{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:15:54Z","timestamp":1786122954930,"version":"build-2736575974"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND AND OBJECTIVES:<\/jats:title>\n                    <jats:p>Flow diversion is an established treatment strategy for intracranial aneurysms; however, incomplete aneurysm occlusion remains a clinically relevant challenge. Adequate stent\u2013vessel wall apposition is considered critical for aneurysm healing, yet the impact of longitudinal malapposition on long-term outcomes has not been well defined. We aimed to evaluate whether longitudinal stent malapposition detected on cone-beam computed tomography (CBCT) after microcatheter removal is associated with incomplete aneurysm occlusion after Pipeline flow diversion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>We retrospectively analyzed 54 intracranial aneurysms treated exclusively with the Pipeline embolization device between 2019 and 2024. In coil-assisted cases, coils were delivered through a jailed 0.0165-inch microcatheter (SL-10). CBCT was routinely obtained immediately after microcatheter removal and before angioplasty to assess intrinsic stent configuration. Longitudinal malapposition was defined as incomplete stent\u2013vessel wall apposition measuring \u22655 mm. The primary end point was aneurysm occlusion at 12 months graded by the O'Kelly-Marotta (OKM) scale. Incomplete occlusion was defined as OKM grades A-C.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      At 12 months, complete occlusion (OKM D) was achieved in 36 aneurysms (67%), whereas 18 (33%) demonstrated incomplete occlusion. Longitudinal malapposition \u22655 mm was identified in 7 aneurysms (13%). Incomplete occlusion occurred in 71% of aneurysms with malapposition compared with 28% without malapposition (odds ratio 6.5, 95% CI 1.1-37.8;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .03). In coil-assisted cases, malapposition was observed in 4 of 31 aneurysms (13%), all of which resulted in incomplete occlusion.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Longitudinal malapposition \u22655 mm detected on CBCT after microcatheter removal was significantly associated with incomplete aneurysm occlusion at 12 months after Pipeline flow diversion. This association was particularly evident in coil-assisted procedures. These findings suggest that longitudinal malapposition may represent a clinically relevant and potentially modifiable procedural factor, and that CBCT assessment after catheter removal may help guide procedural optimization and risk stratification.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1227\/ons.0000000000002160","type":"journal-article","created":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T13:00:52Z","timestamp":1786107652000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Longitudinal Stent Malapposition After Microcatheter Removal Is Associated With Incomplete Occlusion After Pipeline Flow Diversion"],"prefix":"10.1227","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-9498-3557","authenticated-orcid":false,"given":"Kazuaki","family":"Okamura","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoichi","family":"Morofuji","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan;"},{"name":"Department of Neurosurgery, Showa Medical University Hospital, Shinagawa-ku, Tokyo, Japan;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobutaka","family":"Horie","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tsuyoshi","family":"Izumo","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Gifu University Graduate School of Medicine, Gifu, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takayuki","family":"Matsuo","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,8,7]]},"reference":[{"issue":"1","key":"R1-20260807","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1093\/neuros\/nyw014","article-title":"Long-term clinical and angiographic outcomes following pipeline embolization device treatment of complex internal carotid artery aneurysms: five-year results of the pipeline for uncoilable or failed aneurysms trial","volume":"80","author":"Becske","year":"2017","journal-title":"Neurosurgery"},{"issue":"3","key":"R2-20260807","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1148\/radiol.13120099","article-title":"Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial","volume":"267","author":"Becske","year":"2013","journal-title":"Radiology"},{"issue":"8","key":"R3-20260807","doi-asserted-by":"crossref","first-page":"1436","DOI":"10.3174\/ajnr.A3246","article-title":"Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results","volume":"33","author":"Saatci","year":"2012","journal-title":"AJNR Am J Neuroradiol"},{"issue":"6","key":"R4-20260807","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.3174\/ajnr.A2023","article-title":"Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the pipeline embolization device","volume":"31","author":"Szikora","year":"2010","journal-title":"AJNR Am J Neuroradiol"},{"issue":"8","key":"R5-20260807","doi-asserted-by":"crossref","first-page":"1567","DOI":"10.3174\/ajnr.A3913","article-title":"Analysis of hemodynamics and aneurysm occlusion after flow-diverting treatment in rabbit models","volume":"35","author":"Cebral","year":"2014","journal-title":"AJNR Am J