{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T23:40:38Z","timestamp":1792194038537,"version":"4.4.0"},"reference-count":28,"publisher":"Japanese Circulation Society","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Circ J"],"published-print":{"date-parts":[[2011]]},"DOI":"10.1253\/circj.cj-10-1106","type":"journal-article","created":{"date-parts":[[2011,3,3]],"date-time":"2011-03-03T05:20:21Z","timestamp":1299129621000},"page":"1147-1155","source":"Crossref","is-referenced-by-count":101,"title":["Less Frequent Opening of the Aortic Valve and a Continuous Flow Pump Are Risk Factors for Postoperative Onset of Aortic Insufficiency in Patients With a Left Ventricular Assist Device"],"prefix":"10.1253","volume":"75","author":[{"given":"Masaru","family":"Hatano","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Medicine, Graduate School of Medicine, University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koichiro","family":"Kinugawa","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Graduate School of Medicine, University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taro","family":"Shiga","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Graduate School of Medicine, University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoko","family":"Kato","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Graduate School of Medicine, University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miyoko","family":"Endo","sequence":"additional","affiliation":[{"name":"Department of Organ Transplantation, Graduate School of Medicine, University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Motoyuki","family":"Hisagi","sequence":"additional","affiliation":[{"name":"Department of Therapeutic Strategy for Heart Failure, Graduate School of Medicine, University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Nishimura","sequence":"additional","affiliation":[{"name":"Department of Therapeutic Strategy for Heart Failure, Graduate School of Medicine, University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsushi","family":"Yao","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Graduate School of Medicine, University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasunobu","family":"Hirata","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Graduate School of Medicine, University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shunei","family":"Kyo","sequence":"additional","affiliation":[{"name":"Department of Therapeutic Strategy for Heart Failure, Graduate School of Medicine, University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minoru","family":"Ono","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic Surgery, Graduate School of Medicine, University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryozo","family":"Nagai","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Graduate School of Medicine, University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"330","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jjcc.2010.05.010"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1253\/circj.CJ-10-0770"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Saito S, Matsumiya G, Sakaguchi T, Miyagawa S, Yoshikawa Y, Yamauchi T, et al. Risk factor analysis of long-term support with left ventricular assist system. Circ J 2010; 74: 715-722.","DOI":"10.1253\/circj.CJ-09-0747"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Feldman CM, Silver MA, Sobieski MA, Slaughter MS. Management of aortic insufficiency with continuous flow left ventricular assist devices: Bioprosthetic valve replacement. J Heart Lung Transplant 2006; 25: 1410-1412.","DOI":"10.1016\/j.healun.2006.10.004"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Bryant AS, Holman WL, Nanda NC, Vengala S, Blood MS, Pamboukian SV, et al. Native aortic valve insufficiency in patients with left ventricular assist devices. Ann Thorac Surg 2006; 81: e6-e8.","DOI":"10.1016\/j.athoracsur.2005.08.072"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Park SJ, Liao KK, Segurola R, Madhu KP, Miller LW. Management of aortic insufficiency in patients with left ventricular assist devices: A simple coaptation stitch method (Park's stitch). J Thorac Cardiovasc Surg 2004; 127: 264-266.","DOI":"10.1016\/S0022-5223(03)01301-1"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Samuels LE, Thomas MP, Holmes EC, Narula J, Fitzpatrick J, Wood D, et al. Insufficiency of the native aortic valve and left ventricular assist system inflow valve after support with an implantable left ventricular assist system: Signs, symptoms, and concerns. J Thorac Cardiovasc Surg 2001; 122: 380-381.","DOI":"10.1067\/mtc.2001.114770"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Pak SW, Uriel N, Takayama H, Cappleman S, Song R, Colombo PC, et al. Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices. J Heart Lung Transplant 2010; 29: 1172-1176.","DOI":"10.1016\/j.healun.2010.05.018"},{"key":"9","unstructured":"9. Letsou GV, Connelly JH, Delgado RM 3rd, Myers TJ, Gregoric ID, Smart FW, et al. Is native aortic valve commissural fusion in patients with long-term left ventricular assist devices associated with clinically important aortic insufficiency? J Heart Lung Transplant 2006; 25: 395-399."