{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T18:36:52Z","timestamp":1768415812105,"version":"3.49.0"},"reference-count":13,"publisher":"Japanese Circulation Society","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Circ J"],"published-print":{"date-parts":[[2018]]},"DOI":"10.1253\/circj.cj-17-0537","type":"journal-article","created":{"date-parts":[[2017,8,24]],"date-time":"2017-08-24T18:07:52Z","timestamp":1503598072000},"page":"176-182","source":"Crossref","is-referenced-by-count":4,"title":["Morphological Changes and Device Migration After Stent Graft Insertion\u3000\u2015 Clinical Application of an Image-Based Modeling System and Analysis With Geometric Parameters \u2015"],"prefix":"10.1253","volume":"82","author":[{"given":"Youkou","family":"Nemoto","sequence":"first","affiliation":[{"name":"Division of Vascular Surgery, Department of Surgery, Graduate School of Medicine, The University of Tokyo"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katsuyuki","family":"Hoshina","sequence":"additional","affiliation":[{"name":"Division of Vascular Surgery, Department of Surgery, Graduate School of Medicine, The University of Tokyo"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masaharu","family":"Kobayashi","sequence":"additional","affiliation":[{"name":"Interfaculty Initiative in Information Studies\/Institute of Industrial Science, The University of Tokyo"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masaru","family":"Kimura","sequence":"additional","affiliation":[{"name":"Division of Vascular Surgery, Department of Surgery, Graduate School of Medicine, The University of Tokyo"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sota","family":"Yamamoto","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Graduate School, Shibaura Institute of Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshiaki","family":"Watanabe","sequence":"additional","affiliation":[{"name":"Division of Vascular Surgery, Department of Surgery, Graduate School of Medicine, The University of Tokyo"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marie","family":"Ohshima","sequence":"additional","affiliation":[{"name":"Interfaculty Initiative in Information Studies\/Institute of Industrial Science, The University of Tokyo"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"330","reference":[{"key":"1","unstructured":"1. Greenhalgh RM, Brown LC, Kwong GP, Powell JT, Thompson SG; EVAR Trial Participants. Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR Trial 1), 30-day operative mortality results: Randomised controlled trial. <i>Lancet<\/i> 2004; 364: 843\u2013848."},{"key":"2","unstructured":"2. Prinssen M, Verhoeven EL, Buth J, Cuypers PW, van Sambeek MR, Balm R, et al. A randomized trial comparing conventional and endovascular repair of abdominal aortic aneurysms. <i>N Engl J Med<\/i> 2004; 351: 1607\u20131618."},{"key":"3","unstructured":"3. United Kingdom EVAR Trial Investigators, Greenhalgh RM, Brown LC, Powell JT, Thompson SG, Epstein D, Sculpher MJ. Endovascular versus open repair of abdominal aortic aneurysm. <i>N Engl J Med<\/i> 2010; 362: 1863\u20131871."},{"key":"4","unstructured":"4. De Bruin JL, Baas AF, Buth J, Prinssen M, Verhoeven ELG, Cuypers PWM, et al. Long-term outcome of open or endovascular repair of abdominal aortic aneurysm. <i>N Engl J Med<\/i> 2010; 362: 1881\u20131889."},{"key":"5","unstructured":"5. Lederle FA, Freischlag JA, Kyriakides TC, Matsumura JS, Padberg FT, Kohler TR, et al. Long-term comparison of endovascular and open repair of abdominal aortic aneurysm. <i>N Engl J Med<\/i> 2012; 367: 1988\u20131997."},{"key":"6","unstructured":"6. Schurink GWH, Aarts NJM, van Baalen JM, Kool LJS, van Bockel JH. Stent attachment site-related endoleakage after stent graft treatment: An in vitro study of the effects of graft size, stent type, and atherosclerotic wall changes. <i>J Vasc Surg<\/i> 1999; 30: 658\u2013667."},{"key":"7","unstructured":"7. Albertini JN, Kalliafas S, Travis S, Yusuf W, Macierewicz JA, Whitaker SC, et al. Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms. <i>Eur J Vasc Endovasc Surg<\/i> 2000; 19: 308\u2013312."},{"key":"8","unstructured":"8. Raghavan ML, Kratzberg JA, Golzarian J. Introduction to biomechanics related to endovascular repair of abdominal aortic aneurysm. <i>Tech Vasc Interventional Rad<\/i> 2005; 8: 50\u201355."},{"key":"9","unstructured":"9. Lederle FA, Freischlag JA, Kyriakides TC, Padberg FT, Matsumura JS, Kohler TR, et al. Outcomes following endovascular vs open repair of abdominal aortic aneurysm: A randomized trial. <i>JAMA<\/i> 2009; 302: 1535\u20131542."},{"key":"10","unstructured":"10. Ihara T, Komori K, Banno H, Kodama A, Yamamoto K. Relationship between the distal migration and length of the distal landing zone after endovascular aneurysm repair (EVAR). <i>Surg Today<\/i> 2016; 46: 56\u201361."},{"key":"11","unstructured":"11. Kobayashi M, Hoshina K, Yamamoto S, Nemoto Y, Akai T, Shigematsu K, et al. Development of an image-based modeling system to investigate evolutional geometric changes of a stent graft in an abdominal aortic aneurysm. <i>Circ J<\/i> 2015; 79: 1534\u20131541."},{"key":"12","unstructured":"12. Hoshina K, Akai T, Takayama T, Kato M, Nakazawa T, Okamoto H, et al. Outcomes and morphologic changes after endovascular repair for abdominal aortic aneurysms with a severely angulated neck: A device-specific analysis. <i>Circ J<\/i> 2013; 77: 1996\u20132002."},{"key":"13","unstructured":"13. Abbruzzese TA, Kwolek CJ, Brewster DC, Chung TK, Kang J, Conrad MF, et al. Outcomes following endovascular abdominal aortic aneurysm repair (EVAR): An anatomic and device-specific analysis. <i>J Vasc Surg<\/i> 2008; 48: 19\u201328."}],"container-title":["Circulation Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/82\/1\/82_CJ-17-0537\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,12,29]],"date-time":"2017-12-29T22:55:54Z","timestamp":1514588154000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/82\/1\/82_CJ-17-0537\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"references-count":13,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1253\/circj.cj-17-0537","relation":{},"ISSN":["1346-9843","1347-4820"],"issn-type":[{"value":"1346-9843","type":"print"},{"value":"1347-4820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018]]}}}