{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T18:47:10Z","timestamp":1787510830793,"version":"build-2736575974"},"reference-count":26,"publisher":"Japanese Circulation Society","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Circ J"],"published-print":{"date-parts":[[2018]]},"DOI":"10.1253\/circj.cj-17-0463","type":"journal-article","created":{"date-parts":[[2017,8,30]],"date-time":"2017-08-30T18:09:08Z","timestamp":1504116548000},"page":"396-402","source":"Crossref","is-referenced-by-count":6,"title":["Clinical Implication of Transaortic Mitral Pannus Removal During Repeat Cardiac Surgery for Patients With Mechanical Mitral Valve"],"prefix":"10.1253","volume":"82","author":[{"given":"Byungjoon","family":"Park","sequence":"first","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiick","family":"Sung","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pyo Won","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"330","reference":[{"key":"1","unstructured":"1. Cho YH, Jeong DS, Park PW, Park KH, Sung K, Kim WS, et al. Serial changes of hemodynamic performance with Medtronic Hall valve in aortic position. <i>Ann Thorac Surg<\/i> 2011; 91: 424\u2013431."},{"key":"2","unstructured":"2. Jeong DS, Park PW, Sung K, Park SW, Lee SC, Kim WS, et al. Long-term hemodynamic performance of bileaflet prostheses versus tilting-disc prostheses in the aortic position. <i>Int J Cardiol<\/i> 2013; 166: 681\u2013687."},{"key":"3","unstructured":"3. Jeong DS, Park PW, Sung K, Kim WS, Lee YT. Determinants of late tricuspid regurgitation after aortic-mitral double valve replacement. <i>Am J Cardiol<\/i> 2017; 119: 1643\u20131649."},{"key":"4","unstructured":"4. Jeong DS, Park PW, Mwambu TP, Sung K, Kim WS, Lee YT, et al. Tricuspid reoperation after left-sided rheumatic valve operations. <i>Ann Thorac Surg<\/i> 2013; 95: 2007\u20132013."},{"key":"5","unstructured":"5. Chang HW, Jeong DS, Cho YH, Sung K, Kim WS, Lee YT, et al. Tricuspid valve replacement vs. repair in severe tricuspid regurgitation. <i>Circ J<\/i> 2017; 81: 330\u2013338."},{"key":"6","unstructured":"6. Park B, Park PW, Park CK. Transaortic chordae and pannus removal without redo mitral valve replacement in prosthetic mitral valve malfunction. <i>Eur J Cardiothorac Surg<\/i> 2011; 39: 1057\u20131058."},{"key":"7","unstructured":"7. Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP, Guyton RA, et al. 2014 AHA\/ACC guideline for the management of patients with valvular heart disease: Executive summary: A report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines. <i>Circulation<\/i> 2014; 129: 2440\u20132492."},{"key":"8","unstructured":"8. Akins CW, Miller DC, Turina MI, Kouchoukos NT, Blackstone EH, Grunkemeier GL, et al. Guidelines for reporting mortality and morbidity after cardiac valve interventions. <i>J Thorac Cardiovasc Surg<\/i> 2008; 135: 732\u2013738."},{"key":"9","unstructured":"9. Rizzoli G, Guglielmi C, Toscano G, Pistorio V, Vendramin I, Bottio T, et al. Reoperations for acute prosthetic thrombosis and pannus: An assessment of rates, relationship and risk. <i>Eur J Cardiothorac Surg<\/i> 1999; 16: 74\u201380."},{"key":"10","unstructured":"10. Ellensen VS, Andersen KS, Vitale N, Davidsen ES, Segadal L, Haaverstad R. Acute obstruction by Pannus in patients with aortic medtronic-hall valves: 30 years of experience. <i>Ann Thorac Surg<\/i> 2013; 96: 2123\u20132128."},{"key":"11","unstructured":"11. Teshima H, Fukunaga S, Takaseya T, Tomoeda H, Akashi H, Aoyagi S. Obstruction of St. Jude medical valves in the aortic position: Plasma transforming growth factor type beta 1 in patients with pannus overgrowth. <i>Artif Organs<\/i> 2010; 34: 210\u2013215."},{"key":"12","unstructured":"12. Song H, Kim MJ, Chung CH, Choo SJ, Song MG, Song JM, et al. Factors associated with development of late significant tricuspid regurgitation after successful left-sided valve surgery. <i>Heart<\/i> 2009; 95: 931\u2013936."},{"key":"13","unstructured":"13. Kim JH, Kim TY, Choi JB, Kuh JH. Haemodynamic improvement of older, previously replaced mechanical mitral valves by removal of the subvalvular pannus in redo cardiac surgery. <i>Interact Cardiovasc Thorac Surg<\/i> 2017; 24: 148\u2013149."