{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T03:14:06Z","timestamp":1768706046643,"version":"3.49.0"},"reference-count":28,"publisher":"Japanese Circulation Society","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Circ J"],"published-print":{"date-parts":[[2016]]},"DOI":"10.1253\/circj.cj-15-1051","type":"journal-article","created":{"date-parts":[[2015,12,3]],"date-time":"2015-12-03T22:04:38Z","timestamp":1449180278000},"page":"346-353","source":"Crossref","is-referenced-by-count":44,"title":["Early Recurrence After Pulmonary Vein Isolation of Paroxysmal Atrial Fibrillation With Different Ablation Technologies\u3000\u2013 Prospective Comparison of Radiofrequency vs. Second-Generation Cryoballoon Ablation \u2013"],"prefix":"10.1253","volume":"80","author":[{"given":"Shinsuke","family":"Miyazaki","sequence":"first","affiliation":[{"name":"Cardiology Division, Cardiovascular Center, Tsuchiura Kyodo Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akio","family":"Kuroi","sequence":"additional","affiliation":[{"name":"Cardiology Division, Cardiovascular Center, Tsuchiura Kyodo Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hitoshi","family":"Hachiya","sequence":"additional","affiliation":[{"name":"Cardiology Division, Cardiovascular Center, Tsuchiura Kyodo Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroaki","family":"Nakamura","sequence":"additional","affiliation":[{"name":"Cardiology Division, Cardiovascular Center, Tsuchiura Kyodo Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Taniguchi","sequence":"additional","affiliation":[{"name":"Cardiology Division, Cardiovascular Center, Tsuchiura Kyodo Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Noboru","family":"Ichihara","sequence":"additional","affiliation":[{"name":"Cardiology Division, Cardiovascular Center, Tsuchiura Kyodo Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takamitsu","family":"Takagi","sequence":"additional","affiliation":[{"name":"Cardiology Division, Cardiovascular Center, Tsuchiura Kyodo Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jin","family":"Iwasawa","sequence":"additional","affiliation":[{"name":"Cardiology Division, Cardiovascular Center, Tsuchiura Kyodo Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshito","family":"Iesaka","sequence":"additional","affiliation":[{"name":"Cardiology Division, Cardiovascular Center, Tsuchiura Kyodo Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"330","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Ha\u00efssaguerre M, Ja\u00efs P, Shah DC, Garrigue S, Takahashi A, Lavergne T, et al. Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci. <i>Circulation<\/i> 2000; 101: 1409\u20131417.","DOI":"10.1161\/01.CIR.101.12.1409"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Kojodjojo P, O\u2019Neill MD, Lim PB, Malcolm-Lawes L, Whinnett ZI, Salukhe TV, et al. Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: Medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablation. <i>Heart<\/i> 2010; 96: 1379\u20131384.","DOI":"10.1136\/hrt.2009.192419"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Andrade JG, Khairy P, Macle L, Packer DL, Lehmann JW, Holcomb RG, et al. Incidence and significance of early recurrences of atrial fibrillation after cryoballoon ablation: Insights from the multicenter Sustained Treatment of Paroxysmal Atrial Fibrillation (STOP AF) Trial. <i>Circ Arrhythm Electrophysiol<\/i> 2014; 7: 69\u201375.","DOI":"10.1161\/CIRCEP.113.000586"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Koyama T, Tada H, Sekiguchi Y, Arimoto T, Yamasaki H, Kuroki K, et al. Prevention of atrial fibrillation recurrence with corticosteroids after radiofrequency catheter ablation: A randomized controlled trial. <i>J Am Coll Cardiol<\/i> 2010; 56: 1463\u20131472.","DOI":"10.1016\/j.jacc.2010.04.057"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Richter B, Gwechenberger M, Socas A, Zorn G, Albinni S, Marx M, et al. Markers of oxidative stress after ablation of atrial fibrillation are associated with inflammation, delivered radiofrequency energy and early recurrence of atrial fibrillation. <i>Clin Res Cardiol<\/i> 2012; 