First Faculty of Medicine, Charles University, University Hospital Motol, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Kachlik","sequence":"additional","affiliation":[{"name":"Department of Anatomy, Second Faculty of Medicine, Charles University, Prague, Czech Republic;"},{"name":"Center for Endoscopic, Surgical and Clinical Anatomy (CESKA), Second Faculty of Medicine, Charles University, Prague, Czech Republic;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,7,3]]},"reference":[{"issue":"22","key":"R1-20260415","doi-asserted-by":"crossref","first-page":"2467","DOI":"10.1097\/00007632-200111150-00014","article-title":"Posterior C1-C2 fusion with polyaxial screw and rod fixation","volume":"26","author":"Harms","year":"2001","journal-title":"Spine."},{"issue":"4","key":"R2-20260415","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1007\/s00586-006-0241-6","article-title":"Atlantoaxial fixation using the polyaxial screw-rod system","volume":"16","author":"Stulik","year":"2007","journal-title":"Eur Spine J."},{"issue":"3","key":"R3-20260415","doi-asserted-by":"crossref","first-page":"439","DOI":"10.21037\/jss-20-676","article-title":"MAZOR-X robotic-navigated percutaneous C2 screw placement for hangman\u2019s fracture: a case report","volume":"7","author":"Asuzu","year":"2021","journal-title":"J Spine Surg."},{"issue":"6","key":"R4-20260415","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1093\/ons\/opaa208","article-title":"Cirq\u00ae robotic assistance for minimally invasive C1-C2 posterior instrumentation: report on feasibility and safety","volume":"19","author":"Farah","year":"2020","journal-title":"Oper Neurosurg."},{"key":"R5-20260415","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1007\/978-3-319-01065-6_8","article-title":"Minimally invasive posterior trans-muscular C1\u2013C2 screw fixation through an anatomical corridor to preserve occipitocervical tension band: surgical anatomy and clinical experience","volume":"40","author":"D\u00edaz","year":"2014","journal-title":"Adv Tech Stand Neurosurg."},{"issue":"1","key":"R6-20260415","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1186\/s12893-022-01826-2","article-title":"Posterior atlantoaxial internal fixation using Harms technique assisted by 3D-based navigation robot for treatment of atlantoaxial instability","volume":"22","author":"Lang","year":"2022","journal-title":"BMC Surg."},{"issue":"7","key":"R7-20260415","first-page":"786","article-title":"Improved accuracy of cervical spinal surgery with robot-assisted screw insertion: a prospective, randomized, controlled study","volume":"13","author":"Fan","year":"2020","journal-title":"Spine J."},{"key":"R8-20260415","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.wneu.2017.07.159","article-title":"Modified posterior C1 lateral mass screw insertion for type II odontoid process fractures using intraoperative computed tomography-based spinal navigation to minimize postoperative occipital neuralgia","volume":"107","author":"Ishak","year":"2017","journal-title":"World Neurosurg."},{"issue":"3","key":"R9-20260415","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1007\/s10143-017-0923-z","article-title":"Postoperative occipital neuralgia in posterior upper cervical spine surgery: a systematic review","volume":"41","author":"Guan","year":"2018","journal-title":"Neurosurg Rev."},{"issue":"10","key":"R10-20260415","first-page":"e18584","article-title":"Ultrasound-guided occipital nerve block for treatment of atypical occipital neuralgia","volume":"13","author":"Skinner","year":"2021","journal-title":"Cureus."},{"issue":"1","key":"R11-20260415","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.neurad.2017.09.001","article-title":"Greater occipital nerve MR tractography: feasibility and anatomical considerations","volume":"45","author":"Kastler","year":"2018","journal-title":"J Neuroradiol."},{"issue":"8","key":"R12-20260415","doi-asserted-by":"crossref","first-page":"2512","DOI":"10.1007\/s00330-015-3622-6","article-title":"A simplified CT-guided approach for greater occipital nerve infiltration in the management of occipital neuralgia","volume":"25","author":"Kastler","year":"2015","journal-title":"Eur Radiol."},{"issue":"3","key":"R13-20260415","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1007\/s00234-008-0480-9","article-title":"Evaluation of the effectiveness of CT-guided infiltration in the treatment of Arnold\u2019s neuralgia","volume":"51","author":"Aubry","year":"2009","journal-title":"Neuroradiology."