{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T08:09:50Z","timestamp":1774598990764,"version":"3.50.1"},"reference-count":31,"publisher":"Japanese Circulation Society","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Circ J"],"published-print":{"date-parts":[[2012]]},"DOI":"10.1253\/circj.cj-11-1379","type":"journal-article","created":{"date-parts":[[2012,2,16]],"date-time":"2012-02-16T05:20:32Z","timestamp":1329369632000},"page":"1229-1234","source":"Crossref","is-referenced-by-count":23,"title":["Device Closure of Atrial Septal Defect"],"prefix":"10.1253","volume":"76","author":[{"given":"Hideaki","family":"Ueda","sequence":"first","affiliation":[{"name":"Department of Cardiology, Kanagawa Children's Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sadamitsu","family":"Yanagi","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kanagawa Children's Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hideaki","family":"Nakamura","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kanagawa Children's Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kentarou","family":"Ueno","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kanagawa Children's Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryouhei","family":"Gatayama","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kanagawa Children's Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshihide","family":"Asou","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Kanagawa Children's Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seiyo","family":"Yasui","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Kanagawa Children's Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"330","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(02)01862-4"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(03)00589-8"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2004.10.066"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Oho S, Ishizawa A, Akagi T, Dodo H, Kato H. Transcatheter closure of atrial septal defects with the Amplatzer septal occluder: A Japanese clinical trial. Circ J 2002; 66: 791-794.","DOI":"10.1253\/circj.66.791"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20211"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. DiBardino DJ, McElhinney DB, Kaza AK, Mayer JE Jr. Analysis of the US Food and Drug Administration Manufacturer and User Facility Device Experience database for adverse events involving Amplatzer septal occluder devices and comparison with the Society of Thoracic Surgery congenital cardiac surgery database. J Thorac Cardiovasc Surg 2009; 137: 1334-1341.","DOI":"10.1016\/j.jtcvs.2009.02.032"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Chun DS, Turrentine MW, Moustapha A, Hoyer MH. Development of aorta-to-right atrial fistula following closure of secundum atrial septal defect using the Amplatzer septal occluder. Catheter Cardiovasc Interv 2003; 58: 246-251.","DOI":"10.1002\/ccd.10434"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2005.08.013"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Li W, Han W, Yu C, Zhang C, Tu Z, Wu S, et al. Severe mitral valve insufficiency after transcatheter atrial septal defect closure with the Amplatzer septal occluder: A device-related complication. J Card Surg 2009; 24: 672-674.","DOI":"10.1111\/j.1540-8191.2009.00871.x"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Moiduddin N, Cheatham JP, Hoffman TM, Phillips AB, Kovalchin JP. Amplatzer septal occluder associated with late pulmonary venous obstruction requiring surgical removal with acquired aorta to left atrial fistula. Am J Cardiol 2009; 103: 1039-1040.","DOI":"10.1016\/j.amjcard.2008.11.057"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Kitano M, Yazaki S, Sugiyama H, Yamada O. The influence of morphological changes in Amplatzer device on the atrial and aortic walls following transcatheter closure of atrial septal defects. J Interv Cardiol 2009; 22: 83-91.","DOI":"10.1111\/j.1540-8183.2008.00421.x"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Pepi M, Tamborini G, Bartorelli AL, Trabattoni D, Maltagliati A, De Vita S, et al. Usefulness of three-dimensional echocardiographic reconstruction of the Amplatzer septal occluder in patients undergoing atrial septal closure. Am J Cardiol 2004; 94: 1343-1347.","DOI":"10.1016\/j.amjcard.2004.07.132"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20443"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Varma C, Benson LN, Silversides C, Yip