{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T16:57:50Z","timestamp":1791046670037,"version":"4.1.0"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND AND OBJECTIVES:<\/jats:title>\n                    <jats:p>Spinal cord stimulation (SCS) is a widespread tool used to treat chronic pain. There are 2 primary methods for permanent implantation of SCS: electrode lead placement through percutaneous needle or paddle electrodes by open laminotomy. The goal of this report was to use a tubular, minimally invasive method to implant SCS paddles, describe the feasibility and safety of the method, and provide a companion video illustration of the technique.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>One-hundred two minimally invasive spinal cord stimulator paddle electrode procedures were performed on 76 men and 26 women. We completed a retrospective review of the placement, replacement, and removal of spinal cord stimulator paddle electrodes in this single-surgeon cohort of patients to assess the procedure's feasibility and any technical issues encountered.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>There were 86 primary system placements; 11 paddle electrode replacement procedures for lead fractures, lead migration, or revision of the entire system; and 5 procedures for the complete removal of spinal cord stimulator systems without replacement. There were no neurological deficits or epidural hematomas. There was 1 single infection of the device requiring removal and eventual replacement (0.98%), etiology assessed to be likely secondary to dental abscess, not the SCS procedure itself.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>We describe a minimally invasive tubular access mediated method, whereby paddle electrodes can be placed successfully with minimal morbidity. We describe any technical issues, provide an accompanying narrated video of an illustrative case, and describe techniques for dealing with paddle migration including the removal of a paddle lead using tubular access.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1227\/ons.0000000000001801","type":"journal-article","created":{"date-parts":[[2025,10,15]],"date-time":"2025-10-15T15:20:13Z","timestamp":1760541613000},"page":"264-269","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Minimally Invasive Spinal Cord Stimulator Paddle Electrode Placement: Technique and Complications in a Single Surgeon Cohort"],"prefix":"10.1227","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0264-7348","authenticated-orcid":false,"given":"Peter G.","family":"Cruz-Gordillo","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Oregon Health Sciences University, Portland, Oregon, USA;"},{"name":"Division of Neurosurgery, Operative Care Division, Portland Veterans Affairs Medical Center, Portland, Oregon, USA"},{"name":"Current Affiliation: Department of Neurosurgery, Oregon Health Sciences University and the Operative Care Division, Section of Neurosurgery at the Portland Veterans Affairs Medical Center, Portland, Oregon, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonia L.","family":"Gragg","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Oregon Health Sciences University, Portland, Oregon, USA;"},{"name":"Current Affiliation: Department of Neurology, Oregon Health Sciences University, Portland, Oregon, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Donald A.","family":"Ross","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Oregon Health Sciences University, Portland, Oregon, USA;"},{"name":"Division of Neurosurgery, Operative Care Division, Portland Veterans Affairs Medical Center, Portland, Oregon, USA"},{"name":"Current Affiliation: Department of Neurosurgery, Oregon Health Sciences University and the Operative Care Division, Section of Neurosurgery at the Portland Veterans Affairs Medical Center, Portland, Oregon, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,10,15]]},"reference":[{"issue":"10053","key":"R1-20260720","doi-asserted-by":"crossref","first-page":"1545","DOI":"10.1016\/S0140-6736(16)31678-6","article-title":"Global, regional, and national incidence, prevalence, and years lived with disability for 310 diseases and injuries, 1990-2015: a systematic analysis for the Global Burden of Disease Study 2015","volume":"388","year":"2016","journal-title":"Lancet."