{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T17:44:58Z","timestamp":1792259098823,"version":"4.4.0"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,11]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND AND OBJECTIVES:<\/jats:title>\n                    <jats:p>To investigate the effects of adjacent-segment biomechanics at the cervicothoracic junction using different fixation constructs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>Six human cadaveric spine specimens (C5-T4) were analyzed for range of motion (ROM) in the intact condition. All specimens were destabilized and reconstructed using 4.0-mm pedicle screws at T1-T3. Two constructs included interlaminar hooks at C6 and C7 with 3.5- or 4.0-mm rods (C6-T3). Two constructs included lateral mass screws at C6 and pedicle screws at C7, with 3.5- or 4.0-mm rods (C6-T3). Two screw-connector-rod constructs included lateral mass screws at C6 and pedicle screws at C7, with 3.5- or 4.0-mm rods; 1 rod spanned C6-C7 with a connector to a second rod of the same size spanning T1-T3. ROMs at upper and lower adjacent levels were compared with the intact condition.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Upper adjacent ROMs for C6-T3 screw-rod fixation with either rod size did not differ from the intact condition in any direction (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; .78). Screw-connector-rod fixation ROM with either rod size did not differ from the intact condition in any direction (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; .07). ROMs for upper adjacent hook-rod constructs were significantly less for both rod sizes than that of the intact condition in all directions (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .006). The lower adjacent constructs did not differ with either rod size from the intact condition (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; .3).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>The adjacent-segment motion magnitude was dictated by construct composition at the cervicothoracic junction. Although screw constructs provided an adjacent-level ROM most like that of the intact condition, hook constructs provided a smooth transition by limiting adjacent-segment ROM.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1227\/ons.0000000000001880","type":"journal-article","created":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T14:01:04Z","timestamp":1767016864000},"page":"812-818","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Cervicothoracic Segment Fusion and Its Effects on Adjacent-Level Range of Motion: A Biomechanical Study Comparing Interlaminar Hooks, Lateral Mass Screws, and Side Connectors"],"prefix":"10.1227","volume":"31","author":[{"given":"Temesgen G.","family":"Assefa","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA;"},{"name":"Current affiliation: Barrow Global, Franke Neuroscience Education Center, Phoenix, Arizona, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luke A.","family":"Mugge","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna G. U.","family":"Sawa","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph D.","family":"DiDomenico","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S. Harrison","family":"Farber","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexis C.","family":"Ratliff","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neil R.","family":"Crawford","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan S.","family":"Uribe","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian P.","family":"Kelly","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6867-3568","authenticated-orcid":false,"given":"Jay D.","family":"Turner","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,12,29]]},"reference":[{"issue":"16","key":"R1-20261017","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1097\/00007632-199508150-00007","article-title":"Instrumentation of the cervicothoracic junction after destabilization","volume":"20","author":"Bueff","year":"1995","journal-title":"Spine (Phila Pa 1976)"},{"issue":"4","key":"R2-20261017","doi-asserted-by":"crossref","first-page":"552","DOI":"10.3171\/jns.1996.84.4.0552","article-title":"Posterior instrumentation of the unstable cervicothoracic spine","volume":"84","author":"Chapman","year":"1996","journal-title":"J Neurosurg"},{"issue":"6","key":"R3-20261017","first-page":"323","article-title":"Managing disorders of the cervicothoracic junction","volume":"31","author":"Daffner","year":"2002","journal-title":"Am J Orthop (Belle Mead NJ)"},{"issue":"5","key":"R4-20261017","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1016\/j.spinee.2005.12.010","article-title":"Neurological and functional outcome after unstable cervicothoracic junction injury treated by posterior reduction and synthesis","volume":"6","author":"Lenoir","year":"2006","journal-title":"Spine J"},{"issue":"11","key":"R5-20261017","doi-asserted-by":"crossref","first-page":"1246","DOI":"10.1097\/00007632-200406010-00015","article-title":"Posterior