{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:49:56Z","timestamp":1792788596771,"version":"4.5.0"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","funder":[{"name":"Medtronic","award":["ERP-2023-13397"],"award-info":[{"award-number":["ERP-2023-13397"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,11]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND AND OBJECTIVES:<\/jats:title>\n                    <jats:p>To assess differences in biomechanical stability provided by posterior or transforaminal lumbar interbody instrumentation with expandable relative to static implants and unilateral or bilateral implants.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>Nine human cadaveric lumbosacral spine specimens were subjected to motion testing before instrumentation and after single-level posterior decompression and interbody instrumentation at L3-4 with randomized order of single and bilateral static and expandable interbody implants. Measurements of disk height were also performed on the intact spine and with different implant paradigms. Changes in motion at each lumbar segment, comparison of implant paradigms, and changes in disk height at the instrumented level were statistically compared using linear mixed-effects models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>Instrumentation resulted in a significant reduction in flexion, extension, axial rotation, and lateral bending at L3-4 for all interbody implant paradigms. Bilateral expandable cages resulted in a significantly greater reduction in lateral bending relative to single static implants and neared significance compared with bilateral static and unilateral expandable implants. Disk height increased with all implants, and bilateral expandable cages significantly increased height relative to unilateral and bilateral static cages.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Bilateral expandable implants confer greater stability with regard to lateral bending forces compared with unilateral expandable, unilateral static, and bilateral static cages with posterior interbody instrumentation. In addition, bilateral expandable implants confer greater ability to increase disk space height compared with static cages. Therefore, the added cost of bilateral expandable cages may be warranted in the setting of significant coronal imbalance or very collapsed disk spaces.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1227\/ons.0000000000001884","type":"journal-article","created":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T14:00:42Z","timestamp":1767016842000},"page":"828-835","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Biomechanical Comparison of Transforaminal Interbody Fusion Implants: Static vs Expandable Cages and Unilateral Versus Bilateral Cages"],"prefix":"10.1227","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7597-9466","authenticated-orcid":false,"given":"Clayton L.","family":"Rosinski","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, The University of Iowa, Iowa City, Iowa, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicole A. D.","family":"Watson","sequence":"additional","affiliation":[{"name":"Department of Orthopedics and Rehabilitation, The University of Iowa, Iowa City, Iowa, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael E.","family":"Kritikos","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, The University of Iowa, Iowa City, Iowa, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kirill V.","family":"Nourski","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, The University of Iowa, Iowa City, Iowa, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony J.","family":"Marincovich","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, The University of Iowa, Iowa City, Iowa, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tyson S.","family":"Matern","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, The University of Iowa, Iowa City, Iowa, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prabin","family":"Shrestha","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, The University of Iowa, Iowa City, Iowa, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick W.","family":"Hitchon","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, The University of Iowa, Iowa City, Iowa, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,12,29]]},"reference":[{"issue":"3","key":"R1-20261017","doi-asserted-by":"crossref","first-page":"471","DOI":"10.3171\/2020.6.SPINE191378","article-title":"Long-term radiographic outcomes of expandable versus static cages in transforaminal lumbar interbody fusion","volume":"34","author":"Chang","year":"2021","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"R2-20261017","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1007\/s11420-019-09677-z","article-title":"Static versus expandable devices provide similar clinical outcomes following minimally invasive transforaminal lumbar interbody fusion","volume":"16","author":"Khechen","year":"2020","journal-title":"HSS J"},{"issue":"1","key":"R3-20261017","doi-asserted-by":"crossref","first-page":"61","DOI":"10.31616\/asj.2021.0486","article-title":"Static versus expandable interbody fusion devices: a comparison of 1-year clinical and radiographic outcomes in minimally invasive transforaminal lumbar interbody fusion","volume":"17","author":"Ledesma","year":"2023","journal-title":"Asian Spine J"},{"key":"R4-20261017","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.wneu.2021.11.056","article-title":"Expandable versus static transforaminal lumbar interbody fusion cages: 1-year radiographic parameters and patient-reported outcomes","volume":"159","author":"Woodward","year":"2022","journal-title":"World Neurosurg"},{"issue":"8","key":"R5-20261017","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1177\/2192568219886278","article-title":"Comparative effectiveness of expandable versus static interbody spacers via MIS LLIF: a 2-year radiographic and clinical outcomes study","volume":"10","author":"Li","year":"2019","journal-title":"Glob Spine J"},{"issue":"7","key":"R6-20261017","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1097\/BSD.0000000000001737","article-title":"Static versus expandable cages in minimally invasive lateral lumbar interbody fusion: a systematic review and meta-analysis","volume":"38","author":"Beyer","year":"2025","journal-title":"Clin Spine Surg"},{"issue":"1","key":"R7-20261017","doi-asserted-by":"crossref","first-page":"62","DOI":"10.21037\/jss.2018.03.16","article-title":"Clinical