},{"issue":"24","key":"R2-20260720","doi-asserted-by":"crossref","first-page":"E1443","DOI":"10.1097\/BRS.0000000000003174","article-title":"Personal and societal impact of low back pain. The Groningen spine cohort","volume":"44","author":"Dutmer","year":"2019","journal-title":"Spine."},{"issue":"4","key":"R3-20260720","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1227\/ons.0000000000000995","article-title":"The evolution of surgical technique in spinal cord stimulation: a scoping review","volume":"26","author":"Bean","year":"2024","journal-title":"Oper Neurosurg."},{"issue":"9","key":"R4-20260720","doi-asserted-by":"crossref","first-page":"E401","DOI":"10.5435\/JAAOS-D-17-00829","article-title":"The use of spinal cord stimulation\/neuromodulation in the management of chronic pain","volume":"27","author":"Schmidt","year":"2019","journal-title":"J Am Acad Orthop Surg."},{"issue":"6","key":"R5-20260720","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1055\/s-0034-1371517","article-title":"Paddle versus cylindrical leads for percutaneous implantation in spinal cord stimulation for failed back surgery syndrome: a single-center trial","volume":"75","author":"Kinfe","year":"2014","journal-title":"J Neurol Surg A Cent Eur Neurosurg."},{"issue":"2","key":"R6-20260720","first-page":"381","article-title":"Spinal cord stimulation electrode design: prospective, randomized, controlled trial comparing percutaneous and laminectomy electrodes: part I-technical outcomes","volume":"51","author":"North","year":"2002","journal-title":"Neurosurgery."},{"issue":"5","key":"R7-20260720","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1227\/01.NEU.0000180030.00167.b9","article-title":"Spinal cord stimulation electrode design: a prospective, randomized, controlled trial comparing percutaneous with laminectomy electrodes: part II-clinical outcomes","volume":"57","author":"North","year":"2005","journal-title":"Neurosurgery."},{"issue":"pt 1","key":"R8-20260720","first-page":"105","article-title":"Minimally invasive placement of epidural plate electrodes under local anaesthesia in spinal cord stimulation","volume":"97","author":"Beems","year":"2007","journal-title":"Acta Neurochir Suppl."},{"issue":"2","key":"R9-20260720","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1111\/j.1533-2500.2010.00407.x","article-title":"Retrospective review of 707 cases of spinal cord stimulation: indications and complications","volume":"11","author":"Mekhail","year":"2011","journal-title":"Pain Pract."},{"issue":"2","key":"R10-20260720","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1097\/00006123-200002000-00025","article-title":"Laminectomy versus percutaneous electrode placement for spinal cord stimulation","volume":"46","author":"Villavicencio","year":"2000","journal-title":"Neurosurgery."},{"issue":"1","key":"R11-20260720","doi-asserted-by":"crossref","first-page":"45","DOI":"10.36076\/ppj.2011\/14\/45","article-title":"Alternative approach to needle placement in spinal cord stimulator trial\/implantation","volume":"14","author":"Zhu","year":"2011","journal-title":"Pain Physician."},{"issue":"2","key":"R12-20260720","doi-asserted-by":"crossref","first-page":"195","DOI":"10.36076\/ppj.2011\/14\/195","article-title":"Alternative approach to needle placement in cervical spinal cord stimulator insertion","volume":"14","author":"Zhu","year":"2011","journal-title":"Pain Physician."},{"issue":"3","key":"R13-20260720","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1227\/NEU.0b013e318236a57c","article-title":"Back pain: a real target for spinal cord stimulation?","volume":"70","author":"Rigoard","year":"2012","journal-title":"Neurosurgery."},{"issue":"5","key":"R14-20260720","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1111\/papr.12644","article-title":"Utilization of leads after permanent implant in spinal cord stimulator systems","volume":"18","author":"Sanders","year":"2018","journal-title":"Pain Pract."},{"issue":"4","key":"R15-20260720","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1111\/j.1525-1403.2011.00372.x","article-title":"Long-term outcomes of spinal cord stimulation with paddle leads in the treatment of complex regional pain syndrome and failed back surgery syndrome","volume":"14","author":"Sears","year":"2011","journal-title":"Neuromodulation."},{"issue":"4","key":"R16-20260720","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1111\/j.1525-1403.2011.00368.x","article-title":"Percutaneously implanted plates in failed back surgery syndrome (FBSS)","volume":"14","author":"Vonh\u00f6gen","year":"2011","journal-title":"Neuromodulation."