},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Amir O, Kar B, Delgado RM 3rd, Younis AG, Gregoric ID, Smart FW, et al. Images in cardiovascular medicine: High left ventricular assist device flows resulting from combined native aortic valve and outflow valve regurgitation. Circulation 2005; 111: e34.","DOI":"10.1161\/01.CIR.0000154006.38669.6B"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Cowger J, Pagani FD, Haft JW, Romano MA, Aaronson KD, Kolias TJ. The development of aortic insufficiency in left ventricular assist device-supported patients. Circ Heart Fail 2010; 3: 668-674.","DOI":"10.1161\/CIRCHEARTFAILURE.109.917765"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Mudd JO, Cuda JD, Halushka M, Soderlund KA, Conte JV, Russell SD. Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device. J Heart Lung Transplant 2008; 27: 1269-1274.","DOI":"10.1016\/j.healun.2008.05.029"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa012175"},{"key":"14","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0909938"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Yamazaki K, Kihara S, Akimoto T, Tagusari O, Kawai A, Umezu M, et al. Evaheart: An implantable centrifugal blood pump for long-term circulatory support. Jpn J Thorac Cardiovasc Surg 2002; 50: 461-465.","DOI":"10.1007\/BF02919636"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1253\/circj.70.1421"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-200305000-00005"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Banchs JE, Dawn B, Abdel-Latif A, Qureshi A, Agrawal N, Bouvette M, et al. Acquired aortic cusp fusion after chronic left ventricular assist device support. J Am Soc Echocardiogr 2006; 19: 1401.e1401-e1403.","DOI":"10.1016\/j.echo.2006.05.025"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Nishimura M, Ohtake S, Sawa Y, Fukushima N, Matsumiya G, Matsuda H. Severe aortic valve fusion after nearly three years of support with the novacor left ventricular assist system. J Thorac Cardiovasc Surg 2002; 124: 179-180.","DOI":"10.1067\/mtc.2002.122349"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Baradarian S, Dembitsky WP, Jaski B, Abolhoda A, Adamson R, Chillcot S, et al. Left ventricular outflow tract obstruction associated with chronic ventricular assist device support. ASAIO J 2002; 48: 665-667.","DOI":"10.1097\/00002480-200211000-00016"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21. May-Newman K, Hillen B, Dembitsky W. Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta. ASAIO J 2006; 52: 132-139.","DOI":"10.1097\/01.mat.0000201961.97981.e9"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Khalil HA, Cohn WE, Metcalfe RW, Frazier OH. Preload sensitivity of the Jarvik 2000 and Heartmate II left ventricular assist devices. ASAIO J 2008; 54: 245-248.","DOI":"10.1097\/MAT.0b013e318173e0f4"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Andersen M, Gustafsson F, Madsen PL, Brassard P, Jensen AS, Secher N, et al. Hemodynamic stress echocardiography in patients supported with a continuous-flow left ventricular assist device. JACC Cardiovasc Imaging 2010; 3: 854-859.","DOI":"10.1016\/j.jcmg.2010.06.007"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24. Nishimura T, Tatsumi E, Takaichi S, Taenaka Y, Wakisaka Y, Nakatani T, et al. Prolonged nonpulsatile left heart bypass with reduced systemic pulse pressure causes morphological changes in the aortic wall. Artif Organs 1998; 22: 405-410.","DOI":"10.1046\/j.1525-1594.1998.06137.x"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25. Westaby S, Bertoni GB, Clelland C, Nishinaka T, Frazier OH. Circulatory support with attenuated pulse pressure alters human aortic wall morphology. J Thorac Cardiovasc Surg 2007; 133: 575-576.","DOI":"10.1016\/j.jtcvs.2006.10.014"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26. Garcia S, Kandar F, Boyle A, Colvin-Adams M, Lliao K, Joyce L, et al. Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading. J Heart Lung Transplant 2008; 27: 261-267.","DOI":"10.1016\/j.healun.2007.12.001"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27. Haft J, Armstrong W, Dyke DB, Aaronson KD, Koelling TM, Farrar DJ, et al. Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices. Circulation 2007; 116: I8-I15.","DOI":"10.1161\/CIRCULATIONAHA.106.677898"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28. John R, Mantz K, Eckman P, Rose A, May-Newman K. Aortic valve pathophysiology during left ventricular assist device support. J Heart Lung Transplant 2010; 29: 1321-1329.","DOI":"10.1016\/j.healun.2010.06.006"}],"container-title":["Circulation Journal"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.jstage.jst.go.jp\/article\/circj\/75\/5\/75_CJ-10-1106\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,25]],"date-time":"2021-03-25T03:58:52Z","timestamp":1616644732000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.jstage.jst.go.jp\/article\/circj\/75\/5\/75_CJ-10-1106\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011]]},"references-count":28,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2011]]}},"URL":"https:\/\/doi.org\/10.1253\/circj.cj-10-1106","relation":{},"ISSN":["1346-9843","1347-4820"],"issn-type":[{"value":"1346-9843","type":"print"},{"value":"1347-4820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011]]}}}