and radiographic analysis of expandable versus static lateral lumbar interbody fusion devices with two-year follow-up","volume":"4","author":"Frisch","year":"2018","journal-title":"J Spine Surg"},{"issue":"1","key":"R8-20261017","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1093\/neuros\/nyw177","article-title":"Expandable vs static cages in transforaminal lumbar interbody fusion: radiographic comparison of segmental and lumbar sagittal angles","volume":"81","author":"Yee","year":"2017","journal-title":"Neurosurgery"},{"key":"R9-20261017","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1016\/j.wneu.2019.03.284","article-title":"Assessing the difference in clinical and radiologic outcomes between expandable cage and nonexpandable cage among patients undergoing minimally invasive transforaminal interbody fusion: a systematic review and meta-analysis","volume":"127","author":"Alvi","year":"2019","journal-title":"World Neurosurg"},{"issue":"2","key":"R10-20261017","doi-asserted-by":"crossref","first-page":"265","DOI":"10.14444\/8422","article-title":"Lateral lumbar interbody fusion using expandable vs static titanium interbody cages: a prospective cohort study of clinical and radiographic outcomes","volume":"17","author":"Huo","year":"2023","journal-title":"Int J Spine Surg"},{"issue":"3","key":"R11-20261017","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1111\/os.12119","article-title":"Comparison of one versus two cages in lumbar interbody fusion for degenerative lumbar spinal disease: a meta-analysis","volume":"6","author":"Liu","year":"2014","journal-title":"Orthop Surg"},{"issue":"4","key":"R12-20261017","doi-asserted-by":"crossref","first-page":"854","DOI":"10.14245\/ns.2142248.124","article-title":"Outcomes of transforaminal lumbar interbody fusion using unilateral versus bilateral interbody cages","volume":"18","author":"Lynch","year":"2021","journal-title":"Neurospine"},{"issue":"10","key":"R13-20261017","doi-asserted-by":"crossref","first-page":"1352","DOI":"10.1302\/0301-620X.90B10.21078","article-title":"Posterior lumbar interbody fusion for adult isthmic spondylolisthesis","volume":"90-B","author":"Suh","year":"2008","journal-title":"J Bone Joint Surg Br"},{"issue":"5","key":"R14-20261017","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1007\/s00586-003-0668-y","article-title":"A two-cage reconstruction versus a single mega-cage reconstruction for lumbar interbody fusion: an experimental comparison","volume":"13","author":"Murakami","year":"2004","journal-title":"Eur Spine J"},{"issue":"2","key":"R15-20261017","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1177\/2192568218779991","article-title":"Biomechanical analysis of cortical versus pedicle screw fixation stability in TLIF, PLIF, and XLIF applications","volume":"9","author":"Nomoto","year":"2018","journal-title":"Glob Spine J"},{"issue":"8","key":"R16-20261017","doi-asserted-by":"crossref","first-page":"e240","DOI":"10.1097\/BSD.0b013e31824c820c","article-title":"Would an anatomically shaped lumbar interbody cage provide better stability? An in vitro cadaveric biomechanical evaluation","volume":"25","author":"Tsitsopoulos","year":"2012","journal-title":"J Spinal Disord Tech"},{"issue":"8","key":"R17-20261017","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1016\/j.clinbiomech.2008.02.008","article-title":"Comparison of cage designs for transforaminal lumbar interbody fusion: a biomechanical study","volume":"23","author":"Cho","year":"2008","journal-title":"Clin Biomech (Bristol)"},{"issue":"4","key":"R18-20261017","doi-asserted-by":"crossref","first-page":"e65","DOI":"10.1097\/01.BRS.0000113034.74567.86","article-title":"Transforaminal lumbar interbody fusion","volume":"29","author":"Harris","year":"2004","journal-title":"Spine"},{"issue":"9","key":"R19-20261017","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1016\/j.spinee.2011.06.015","article-title":"Biomechanical analysis of a novel posterior construct in a transforaminal lumbar interbody fusion model an in vitro study","volume":"11","author":"Sethi","year":"2011","journal-title":"Spine J"},{"issue":"4","key":"R20-20261017","doi-asserted-by":"crossref","first-page":"363","DOI":"10.3171\/SPI.2008.9.10.363","article-title":"Biomechanical evaluation of different asymmetrical posterior stabilization methods for minimally invasive transforaminal lumbar interbody fusion","volume":"9","author":"Schleicher","year":"2008","journal-title":"J Neurosurg Spine"},{"issue":"5","key":"R21-20261017","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1016\/j.spinee.2013.06.103","article-title":"Stability of transforaminal lumbar interbody fusion in the setting of retained facets and posterior fixation using transfacet or standard pedicle screws","volume":"15","author":"Chin","year":"2015","journal-title":"Spine J"},{"issue":"6","key":"R22-20261017","doi-asserted-by":"crossref","first-page":"700","DOI":"10.3171\/2009.12.SPINE09123","article-title":"Biomechanical comparison of single-level posterior versus transforaminal lumbar interbody fusions with bilateral pedicle screw fixation: segmental stability and the effects on adjacent motion segments","volume":"12","author":"Sim","year":"2010","journal-title":"J Neurosurg Spine"},{"issue":"24","key":"R23-20261017","doi-asserted-by":"crossref","first-page":"2753","DOI":"10.1097\/00007632-200212150-00003","article-title":"One versus two BAK fusion cages in posterior lumbar interbody fusion to L4\u2013L5 degenerative spondylolisthesis","volume":"27","author":"Zhao","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"issue":"4","key":"R24-20261017","doi-asserted-by":"crossref","first-page":"463","DOI":"10.3171\/2024.4.SPINE231007","article-title":"Transforaminal lumbar interbody fusion subsidence: computed tomography analysis of incidence, associated risk factors, and impact on outcomes","volume":"41","author":"Levy","year":"2024","journal-title":"J Neurosurg Spine"}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000001884","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T17:01:20Z","timestamp":1792256480000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000001884"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,29]]},"references-count":24,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1227\/ons.0000000000001884","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,29]]},"assertion":[{"value":"2025-08-27","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-27","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}