{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T04:35:36Z","timestamp":1789533336962,"version":"build-2803163510"},"reference-count":34,"publisher":"Japanese Circulation Society","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Circ J"],"published-print":{"date-parts":[[2012]]},"DOI":"10.1253\/circj.cj-11-0845","type":"journal-article","created":{"date-parts":[[2012,1,18]],"date-time":"2012-01-18T05:20:20Z","timestamp":1326864020000},"page":"698-703","source":"Crossref","is-referenced-by-count":76,"title":["Natural History of Stent Edge Dissection, Tissue Protrusion and Incomplete Stent Apposition Detectable Only on Optical Coherence Tomography After Stent Implantation"],"prefix":"10.1253","volume":"76","author":[{"given":"Teruyoshi","family":"Kume","sequence":"first","affiliation":[{"name":"Department of Cardiology, Kawasaki Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Okura","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kawasaki Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshinori","family":"Miyamoto","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kawasaki Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryotaro","family":"Yamada","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kawasaki Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ken","family":"Saito","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kawasaki Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoko","family":"Tamada","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kawasaki Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Terumasa","family":"Koyama","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kawasaki Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoji","family":"Neishi","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kawasaki Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akihiro","family":"Hayashida","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kawasaki Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takahiro","family":"Kawamoto","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kawasaki Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiyoshi","family":"Yoshida","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kawasaki Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"330","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Honda Y, Fitzgerald PJ. Stent thrombosis: An issue revisited in a changing world. Circulation 2003; 108: 2-5.","DOI":"10.1161\/01.CIR.0000075929.79964.D8"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Choi SY, Witzenbichler B, Maehara A, Lansky AJ, Guagliumi G, Brodie B, et al. Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: A Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy. Circ Cardiovasc Interv 2011; 4: 239-247.","DOI":"10.1161\/CIRCINTERVENTIONS.110.959791"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Uren NG, Schwarzacher SP, Metz JA, Lee DP, Honda Y, Yeung AC, et al. Predictors and outcomes of stent thrombosis: An intravascular ultrasound registry. Eur Heart J 2002; 23: 124-132.","DOI":"10.1053\/euhj.2001.2707"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Steinberg DH, Mintz GS, Mandinov L, Yu A, Ellis SG, Grube E, et al. Long-term impact of routinely detected early and late incomplete stent apposition: An integrated intravascular ultrasound analysis of the TAXUS IV, V, and VI and TAXUS ATLAS workhorse, long lesion, and direct stent studies. JACC Cardiovasc Interv 2010; 3: 486-494.","DOI":"10.1016\/j.jcin.2010.03.007"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Fujii K, Carlier SG, Mintz GS, Yang YM, Moussa I, Weisz G, et al. Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: An intravascular ultrasound study. J Am Coll Cardiol 2005; 45: 995-998.","DOI":"10.1016\/j.jacc.2004.12.066"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Degertekin M, Serruys PW, Tanabe K, Lee CH, Sousa JE, Colombo A, et al. Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions: An intravascular ultrasound analysis. Circulation 2003; 108: 2747-2750.","DOI":"10.1161\/01.CIR.0000103666.25660.77"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Tanabe K, Serruys PW, Degertekin M, Grube E, Guagliumi G, Urbaszek W, et al. Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: Insights from the randomized TAXUS II trial. Circulation 2005; 111: 900-905.","DOI":"10.1161\/01.CIR.0000155607.54922.16"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Hong MK, Mintz GS, Lee CW, Kim YH, Lee SW, Song JM, et al. Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation. Circulation 2004; 109: 881-886.","DOI":"10.1161\/01.CIR.0000116751.88818.10"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Kimura M, Mintz GS, Carlier S, Takebayashi H, Fujii K, Sano K, et al. Outcome after acute incomplete sirolimus-eluting stent apposition as assessed by serial intravascular ultrasound. Am J Cardiol 2006; 98: 436-442.","DOI":"10.1016\/j.amjcard.2006.02.050"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Fujii K, Carlier SG, Mintz GS, Yang YM, Moussa I, Weisz G, et al. Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: An intravascular ultrasound study. J Am Coll Cardiol 2005; 45: 995-998.","DOI":"10.1016\/j.jacc.2004.12.066"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Liu Y, Imanishi T, Kubo T, Tanaka A, Kitabata H, Tanimoto T, et al. Assessment by optical coherence tomography of stent struts across side branch: Comparison of bare-metal stents and drug-elution stents. Circ J 2010; 75: 106-112.","DOI":"10.1253\/circj.CJ-10-0574"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Prati F, Regar E, Mintz GS, Arbustini E, Di Mario C, Jang IK, et al. Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: Physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 2010; 31: 401-415.","DOI":"10.1093\/eurheartj\/ehp433"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Yamaguchi T, Terashima M, Akasaka T, Hayashi T, Mizuno K, Muramatsu T, et al. Safety and feasibility of an intravascular optical coherence tomography image wire system in the clinical setting. Am J Cardiol 2008; 101: 562-567.","DOI":"10.1016\/j.amjcard.2007.09.116"},{"key":"14","unstructured":"14. Kawamori H, Shite J, Shinke T, Otake H, Sawada T, Kato H, et al. The ability of optical coherence tomography to monitor percutaneous coronary intervention: Detailed comparison with intravascular ultrasound. J Invasive Cardiol 2010; 22: 541-545."},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Bouma BE, Tearney GJ, Yabushita H, Shishkov M, Kauffman CR, DeJoseph Gauthier D, et al. Evaluation of intracoronary stenting by intravascular optical coherence tomography. Heart 2003; 89: 317-320.","DOI":"10.1136\/heart.89.3.317"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, et al. Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: Evaluated by optical coherence tomography. Eur Heart J 2007; 28: 961-967.","DOI":"10.1093\/eurheartj\/ehl413"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Katoh H, Shite J, Shinke T, Matsumoto D, Tanino Y, Ogasawara D, et al. Delayed neointimalization on sirolimus-eluting stents: 6-month and 12-month follow up by optical coherence tomography. Circ J 2009; 73: 1033-1037.","DOI":"10.1253\/circj.CJ-08-0746"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Sawada T, Shite J, Negi N, Shinke T, Tanino Y, Ogasawara D, et al. Factors that influence measurements and accurate evaluation of stent apposition by optical coherence tomography: Assessment using a phantom model. Circ J 2009; 73: 1841-1847.","DOI":"10.1253\/circj.CJ-09-0113"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Schroeder S, Baumbach A, Mahrholdt H, Haase KK, Oberhoff M, Herdeg C, et al. The impact of untreated coronary dissections on acute and long-term outcome after intravascular ultrasound guided PTCA. Eur Heart J 2000; 21: 137-145.","DOI":"10.1053\/euhj.1999.1754"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Hong MK, Park SW, Lee NH, Nah DY, Lee CW, Kang DH, et al. Long-term outcomes of minor dissection at the edge of stents detected with intravascular ultrasound. Am J Cardiol 2000; 86: 791-795, A799.","DOI":"10.1016\/S0002-9149(00)01085-7"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21. Sheris SJ, Canos MR, Weissman NJ. Natural history of intravascular ultrasound-detected edge dissections from coronary stent deployment. Am Heart J 2000; 139: 59-63.","DOI":"10.1016\/S0002-8703(00)90309-0"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Okura H, Hayase M, Shimodozono S, Kobayashi T, Sano K, Matsushita T, et al. Mechanisms of acute lumen gain following cutting balloon angioplasty in calcified and noncalcified