cervicothoracic instrumentation in spine tumors","volume":"29","author":"Mazel","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"R6-20261017","doi-asserted-by":"crossref","first-page":"111","DOI":"10.3171\/SPI\/2008\/9\/8\/111","article-title":"Posterior stabilization strategies following resection of cervicothoracic junction tumors: review of 90 consecutive cases","volume":"9","author":"Placantonakis","year":"2008","journal-title":"J Neurosurg Spine"},{"issue":"4","key":"R7-20261017","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1007\/s005860050174","article-title":"Operative treatment of unstable injuries of the cervicothoracic junction","volume":"8","author":"Sapkas","year":"1999","journal-title":"Eur Spine J"},{"issue":"4","key":"R8-20261017","doi-asserted-by":"crossref","first-page":"278","DOI":"10.3171\/spi.2006.4.4.278","article-title":"Regional instability following cervicothoracic junction surgery","volume":"4","author":"Steinmetz","year":"2006","journal-title":"J Neurosurg Spine"},{"issue":"13","key":"R9-20261017","doi-asserted-by":"crossref","first-page":"1505","DOI":"10.1097\/01.brs.0000167824.19875.e9","article-title":"Biomechanics of stabilization after cervicothoracic compression-flexion injury","volume":"30","author":"Ames","year":"2005","journal-title":"Spine (Phila Pa 1976)"},{"issue":"7","key":"R10-20261017","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1097\/00007632-199904010-00008","article-title":"Pedicle and transverse process screws of the upper thoracic spine. Biomechanical comparison of loads to failure","volume":"24","author":"Heller","year":"1999","journal-title":"Spine (Phila Pa 1976)"},{"issue":"24","key":"R11-20261017","doi-asserted-by":"crossref","first-page":"2763","DOI":"10.1097\/00007632-200212150-00005","article-title":"Posterior stabilization at the cervicothoracic junction: a biomechanical study","volume":"27","author":"Kreshak","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"issue":"17","key":"R12-20261017","doi-asserted-by":"crossref","first-page":"1948","DOI":"10.1097\/00007632-199709010-00002","article-title":"Biomechanical evaluation of posterior cervical stabilization after a wide laminectomy","volume":"22","author":"Grubb","year":"1997","journal-title":"Spine (Phila Pa 1976)"},{"issue":"22","key":"R13-20261017","doi-asserted-by":"crossref","first-page":"2529","DOI":"10.1097\/00007632-199411001-00007","article-title":"Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine","volume":"19","author":"Kotani","year":"1994","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"R14-20261017","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.spinee.2006.04.015","article-title":"Biomechanical comparison of two-level cervical locking posterior screw\/rod and hook\/rod techniques","volume":"7","author":"Espinoza-Larios","year":"2007","journal-title":"Spine J"},{"issue":"5","key":"R15-20261017","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1016\/j.spinee.2021.01.011","article-title":"Instrumentation techniques to prevent proximal junctional kyphosis and proximal junctional failure in adult spinal deformity correction-a systematic review of biomechanical studies","volume":"21","author":"Doodkorte","year":"2021","journal-title":"Spine J"},{"issue":"9","key":"R16-20261017","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1007\/s43390-020-00278-z","article-title":"State of the art: proximal junctional kyphosis-diagnosis, management and prevention","volume":"3","author":"Sardar","year":"2021","journal-title":"Spine Deform"},{"issue":"16","key":"R17-20261017","doi-asserted-by":"crossref","first-page":"e964","DOI":"10.1097\/BRS.0000000000001523","article-title":"Economic impact of revision surgery for proximal junctional failure after adult spinal deformity surgery: a cost analysis of 57 operations in a 10-year experience at a major deformity center","volume":"41","author":"Theologis","year":"2016","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"R18-20261017","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.nec.2013.01.001","article-title":"Proximal junctional kyphosis and proximal junctional failure","volume":"24","author":"Hart","year":"2013","journal-title":"Neurosurg Clin N Am"},{"key":"R19-20261017","doi-asserted-by":"crossref","first-page":"e139","DOI":"10.1016\/j.wneu.2018.12.040","article-title":"Biomechanical evaluation of cervicothoracic junction fusion constructs","volume":"124","author":"Godzik","year":"2019","journal-title":"World Neurosurg"},{"issue":"19","key":"R20-20261017","doi-asserted-by":"crossref","first-page":"2097","DOI":"10.1097\/00007632-199510000-00005","article-title":"An apparatus for applying pure nonconstraining moments to spine segments in vitro","volume":"20","author":"Crawford","year":"1995","journal-title":"Spine (Phila Pa 1976)"},{"issue":"8","key":"R21-20261017","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1097\/BRS.0b013e318279a95e","article-title":"Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support","volume":"38","author":"Perez-Orribo","year":"2013","journal-title":"Spine (Phila Pa 1976)"},{"issue":"10","key":"R22-20261017","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1097\/00007632-198810000-00013","article-title":"Biomechanical evaluation of spinal fixation devices: I. A conceptual framework","volume":"13","author":"Panjabi","year":"1988","journal-title":"Spine (Phila Pa 1976)"},{"issue":"10","key":"R23-20261017","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1097\/00007632-198810000-00014","article-title":"Biomechanical evaluation of spinal fixation devices: II. Stability provided by eight internal fixation devices","volume":"13","author":"Panjabi","year":"1988","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"R24-20261017","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.spinee.2017.10.065","article-title":"Comparison of three-dimensional helical axes of the cervical spine between in vitro and in vivo testing","volume":"18","author":"Jonas","year":"2018","journal-title":"Spine J"},{"issue":"9","key":"R25-20261017","first-page":"223","article-title":"Bilateral posterior cervical cages provide biomechanical stability: assessment of stand-alone and supplemental fixation for anterior cervical discectomy and fusion","volume":"9","author":"Voronov","year":"2016","journal-title":"Med Devices (Auckl)"},{"issue":"5","key":"R26-20261017","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1097\/00007632-199703010-00020","article-title":"Construction of local vertebral coordinate systems using a digitizing probe. Technical note","volume":"22","author":"Crawford","year":"1997","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"R27-20261017","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/S0268-0033(98)00080-1","article-title":"A new technique for determining 3-D joint angles: the tilt\/twist method","volume":"14","author":"Crawford","year":"1999","journal-title":"Clin Biomech (Bristol)"},{"issue":"2","key":"R28-20261017","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1016\/j.nec.2007.02.012","article-title":"The cervicothoracic junction","volume":"18","author":"Wang","year":"2007","journal-title":"Neurosurg Clin N Am"},{"issue":"6","key":"R29-20261017","doi-asserted-by":"crossref","first-page":"e188","DOI":"10.1097\/01.brs.0000257577.70576.07","article-title":"Stabilizing potential of anterior, posterior, and circumferential fixation for multilevel cervical arthrodesis: an in vitro human cadaveric study of the operative and adjacent segment kinematics","volume":"32","author":"Dmitriev","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"issue":"5","key":"R30-20261017","doi-asserted-by":"crossref","first-page":"622","DOI":"10.3171\/2010.5.SPINE09848","article-title":"Biomechanical comparison of posterior cervicothoracic instrumentation techniques after one-level laminectomy and facetectomy","volume":"13","author":"Eleraky","year":"2010","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"R31-20261017","doi-asserted-by":"crossref","first-page":"15","DOI":"10.3171\/2019.7.SPINE19279","article-title":"Analysis of adjacent-segment cervical kinematics: the role of construct length and the dorsal ligamentous complex","volume":"32","author":"Lubelski","year":"2020","journal-title":"J Neurosurg Spine"},{"issue":"4","key":"R32-20261017","doi-asserted-by":"crossref","first-page":"435","DOI":"10.3171\/2010.4.SPINE09995","article-title":"The effect of spinal instrumentation on kinematics at the cervicothoracic junction: emphasis on soft tissue response using an in-vitro human cadaveric model","volume":"13","author":"Kretzer","year":"2010","journal-title":"J Neurosurg Spine"},{"issue":"13","key":"R33-20261017","doi-asserted-by":"crossref","first-page":"e778","DOI":"10.1097\/BRS.0b013e31824780b8","article-title":"Adjacent-level range of motion and intradiscal pressure after posterior cervical decompression and fixation: an in vitro human cadaveric model","volume":"37","author":"Kretzer","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"issue":"5","key":"R34-20261017","doi-asserted-by":"crossref","first-page":"749","DOI":"10.3171\/2022.4.SPINE22202","article-title":"Effects of rod diameter on kinematics of posterior cervical spine instrumented constructs: an ex vivo study","volume":"37","author":"Kiapour","year":"2022","journal-title":"J Neurosurg Spine"}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000001880","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T17:00:36Z","timestamp":1792256436000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000001880"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,29]]},"references-count":34,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1227\/ons.0000000000001880","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,29]]},"assertion":[{"value":"2025-04-28","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-11","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}