Neuroradiol"},{"issue":"2","key":"R6-20260807","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1161\/STROKEAHA.112.678151","article-title":"Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis","volume":"44","author":"Brinjikji","year":"2013","journal-title":"Stroke"},{"issue":"12","key":"R7-20260807","doi-asserted-by":"crossref","first-page":"2295","DOI":"10.3174\/ajnr.A5375","article-title":"Predictors of incomplete occlusion following pipeline embolization of intracranial aneurysms: is it less effective in older patients?","volume":"38","author":"Adeeb","year":"2017","journal-title":"AJNR Am J Neuroradiol"},{"issue":"2","key":"R8-20260807","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1177\/159101991001600204","article-title":"A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents","volume":"16","author":"O\u2019kelly","year":"2010","journal-title":"Interv Neuroradiol"},{"issue":"10","key":"R9-20260807","doi-asserted-by":"crossref","first-page":"1966","DOI":"10.3174\/ajnr.A5343","article-title":"Clinical impact of flat panel volume CT angiography in evaluating the accurate intraoperative deployment of flow-diverter stents","volume":"38","author":"Claren\u00e7on","year":"2017","journal-title":"AJNR Am J Neuroradiol"},{"key":"R10-20260807","doi-asserted-by":"crossref","first-page":"e388","DOI":"10.1016\/j.wneu.2020.12.068","article-title":"Flow diverter apposition in patients with large or giant intracranial aneurysms evaluated on three-dimensional fusion images acquired by high-resolution cone-beam computed tomography and digital subtraction angiography","volume":"147","author":"Kato","year":"2021","journal-title":"World Neurosurg"},{"issue":"1","key":"R11-20260807","doi-asserted-by":"crossref","first-page":"16","DOI":"10.3174\/ajnr.A8079","article-title":"Correlation of flow diverter malapposition at the aneurysm neck with incomplete aneurysm occlusion in patients with small intracranial aneurysms: a single-center experience","volume":"45","author":"Long","year":"2023","journal-title":"AJNR Am J Neuroradiol"},{"issue":"9","key":"R12-20260807","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1136\/neurintsurg-2017-013739","article-title":"Single-stage flow diversion with adjunctive coiling for cerebral aneurysm: outcomes and technical considerations in 72 cases","volume":"10","author":"Bender","year":"2018","journal-title":"J Neurointerv Surg"},{"issue":"3","key":"R13-20260807","doi-asserted-by":"crossref","first-page":"2221","DOI":"10.1007\/s10143-021-01719-7","article-title":"Pipeline flow diversion with adjunctive coil embolization for internal carotid artery aneurysms following an intradural component: results in 46 consecutive aneurysms from a Japanese single-center experience","volume":"45","author":"Akiyama","year":"2022","journal-title":"Neurosurg Rev"},{"issue":"2","key":"R14-20260807","doi-asserted-by":"crossref","first-page":"272","DOI":"10.3174\/ajnr.A8443","article-title":"Clinical outcome of pipeline embolization device with and without coils to treat intracranial aneurysm: a systematic review and meta-analysis","volume":"46","author":"Kesumayadi","year":"2025","journal-title":"AJNR Am J Neuroradiol"},{"issue":"6","key":"R15-20260807","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1159\/000490577","article-title":"Usefulness of cone beam intra-arterial CTA for evaluation of flow diverters: a practical approach for daily use","volume":"7","author":"Reyes","year":"2018","journal-title":"Interv Neurol"},{"issue":"1","key":"R16-20260807","doi-asserted-by":"crossref","first-page":"19","DOI":"10.2176\/nmc.oa.2021-0203","article-title":"Long-term follow-up results after flow diverter therapy using the pipeline embolization device for large or giant unruptured internal carotid artery aneurysms: single-center retrospective analysis in the Japanese population","volume":"62","author":"Fujii","year":"2022","journal-title":"Neurol Med Chir (Tokyo)"},{"issue":"3","key":"R17-20260807","doi-asserted-by":"crossref","first-page":"e0264688","DOI":"10.1371\/journal.pone.0264688","article-title":"Effect of flow diverter stent malposition on intracranial aneurysm hemodynamics-an experimental framework using stereoscopic particle image velocimetry","volume":"17","author":"Roloff","year":"2022","journal-title":"PLoS One"},{"issue":"1","key":"R18-20260807","doi-asserted-by":"crossref","first-page":"87","DOI":"10.3174\/ajnr.A7350","article-title":"Parent artery straightening after flow-diverter stenting improves the odds of aneurysm occlusion","volume":"43","author":"Janot","year":"2022","journal-title":"AJNR Am J Neuroradiol"},{"issue":"1","key":"R19-20260807","doi-asserted-by":"crossref","first-page":"20","DOI":"10.3174\/ajnr.A2370","article-title":"Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment","volume":"32","author":"Kulcs\u00e1r","year":"2011","journal-title":"AJNR Am J Neuroradiol"},{"key":"R20-20260807","article-title":"Delayed aneurysm rupture after flow-diverter deployment in unruptured aneurysms: a systematic review and meta-analysis","author":"Rodriguez-Eraz\u00fa","journal-title":"J Neurointerv Surg"}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000002160","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T13:00:55Z","timestamp":1786107655000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000002160"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,7]]},"references-count":20,"URL":"https:\/\/doi.org\/10.1227\/ons.0000000000002160","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,7]]},"assertion":[{"value":"2026-03-20","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-16","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}