},{"key":"14","unstructured":"14. Dreyfus GD, Corbi PJ, Chan KM, Bahrami T. Secondary tricuspid regurgitation or dilatation: Which should be the criteria for surgical repair? <i>Ann Thorac Surg<\/i> 2005; 79: 127\u2013132."},{"key":"15","unstructured":"15. Benedetto U, Melina G, Angeloni E, Refice S, Roscitano A, Comito C, et al. Prophylactic tricuspid annuloplasty in patients with dilated tricuspid annulus undergoing mitral valve surgery. <i>J Thorac Cardiovasc Surg<\/i> 2012; 143: 632\u2013638."},{"key":"16","unstructured":"16. Chikwe J, Itagaki S, Anyanwu A, Adams DH. Impact of concomitant tricuspid annuloplasty on tricuspid regurgitation, right ventricular function, and pulmonary artery hypertension after repair of mitral valve prolapse. <i>J Am Coll Cardiol<\/i> 2015; 65: 1931\u20131938."},{"key":"17","unstructured":"17. Lee H, Sung K, Kim WS, Lee YT, Park SJ, Carriere KC, et al. Clinical and hemodynamic influences of prophylactic tricuspid annuloplasty in mechanical mitral valve replacement. <i>J Thorac Cardiovasc Surg<\/i> 2016; 151: 788\u2013795."},{"key":"18","unstructured":"18. Magne J, Mathieu P, Dumesnil JG, Tanne D, Dagenais F, Doyle D, et al. Impact of prosthesis-patient mismatch on survival after mitral valve replacement. <i>Circulation<\/i> 2007; 115: 1417\u20131425."},{"key":"19","unstructured":"19. Lam BK, Chan V, Hendry P, Ruel M, Masters R, Bedard P, et al. The impact of patient-prosthesis mismatch on late outcomes after mitral valve replacement. <i>J Thorac Cardiovasc Surg<\/i> 2007; 133: 1464\u20131473."},{"key":"20","unstructured":"20. Jamieson WR, Germann E, Ye J, Chan F, Cheung A, MacNab JS, et al. Effect of prosthesis-patient mismatch on long-term survival with mitral valve replacement: Assessment to 15 years. <i>Ann Thorac Surg<\/i> 2009; 87: 1135\u20131141; discussion 1142."},{"key":"21","unstructured":"21. Angeloni E, Melina G, Benedetto U, Roscitano A, Refice S, Quarto C, et al. Impact of prosthesis-patient mismatch on tricuspid valve regurgitation and pulmonary hypertension following mitral valve replacement. <i>Int J Cardiol<\/i> 2013; 168: 4150\u20134154."},{"key":"22","unstructured":"22. Sato S, Fujita T, Shimahara Y, Hata H, Kobayashi J. Impact of prosthesis-patient mismatch on late recurrence of atrial fibrillation after cryomaze procedure with mitral valve replacement. <i>Circ J<\/i> 2014; 78: 1908\u20131914."},{"key":"23","unstructured":"23. Lee S, Lee S, Pak E, Hong M, Kim J, Kim H, et al. Real-time 3D TEE for diagnosis of subvalvular pannus formation in mechanical aortic valves. <i>JACC Cardiovasc Imaging<\/i> 2015; 12: 1461\u20131464."},{"key":"24","unstructured":"24. Teshima H, Aoyagi S, Ueda T, Takagi K, Shojima T, Tanaka H. Evaluation of advancing the standard valve dysfunction by multidetector-row CT. <i>J Artif Org<\/i> 2014; 17: 162\u2013168."},{"key":"25","unstructured":"25. Ueda T, Teshima H, Fukunaga S, Aoyagi S, Tanaka H. Evaluation of prosthetic valve obstruction on electrocardiographically gated multidetector-row computerized tomography. <i>Circ J<\/i> 2013; 77: 418\u2013423."},{"key":"26","unstructured":"26. Suh YJ, Chang B, Im DJ, Kim YJ, Hong YJ, Hong G, et al. Assessment of mitral annuloplasty ring by cardiac computed tomography: Correlation with echocardigraphic parameters and comparision between two different ring types. <i>J Thorac Cardiovasc Surg<\/i> 2015; 150: 1082\u20131090."}],"container-title":["Circulation Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/82\/2\/82_CJ-17-0463\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,1,26]],"date-time":"2018-01-26T22:55:55Z","timestamp":1517007355000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/82\/2\/82_CJ-17-0463\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1253\/circj.cj-17-0463","relation":{},"ISSN":["1346-9843","1347-4820"],"issn-type":[{"value":"1346-9843","type":"print"},{"value":"1347-4820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018]]}}}