},{"issue":"8","key":"R17-20260720","doi-asserted-by":"crossref","first-page":"138","DOI":"10.3390\/brainsci8080138","article-title":"Spinal cord stimulation for neuropathic pain: current trends and future applications","volume":"8","author":"Dones","year":"2018","journal-title":"Brain Sci."},{"key":"R18-20260720","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.cobme.2018.10.005","article-title":"Innovations in spinal cord stimulation for pain","volume":"8","author":"Lempka","year":"2018","journal-title":"Curr Opin Biomed Eng"},{"issue":"1","key":"R19-20260720","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1227\/NEU.0b013e31824e5114","article-title":"The utility of bone cement to prevent lead migration with minimally invasive placement of spinal cord stimulator laminectomy leads","volume":"71","author":"Connor","year":"2012","journal-title":"Neurosurgery."},{"issue":"5","key":"R20-20260720","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1097\/BRS.0000000000002050","article-title":"Minimally invasive placement of spinal cord stimulator paddle electrodes is associated with improved perioperative and long-term experience among neuropathic pain patients","volume":"43","author":"Shamji","year":"2018","journal-title":"Spine."},{"key":"R21-20260720","doi-asserted-by":"crossref","first-page":"201053","DOI":"10.1100\/2012\/201053","article-title":"Spinal anesthesia and minimal invasive laminotomy for paddle electrode placement in spinal cord stimulation: technical report and clinical results at long-term followup","volume":"2012","author":"Sarubbo","year":"2012","journal-title":"Scientific World J"},{"issue":"3","key":"R22-20260720","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1227\/NEU.0000000000000008","article-title":"Multicolumn spinal cord stimulation lead implantation using an optic transligamentar minimally invasive technique","volume":"73","author":"Rigoard","year":"2013","journal-title":"Neurosurgery."},{"key":"R23-20260720","first-page":"451637","article-title":"Complications of minimally invasive, tubular access surgery for cervical, thoracic, and lumbar surgery","volume":"2014","author":"Ross","year":"2014","journal-title":"Minim Invasive Surg."},{"issue":"1","key":"R24-20260720","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1093\/neuros\/nyy062","article-title":"Nonawake vs awake placement of spinal cord stimulators: a prospective, multicenter study comparing safety and efficacy","volume":"84","author":"Falowski","year":"2019","journal-title":"Neurosurgery."},{"issue":"2","key":"R25-20260720","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1111\/ner.12843","article-title":"Spinal cord stimulation infection rate and risk factors: results from a United States payer database","volume":"22","author":"Falowski","year":"2019","journal-title":"Neuromodulation."},{"issue":"1","key":"R26-20260720","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1111\/papr.13145","article-title":"Preoperative hemoglobin A1c and perioperative blood glucose in patients with diabetes mellitus undergoing spinal cord stimulation surgery: a literature review of surgical site infection risk","volume":"23","author":"Hagedorn","year":"2023","journal-title":"Pain Pract."},{"issue":"2","key":"R27-20260720","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1016\/j.neurom.2024.10.007","article-title":"Cylindrical vs paddle leads in spinal cord stimulation for the long-term treatment of chronic pain: a systematic review and meta-analysis","volume":"28","author":"El Hadwe","year":"2025","journal-title":"Neuromodulation."},{"key":"R28-20260720","first-page":"CD014789","article-title":"Spinal cord stimulation for low back pain","volume":"7","author":"Trager","year":"2023","journal-title":"Cochrane Database Syst Rev."}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000001801","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:01:04Z","timestamp":1786122064000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000001801"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,15]]},"references-count":28,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1227\/ons.0000000000001801","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,15]]},"assertion":[{"value":"2025-03-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-08-18","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}