{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T13:12:01Z","timestamp":1789132321656,"version":"build-2803163510"},"reference-count":8,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND AND OBJECTIVES:<\/jats:title>\n                    <jats:p>Intraoperative neuronavigation techniques are limited in peripheral nerve surgery compared with cranial and spinal neurosurgery. This study describes a multicenter, single institutional experience using a radar reflector system as a novel adjunct for intraoperative localization in peripheral nerve surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>This is a retrospective multicenter, single institution case series of the first 21 patients who underwent peripheral nerve surgery with the use of radar reflector\u2013guided localizer between September 2023 and June 2025. All surgeries and pre- and postoperative assessments were performed by 2 senior peripheral nerve neurosurgeons. Patients underwent preoperative ultrasound-guided percutaneous placement of 1 or more implantable radar reflectors by a single musculoskeletal radiologist at a specified anatomic location requested by the surgeon. Intraoperative localization was performed using a handheld radar detector providing real-time audio and distance feedback to reflector location. Data collection including demographics, indications for surgery, use of the nerve navigation system, success of intraoperative reflector localization and retrieval, and adverse outcomes were performed and descriptive results are presented.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>Twenty-one patients (14 male, 7 female; mean age 57 years) were included in this feasibility analysis. Surgical indications were categorized into 3 groups: nerve tumor resection (n = 7), nerve exploration\/neurolysis\/repair (n = 10), and nerve transfer (n = 4). Radar reflector was placed 0\u2013164 days before surgery (mean 19 days). Reflectors were successfully identified and removed in all cases, with no device-related complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Radar reflector\u2013guided navigation in peripheral nerve surgery facilitated identification of deep, nonpalpable lesions or anatomically distorted nerves, including in patients with previous surgery, trauma, radiation, or high body mass index. Use of this intraoperative nerve navigation technique is a feasible and safe adjunct for peripheral nerve surgeons. This technique shows promise as a valuable adjunct for enhancing surgical efficiency without compromising safety. Further studies are warranted to validate these findings in a larger cohort and establish best practices for implementation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1227\/ons.0000000000002200","type":"journal-article","created":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T13:02:15Z","timestamp":1789131735000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["A Novel Intraoperative Peripheral Nerve Surgery Navigation Technique Using Radar Reflector Localization: Case Series"],"prefix":"10.1227","author":[{"given":"Katelyn","family":"Candido","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ben","family":"Gu","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chantal","family":"Chahine","sequence":"additional","affiliation":[{"name":"Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antje L.","family":"Greenfield","sequence":"additional","affiliation":[{"name":"Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric L.","family":"Zager","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zarina S.","family":"Ali","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9,11]]},"reference":[{"issue":"8","key":"R1-20260911","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1177\/0003134820939903","article-title":"Savi Scout radar localization versus wire localization for breast biopsy regarding positive margin, complication, and reoperation rates","volume":"86","author":"Tingen","year":"2020","journal-title":"Am Surg."},{"issue":"10","key":"R2-20260911","doi-asserted-by":"crossref","first-page":"3168","DOI":"10.1245\/s10434-016-5405-y","article-title":"A prospective, single-arm, multi-site, clinical evaluation of a nonradioactive surgical guidance technology for the location of nonpalpable breast lesions during excision","volume":"23","author":"Cox","year":"2016","journal-title":"Ann Surg Oncol."},{"issue":"2","key":"R3-20260911","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1148\/radiol.2017161661","article-title":"Beyond wires and seeds: reflector-guided breast lesion localization and excision","volume":"284","author":"Mango","year":"2017","journal-title":"Radiology."},{"issue":"4","key":"R4-20260911","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1177\/1553350619843757","article-title":"SAVI SCOUT as a novel localization and surgical navigation system for more accurate localization and resection of pulmonary nodules","volume":"26","author":"Cornella","year":"2019","journal-title":"Surg Innov."},{"issue":"6","key":"R5-20260911","doi-asserted-by":"crossref","first-page":"3366","DOI":"10.1245\/s10434-020-09229-4","article-title":"Intraoperative localization using an implanted radar reflector facilitates resection of nonpalpable trunk and extremity sarcoma","volume":"28","author":"Broman","year":"2021","journal-title":"Ann Surg Oncol."},{"issue":"3","key":"R7-20260911","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1007\/s10549-018-4709-y","article-title":"Safety and feasibility of breast lesion localization using magnetic seeds (Magseed): a multi-centre, open-label cohort study","volume":"169","author":"Harvey","year":"2018","journal-title":"Breast Cancer Res Treat."},{"issue":"3","key":"R8-20260911","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1093\/ons\/opw009","article-title":"Preoperative ultrasound-guided wire localization of the lateral femoral cutaneous nerve","volume":"13","author":"Hanna","year":"2017","journal-title":"Oper Neurosurg."},{"issue":"10","key":"R9-20260911","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1007\/BF02574518","article-title":"Ultrasound-guided lumpectomy of nonpalpable breast cancer versus wire-guided resection: a randomized clinical trial","volume":"9","author":"Rahusen","year":"2002","journal-title":"Ann Surg Oncol."}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000002200","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T13:02:16Z","timestamp":1789131736000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1227\/ons.0000000000002200"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,11]]},"references-count":8,"URL":"https:\/\/doi.org\/10.1227\/ons.0000000000002200","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,11]]},"assertion":[{"value":"2025-11-06","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-27","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}