},{"issue":"2","key":"R14-20260415","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1007\/s00234-023-03273-z","article-title":"Review of craniofacial pain syndromes involving the greater occipital nerve: relevant anatomy, clinical findings, and interventional management","volume":"66","author":"Fabry","year":"2024","journal-title":"Neuroradiology."},{"issue":"Suppl 1","key":"R15-20260415","first-page":"9","article-title":"The International Classification of Headache Disorders: 2nd edition","volume":"24","year":"2004","journal-title":"Cephalalgia."},{"issue":"7","key":"R16-20260415","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1016\/j.spinee.2013.04.006","article-title":"Postoperative occipital neuralgia with and without C2 nerve root transection during atlantoaxial screw fixation: a post-hoc comparative outcome study of prospectively collected data","volume":"13","author":"Yeom","year":"2013","journal-title":"Spine J."},{"issue":"18","key":"R17-20260415","doi-asserted-by":"crossref","first-page":"e1067","DOI":"10.1097\/BRS.0000000000002069","article-title":"Does transection of the C2 nerve roots during C1 lateral mass screw placement for atlantoaxial fixation result in a superior outcome? A systematic review of the literature and meta-analysis","volume":"42","author":"Badhiwala","year":"2017","journal-title":"Spine."},{"issue":"2","key":"R18-20260415","doi-asserted-by":"crossref","first-page":"111","DOI":"10.3340\/jkns.2008.43.2.111","article-title":"Troublesome occipital neuralgia developed by C1-C2 Harms construct","volume":"43","author":"Rhee","year":"2008","journal-title":"J Korean Neurosurg Soc."},{"issue":"3","key":"R19-20260415","first-page":"e1074","article-title":"C2 and greater occipital nerve: the anatomic and functional implications in spinal surgery","volume":"9","author":"Janjua","year":"2017","journal-title":"Cureus."},{"issue":"2","key":"R20-20260415","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1007\/s00586-018-5793-8","article-title":"Anatomy of the dens and its implications for fracture treatment: an anatomical and radiological study","volume":"28","author":"\u0160tul\u00edk","year":"2019","journal-title":"Eur Spine J."},{"key":"R21-20260415","doi-asserted-by":"crossref","first-page":"155","DOI":"10.4103\/2152-7806.143743","article-title":"The intramuscular course of the greater occipital nerve: novel findings with potential implications for operative interventions and occipital neuralgia","volume":"5","author":"Tubbs","year":"2014","journal-title":"Surg Neurol Int."},{"issue":"4","key":"R22-20260415","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1007\/s00276-022-02906-x","article-title":"Anatomy of the greater occipital nerve: implications in posterior fossa approaches","volume":"44","author":"Lain\u00e9","year":"2022","journal-title":"Surg Radiol Anat."},{"issue":"8","key":"R25-20260415","doi-asserted-by":"crossref","first-page":"1374","DOI":"10.1016\/j.spinee.2017.12.003","article-title":"Safety and accuracy of freehand versus navigated C2 pars or pedicle screw placement","volume":"18","author":"Hlubek","year":"2018","journal-title":"Spine J."},{"issue":"6","key":"R26-20260415","doi-asserted-by":"crossref","first-page":"351","DOI":"10.3340\/jkns.2011.49.6.351","article-title":"Targeting a safe entry point for C2 pedicle screw fixation in patients with atlantoaxial instability","volume":"49","author":"Chun","year":"2011","journal-title":"J Korean Neurosurg Soc."},{"issue":"7","key":"R27-20260415","doi-asserted-by":"crossref","first-page":"1992","DOI":"10.1177\/21925682211068410","article-title":"Anatomical and technical considerations of robot-assisted cervical pedicle screw placement: a cadaveric study","volume":"13","author":"Mao","year":"2023","journal-title":"Glob Spine J."},{"issue":"3","key":"R29-20260415","doi-asserted-by":"crossref","first-page":"168","DOI":"10.4184\/asj.2012.6.3.168","article-title":"Computer-assisted C1-C2 transarticular screw fixation \u201cMagerl technique\u201d for atlantoaxial instability","volume":"6","author":"Uehara","year":"2012","journal-title":"Asian Spine J."}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000001697","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:40:03Z","timestamp":1786120803000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000001697"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,3]]},"references-count":26,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1227\/ons.0000000000001697","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,3]]},"assertion":[{"value":"2025-02-15","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-04-17","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}