{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T08:50:52Z","timestamp":1777884652261,"version":"3.51.4"},"reference-count":11,"publisher":"SAGE Publications","issue":"8","license":[{"start":{"date-parts":[[2008,11,1]],"date-time":"2008-11-01T00:00:00Z","timestamp":1225497600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2008,11,1]]},"abstract":"<jats:p>\n                    Debris-induced osteolysis due to surface wear is a potential long-term problem in total knee replacements (TKRs). Wear between the tibial tray and ultra-high molecular weight polyethylene insert is thought to contribute to the wear. This study investigated the influence of tibial tray design on the wear of fixed-bearing TKRs. Specifically, this study investigated the influence of the material's surface finish and design characteristics of the locking mechanism of the tibial tray on the wear in fixed-bearing knees for both cruciate-retaining (CR) and posterior-stabilized designs. A new fixed-bearing tibial tray design using Co\u2014Cr and with an improved locking mechanism significantly reduced polyethylene wear from 22.8 \u00b1 6.0 mm\n                    <jats:sup>3<\/jats:sup>\n                    per 10\n                    <jats:sup>6<\/jats:sup>\n                    cycles to 15.9 \u00b1 2.9 mm\n                    <jats:sup>3<\/jats:sup>\n                    per 10\n                    <jats:sup>6<\/jats:sup>\n                    cycles compared with a previous titanium alloy tray with a CR design. The wear rates were similar to those of a fixed-bearing insert clamped into a tibial tray, suggesting that the decrease in wear was due to a reduction in backside wear. There was no significant difference between the wear rates of a cruciate-retaining design and a posterior-stabilized design under the two kinematic conditions tested.\n                  <\/jats:p>","DOI":"10.1243\/09544119jeim434","type":"journal-article","created":{"date-parts":[[2008,12,12]],"date-time":"2008-12-12T21:45:50Z","timestamp":1229118350000},"page":"1289-1293","source":"Crossref","is-referenced-by-count":6,"title":["The influence of tibial tray design on the wear of fixed-bearing total knee replacements"],"prefix":"10.1177","volume":"222","author":[{"given":"A","family":"Galvin","sequence":"first","affiliation":[{"name":"Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L M","family":"Jennings","sequence":"additional","affiliation":[{"name":"Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H M","family":"McEwen","sequence":"additional","affiliation":[{"name":"DePuy International Ltd, Leeds"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J","family":"Fisher","sequence":"additional","affiliation":[{"name":"Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2008,12,12]]},"reference":[{"key":"bibr1-09544119JEIM434","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.1036"},{"key":"bibr2-09544119JEIM434","doi-asserted-by":"publisher","DOI":"10.1243\/0954411001535219"},{"key":"bibr3-09544119JEIM434","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2004.02.015"},{"key":"bibr4-09544119JEIM434","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200211000-00037"},{"issue":"2","key":"bibr5-09544119JEIM434","first-page":"326","volume":"87","author":"Conditt M. A.","year":"2005","journal-title":"J. Bone Jt Surg. Am."},{"issue":"12","key":"bibr6-09544119JEIM434","first-page":"2702","volume":"87","author":"Collier M. B.","year":"2005","journal-title":"J. Bone Jt Surg. Am."},{"key":"bibr7-09544119JEIM434","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200210000-00017"},{"key":"bibr8-09544119JEIM434","doi-asserted-by":"publisher","DOI":"10.1243\/0954411021536289"},{"key":"bibr9-09544119JEIM434","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(92)90254-X"},{"key":"bibr10-09544119JEIM434","first-page":"840","volume-title":"In Proceedings of the Annual Meeting of the Orthopaedic Research Society, San Francisco, California, USA","author":"McNulty D.","year":"2004"},{"key":"bibr11-09544119JEIM434","first-page":"80","volume-title":"Annual Meeting Transaction of the Society for Biomaterials, Memphis, Tennessee, USA","author":"McNulty D. E.","year":"2005"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1243\/09544119JEIM434","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1243\/09544119JEIM434","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T02:33:06Z","timestamp":1777602786000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1243\/09544119JEIM434"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,11,1]]},"references-count":11,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2008,11,1]]}},"alternative-id":["10.1243\/09544119JEIM434"],"URL":"https:\/\/doi.org\/10.1243\/09544119jeim434","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,11,1]]}}}