J, Warr MR, Webb G, et al. Outcomes and alternative techniques for device closure of the large secundum atrial septal defect. Catheter Cardiovasc Interv 2004; 61: 131-139.","DOI":"10.1002\/ccd.10700"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Dalvi BV, Pinto RJ, Gupta A. New technique for device closure of large atrial septal defects. Catheter Cardiovasc Interv 2005; 64: 102-107.","DOI":"10.1002\/ccd.20248"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0304(199712)42:4<388::AID-CCD7>3.0.CO;2-7"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Wilmshurst PT, Nightingale S, Walsh KP, Morrison WL. Clopidogrel reduces migraine with aura after transcatheter closure of persistent foramen ovale and atrial septal defects. Heart 2005; 91: 1173-1175.","DOI":"10.1136\/hrt.2004.047746"},{"issue":"6","key":"18","first-page":"357","volume":"49","author":"TOMITA HIDESHI","year":"2007","ISSN":"https:\/\/id.crossref.org\/issn\/0914-5087","issn-type":"print"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Suda K, Raboisson MJ, Piette E, Dahdah NS, Mir&oacute; J. Reversible atrioventricular block associated with closure of atrial septal defects using the Amplatzer device. J Am Coll Cardiol 2004; 43: 1677-1682.","DOI":"10.1016\/j.jacc.2003.12.042"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Hill SL, Berul CI, Patel HT, Rhodes J, Supran SE, Cao QL, et al. Early ECG abnormalities associated with transcatheter closure of atrial septal defects using the Amplatzer septal occluder. J Interv Card Electrophysiol 2000; 4: 469-474.","DOI":"10.1023\/A:1009852312907"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21. Schoen SP, Boscheri A, Lange SA, Braun MU, Fuhrmann J, Kappert U, et al. Incidence of aortic valve regurgitation and outcome after percutaneous closure of atrial septal defects and patent foramen ovale. Heart 2008; 94: 844-847.","DOI":"10.1136\/hrt.2007.132662"},{"key":"22","unstructured":"22. Ewert P, Berger F, Nagdyman N, Kretschmar O, Dittrich S, Abdul-Khaliq H, et al. Masked left ventricular restriction in elderly patients with atrial septal defects: A contraindication for closure? Catheter Cardiovasc Interv 2001; 52: 177-180."},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Schubert S, Peters B, Abdul-Khaliq H, Nagdyman N, Lange PE, Ewert P, et al. Left ventricular conditioning in the elderly patient to prevent congestive heart failure after transcatheter closure of atrial septal defect. Catheter Cardiovasc Interv 2005; 64: 333-337.","DOI":"10.1002\/ccd.20292"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.1253\/circj.CJ-11-0068"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25. Wang JK, Tsai SK, Lin SM, Chiu SN, Lin MT, Wu MH. Transcatheter closure of atrial septal defect without balloon sizing. Catheter Cardiovasc Interv 2008; 71: 214-221.","DOI":"10.1002\/ccd.21308"},{"key":"26","doi-asserted-by":"publisher","DOI":"10.1002\/1522-726X(200102)52:2<194::AID-CCD1046>3.0.CO;2-4"},{"key":"27","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(02)01711-4"},{"key":"28","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2003.10.030"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29. Rod&eacute;s-Cabau J, Molina C, Serrano-Munuera C, Casald&aacute;liga J, Alvarez-Sabin J, Evangelista A, et al. Migraine with aura related to the percutaneous closure of an atrial septal defect. Catheter Cardiovasc Interv 2003; 60: 540-542.","DOI":"10.1002\/ccd.10713"},{"key":"30","doi-asserted-by":"crossref","unstructured":"30. Yankosvsky AE, Kuritzky A. Transformation into daily migraine with aura following transcutaneous atrial septal defect closure. Headache 2003; 43: 496-498.","DOI":"10.1046\/j.1526-4610.2003.03096.x"},{"key":"31","doi-asserted-by":"publisher","DOI":"10.1253\/circj.CJ-10-1211"}],"container-title":["Circulation Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/76\/5\/76_CJ-11-1379\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,25]],"date-time":"2021-03-25T04:03:50Z","timestamp":1616645030000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/76\/5\/76_CJ-11-1379\/_article"}},"subtitle":["\u2013 Immediate and Mid-Term Results \u2013"],"short-title":[],"issued":{"date-parts":[[2012]]},"references-count":31,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2012]]}},"URL":"https:\/\/doi.org\/10.1253\/circj.cj-11-1379","relation":{},"ISSN":["1346-9843","1347-4820"],"issn-type":[{"value":"1346-9843","type":"print"},{"value":"1347-4820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012]]}}}