101: 217\u2013225.","DOI":"10.1007\/s00392-011-0383-3"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Lim HS, Schultz C, Dang J, Alasady M, Lau DH, Brooks AG, et al. Time course of inflammation, myocardial injury, and prothrombotic response after radiofrequency catheter ablation for atrial fibrillation. <i>Circ Arrhythm Electrophysiol<\/i> 2014; 7: 83\u201389.","DOI":"10.1161\/CIRCEP.113.000876"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA, et al. 2012 HRS\/EHRA\/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. <i>Heart Rhythm<\/i> 2012; 9: 632\u2013696.","DOI":"10.1016\/j.hrthm.2011.12.016"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Ichihara N, Miyazaki S, Taniguchi H, Usui E, Takagi T, Iwasawa J, et al. Simple minimal sedation for catheter ablation of atrial fibrillation. <i>Circ J<\/i> 2015; 79: 346\u2013350.","DOI":"10.1253\/circj.CJ-14-1106"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Miyazaki S, Kuwahara T, Kobori A, Takahashi Y, Takei A, Sato A, et al. Long-term clinical outcome of extensive pulmonary vein isolation-based catheter ablation therapy in patients with paroxysmal and persistent atrial fibrillation. <i>Heart<\/i> 2011; 97: 668\u2013673.","DOI":"10.1136\/hrt.2009.186874"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Miyazaki S, Taniguchi H, Nakamura H, Takagi T, Iwasawa J, Hachiya H, et al. Clinical significance of early recurrence after pulmonary vein antrum isolation in paroxysmal atrial fibrillation: Insight into the mechanism. <i>Circ J<\/i> 2015; 79: 2353\u20132359.","DOI":"10.1253\/circj.CJ-15-0475"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Miyazaki S, Taniguchi H, Kusa S, Uchiyama T, Nakamura H, Hachiya H, et al. Impact of atrial fibrillation termination site and termination mode in catheter ablation on arrhythmia recurrence. <i>Circ J<\/i> 2014; 78: 78\u201384.","DOI":"10.1253\/circj.CJ-13-0838"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Miyazaki S, Hachiya H, Taniguchi H, Nakamura H, Ichihara N, Usui E, et al. Prospective evaluation of bilateral diaphragmatic electromyograms during cryoballoon ablation of atrial fibrillation. <i>J Cardiovasc Electrophysiol<\/i> 2015; 26: 622\u2013628.","DOI":"10.1111\/jce.12671"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Miyazaki S, Taniguchi H, Nakamura H, Hachiya H, Ichihara N, Araki M, et al. Adenosine triphosphate test after cryothermal pulmonary vein isolation: Creating contiguous lesions is essential for eliminating dormant conduction. <i>J Cardiovasc Electrophysiol<\/i> 2015; 26: 1069\u20131074.","DOI":"10.1111\/jce.12726"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Takagi T, Miyazaki S, Kusa S, Taniguchi H, Ichihara N, Iwasawa J, et al. Role of extended external auto-triggered loop recorder monitoring for atrial fibrillation: Validation and utility after catheter ablation procedures. <i>Circ J<\/i> 2014; 78: 2637\u20132642.","DOI":"10.1253\/circj.CJ-14-0610"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Schmidt M, Marschang H, Clifford S, Harald R, Guido R, Oliver T, et al. Trends in inflammatory biomarkers during atrial fibrillation ablation across different catheter ablation strategies. <i>Int J Cardiol<\/i> 2012; 158: 33\u201338.","DOI":"10.1016\/j.ijcard.2010.12.084"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Bordignon S, F\u00fcrnkranz A, Dugo D, Perrotta L, Gunawardene M, Bode F, et al. Improved lesion formation using the novel 28 mm cryoballoon in atrial fibrillation ablation: Analysis of biomarker release. <i>Europace<\/i> 2014; 16: 987\u2013993.","DOI":"10.1093\/europace\/eut400"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Coulombe N, Paulin J, Su W. Improved in vivo performance of second-generation cryoballoon for pulmonary vein isolation. <i>J Cardiovasc Electrophysiol<\/i> 2013; 24: 919\u2013925.","DOI":"10.1111\/jce.12157"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Malmborg H, L\u00f6nnerholm S, Blomstr\u00f6m P, Blomstr\u00f6m-Lundqvist C. Ablation of atrial fibrillation with cryoballoon or duty-cycled radiofrequency pulmonary vein ablation catheter: A randomized controlled study comparing the clinical outcome