{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T08:46:19Z","timestamp":1777884379329,"version":"3.51.4"},"reference-count":20,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2001,3,1]],"date-time":"2001-03-01T00:00:00Z","timestamp":983404800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2001,3,1]]},"abstract":"<jats:p>The paper describes the development of a passive\/active orthosis for people with limited anti-gravity strength in their arms. This is symptomatic of conditions such as muscular dystrophy and spinal muscular atrophy. A passive orthosis was designed and developed using linear elastic elements. The system is being tested with children with disabilities and preliminary results are encouraging. An RT200 robot was also used as a test-bed for an active orthosis. The robot was instrumented with a six-axis force\/torque sensor at the end-effector. The force acted as the input to the robot. The robot kinematics and dynamics were modelled. A number of control schemes were implemented on the test-bed including force proportional to velocity and acceleration; these schemes were evaluated with two subjects.<\/jats:p>","DOI":"10.1243\/0954411011535858","type":"journal-article","created":{"date-parts":[[2002,10,1]],"date-time":"2002-10-01T19:24:52Z","timestamp":1033500292000},"page":"267-274","source":"Crossref","is-referenced-by-count":18,"title":["Towards the control of a powered orthosis for people with muscular dystrophy"],"prefix":"10.1177","volume":"215","author":[{"given":"T","family":"Rahman","sequence":"first","affiliation":[{"name":"Alfred I. duPont Hospital for Children Department of Research Wilmington, Delaware, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R","family":"Ramanathan","sequence":"additional","affiliation":[{"name":"University of Pennsylvania Philadelphia, Pennsylvania, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S","family":"Stroud","sequence":"additional","affiliation":[{"name":"Alfred I. duPont Hospital for Children Department of Research Wilmington, Delaware, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W","family":"Sample","sequence":"additional","affiliation":[{"name":"Alfred I. duPont Hospital for Children Department of Research Wilmington, Delaware, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R","family":"Seliktar","sequence":"additional","affiliation":[{"name":"Drexel University School of Biomedical Engineering, Science and Health Systems Philadelphia, Pennsylvania, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W","family":"Harwin","sequence":"additional","affiliation":[{"name":"University of Reading Department of Cybernetics UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M","family":"Alexander","sequence":"additional","affiliation":[{"name":"Alfred I. duPont Hospital for Children Department of Rehabilitation Medicine Wilmington, Delaware, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M","family":"Scavina","sequence":"additional","affiliation":[{"name":"Alfred I. duPont Hospital for Children Department of Neurology Wilmington, Delaware, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2001,3,1]]},"reference":[{"key":"bibr1-0954411011535858","volume-title":"Atlas of Orthotic and Assistive Devices\u2014Biomechanical Principles and Applications","author":"Lunsford T. R.","year":"1995"},{"key":"bibr2-0954411011535858","doi-asserted-by":"publisher","DOI":"10.1097\/00002060-199509001-00003"},{"key":"bibr3-0954411011535858","doi-asserted-by":"publisher","DOI":"10.3233\/TAD-1996-5207"},{"key":"bibr4-0954411011535858","volume-title":"Rehabilitation Medicine: Principles and Practice","author":"Bach J. R.","year":"1993"},{"key":"bibr5-0954411011535858","doi-asserted-by":"publisher","DOI":"10.1016\/0887-8994(95)00251-0"},{"key":"bibr6-0954411011535858","first-page":"186","volume-title":"Pediatric Rehabilitation","author":"Alexander M. A.","year":"1992"},{"key":"bibr7-0954411011535858","doi-asserted-by":"publisher","DOI":"10.3109\/03093648409145360"},{"key":"bibr8-0954411011535858","unstructured":"Engen T. J. Development towards a controllable orthotic system for restoring useful arm and hand actions Orthop. Prosthetic Appliance J., 1963, June."},{"key":"bibr9-0954411011535858","doi-asserted-by":"crossref","unstructured":"LeBlanc M., Leifer L. Environmental control and robotic manipulation aids Engng Medicine Biol. Mag., 1982, 16\u201322.","DOI":"10.1109\/EMB-M.1982.5005839"},{"key":"bibr10-0954411011535858","unstructured":"Allen J. R., Karchak A.Jr, Bontrager E. L. Final project report, design and fabricate a pair of Rancho anthropomorphic manipulators. Technical Report, The Rancho Los Amigos Hospital Inc., Downey, California, 1972."},{"key":"bibr11-0954411011535858","volume-title":"Advances in External Control of Human Extremities","author":"Moe M. L.","year":"1973"},{"key":"bibr12-0954411011535858","doi-asserted-by":"publisher","DOI":"10.1038\/sc.1974.47"},{"issue":"2","key":"bibr13-0954411011535858","first-page":"155","volume":"2","author":"Benjuya N.","year":"1990","journal-title":"J. Prosthetics Orthosis"},{"key":"bibr14-0954411011535858","unstructured":"Galway R., Naumann S., Sauter S., Somerville S. The evaluation of a powered orthotic device for the enhancement of upper-limb movement (PODEUM). Final report submitted to The National Health Research and Development Program of Health and Welfare Canada, Project 6606-3835-59, 1991."},{"key":"bibr15-0954411011535858","doi-asserted-by":"crossref","unstructured":"Homma K., Arai T. Design of an upper limb motion assist system with parallel mechanism In Proceedings of the IEEE International Conference on Robotics and Automation, 1995, 1302\u20131307.","DOI":"10.1109\/ROBOT.1995.525460"},{"key":"bibr16-0954411011535858","unstructured":"Johnson G. R., Buckley M. A. Development of a new motorized upper limb orthotic system (MULOS). In Proceedings of the Rehabilitation Engineering Society of North America, Pittsburgh, Pennsylvania, June 1997, pp. 399\u2013401."},{"key":"bibr17-0954411011535858","unstructured":"Sample W., Ramanathan R., Rahman T., Eberhardt S., Seliktar R., Alexander M. Design and preliminary evaluation of a functional upper arm orthosis. In Proceedings of the Rehabilitation Engineering Society of North America, Long Beach, California, June 1999, pp. 137\u2013139."},{"key":"bibr18-0954411011535858","doi-asserted-by":"crossref","unstructured":"Ulrich N., Kumar K. Passive mechanical gravity compensation for robot manipulators In Proceedings of the 1991 IEEE International Conference on Robotics and Automation, Sacramento, California, 1991, Vol.2, pp. 1536\u20131541.","DOI":"10.1109\/ROBOT.1991.131834"},{"key":"bibr19-0954411011535858","first-page":"564","volume-title":"Proceedings of the Sixth CISM-IFToMM Symposium on Theory and Practice of Robots and Manipulators","author":"Herve J. M.","year":"1986"},{"key":"bibr20-0954411011535858","doi-asserted-by":"publisher","DOI":"10.1115\/1.2826738"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1243\/0954411011535858","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1243\/0954411011535858","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T02:23:12Z","timestamp":1777602192000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1243\/0954411011535858"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,3,1]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2001,3,1]]}},"alternative-id":["10.1243\/0954411011535858"],"URL":"https:\/\/doi.org\/10.1243\/0954411011535858","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,3,1]]}}}