lesions: An intravascular ultrasound study. Catheter Cardiovasc Interv 2002; 57: 429-436.","DOI":"10.1002\/ccd.10344"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Okura H, Shimodozono S, Hayase M, Bonneau HN, Yock PG, Fitzgerald PJ. Impact of deep vessel wall injury and vessel stretching on subsequent arterial remodeling after balloon angioplasty: A serial intravascular ultrasound study. Am Heart J 2002; 144: 323-328.","DOI":"10.1067\/mhj.2002.122282"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24. Maehara A, Mintz GS, Lansky AJ, Witzenbichler B, Guagliumi G, Brodie B, et al. Volumetric intravascular ultrasound analysis of paclitaxel-eluting and bare metal stents in acute myocardial infarction: The Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction intravascular ultrasound substudy. Circulation 2009; 120: 1875-1882.","DOI":"10.1161\/CIRCULATIONAHA.109.873893"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25. Kimura M, Mintz GS, Carlier S, Takebayashi H, Fujii K, Sano K, et al. Outcome after acute incomplete sirolimus-eluting stent apposition as assessed by serial intravascular ultrasound. Am J Cardiol 2006; 98: 436-442.","DOI":"10.1016\/j.amjcard.2006.02.050"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26. Nakamura M, Kataoka T, Honda Y, Bonneau HN, Hibi K, Kitamura K, et al. Late incomplete stent apposition and focal vessel expansion after bare metal stenting. Am J Cardiol 2003; 92: 1217-1219.","DOI":"10.1016\/j.amjcard.2003.07.037"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27. Okura H, Lee DP, Lo S, Yeung AC, Honda Y, Waksman R, et al. Late incomplete apposition with excessive remodeling of the stented coronary artery following intravascular brachytherapy. Am J Cardiol 2003; 92: 587-590.","DOI":"10.1016\/S0002-9149(03)00728-8"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28. Ako J, Morino Y, Honda Y, Hassan A, Sonoda S, Yock PG, et al. Late incomplete stent apposition after sirolimus-eluting stent implantation: A serial intravascular ultrasound analysis. J Am Coll Cardiol 2005; 46: 1002-1005.","DOI":"10.1016\/j.jacc.2005.05.068"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29. Cook S, Wenaweser P, Togni M, Billinger M, Morger C, Seiler C, et al. Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation 2007; 115: 2426-2434.","DOI":"10.1161\/CIRCULATIONAHA.106.658237"},{"key":"30","doi-asserted-by":"crossref","unstructured":"30. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003; 349: 1315-1323.","DOI":"10.1056\/NEJMoa035071"},{"key":"31","doi-asserted-by":"crossref","unstructured":"31. Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, et al. Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 2005; 293: 2126-2130.","DOI":"10.1001\/jama.293.17.2126"},{"key":"32","doi-asserted-by":"crossref","unstructured":"32. Stone GW, Ellis SG, Cox DA, Hermiller J, O'Shaughnessy C, Mann JT, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004; 350: 221-231.","DOI":"10.1056\/NEJMoa032441"},{"key":"33","doi-asserted-by":"crossref","unstructured":"33. Miyoshi N, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, et al. Comparison by optical coherence tomography of paclitaxel-eluting stents with sirolimus-eluting stents implanted in one coronary artery in one procedure: 6-month follow-up. Circ J 2010; 74: 903-908.","DOI":"10.1253\/circj.CJ-09-0690"},{"key":"34","doi-asserted-by":"crossref","unstructured":"34. Kim JS, Kim TH, Fan C, Lee JM, Kim W, Ko YG, et al. Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation. Circ J 2010; 74: 320-326.","DOI":"10.1253\/circj.CJ-09-0546"}],"container-title":["Circulation Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/76\/3\/76_CJ-11-0845\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,22]],"date-time":"2019-06-22T16:31:16Z","timestamp":1561221076000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/76\/3\/76_CJ-11-0845\/_article"}},"subtitle":["&amp;ndash; Preliminary Observation &amp;ndash;"],"short-title":[],"issued":{"date-parts":[[2012]]},"references-count":34,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2012]]}},"URL":"https:\/\/doi.org\/10.1253\/circj.cj-11-0845","relation":{},"ISSN":["1346-9843","1347-4820"],"issn-type":[{"value":"1346-9843","type":"print"},{"value":"1347-4820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012]]}}}