and safety; the AF-COR study. <i>Europace<\/i> 2013; 15: 1567\u20131573.","DOI":"10.1093\/europace\/eut104"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Bhat T, Teli S, Rijal J, Bhat H, Raza M, Khoueiry G, et al. Neutrophil to lymphocyte ratio and cardiovascular diseases: A review. <i>Expert Rev Cardiovasc Ther<\/i> 2013; 11: 55\u201359.","DOI":"10.1586\/erc.12.159"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Grubman E, Pavri BB, Lyle S, Reynolds C, Denofrio D, Kocovic DZ. Histopathologic effects of radiofrequency catheter ablation in previously infarcted human myocardium. <i>J Cardiovasc Electrophysiol<\/i> 1999; 10: 336\u2013342.","DOI":"10.1111\/j.1540-8167.1999.tb00680.x"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21. Rodriguez LM, Leunissen J, Hoekstra A, Korteling BJ, Smeets JL, Timmermans C, et al. Transvenous cold mapping and cryoablation of the AV node in dogs: Observations of chronic lesions and comparison to those obtained using radiofrequency ablation. <i>J Cardiovasc Electrophysiol<\/i> 1998; 9: 1055\u20131061.","DOI":"10.1111\/j.1540-8167.1998.tb00883.x"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Deneke T, Khargi K, M\u00fcller KM, Lemke B, M\u00fcgge A, Laczkovics A, et al. Histopathology of intraoperatively induced linear radiofrequency ablation lesions in patients with chronic atrial fibrillation. <i>Eur Heart J<\/i> 2005; 26: 1797\u20131803.","DOI":"10.1093\/eurheartj\/ehi255"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Khairy P, Chauvet P, Lehmann J, Lambert J, Macle L, Tanguay JF, et al. Lower incidence of thrombus formation with cryoenergy versus radiofrequency catheter ablation. <i>Circulation<\/i> 2003; 107: 2045\u20132050.","DOI":"10.1161\/01.CIR.0000058706.82623.A1"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24. Dubuc M, Roy D, Thibault B, Ducharme A, Tardif JC, Villemaire C, et al. Transvenous catheter ice mapping and cryoablation of the atrioventricular node in dogs. <i>Pacing Clin Electrophysiol<\/i> 1999; 22: 1488\u20131498.","DOI":"10.1111\/j.1540-8159.1999.tb00353.x"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25. Oswald H, Gardiwal A, Lissel C, Yu H, Klein G. Difference in humoral biomarkers for myocardial injury and inflammation in radiofrequency ablation versus cryoablation. <i>Pacing Clin Electrophysiol<\/i> 2007; 30: 885\u2013890.","DOI":"10.1111\/j.1540-8159.2007.00776.x"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26. Hern\u00e1ndez-Romero D, Mar\u00edn F, Rold\u00e1n V, Pe\u00f1afiel P, Vilchez JA, Orenes-Pi\u00f1ero E, et al. Comparative determination and monitoring of biomarkers of necrosis and myocardial remodeling between radiofrequency ablation and cryoablation. <i>Pacing Clin Electrophysiol<\/i> 2013; 36: 31\u201336.","DOI":"10.1111\/pace.12017"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27. Ciconte G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, Mugnai G, et al. Single 3-minute freeze for second-generation cryoballoon ablation: One-year follow-up after pulmonary vein isolation. <i>Heart Rhythm<\/i> 2015; 12: 673\u2013680.","DOI":"10.1016\/j.hrthm.2014.12.026"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28. Takami M, Lehmann HI, Misiri J, Parker KD, Sarmiento RI, Johnson SB, et al. The impact of freezing time and balloon size on the thermodynamics and isolation efficacy during pulmonary vein isolation using the 2nd generation cryoballoon. <i>Circ Arrhythm Electrophysiol<\/i> 2015; 8: 836\u2013845.","DOI":"10.1161\/CIRCEP.115.002725"}],"container-title":["Circulation Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/80\/2\/80_CJ-15-1051\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,24]],"date-time":"2017-06-24T01:00:12Z","timestamp":1498266012000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/80\/2\/80_CJ-15-1051\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016]]},"references-count":28,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1253\/circj.cj-15-1051","relation":{},"ISSN":["1346-9843","1347-4820"],"issn-type":[{"value":"1346-9843","type":"print"},{"value":"1347-4820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016]]}}}