{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:49:05Z","timestamp":1787021345165,"version":"build-2736575974"},"reference-count":15,"publisher":"Japanese Circulation Society","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Circ J"],"published-print":{"date-parts":[[2018,5,25]]},"DOI":"10.1253\/circj.cj-17-1001","type":"journal-article","created":{"date-parts":[[2018,4,10]],"date-time":"2018-04-10T18:15:28Z","timestamp":1523384128000},"page":"1546-1551","source":"Crossref","is-referenced-by-count":8,"title":["Safety and Efficacy of Subcutaneous Cardioverter Defibrillator in Patients at High Risk of Sudden Cardiac Death\u3000\u2015 Primary Japanese Experience \u2015"],"prefix":"10.1253","volume":"82","author":[{"given":"Shingo","family":"Sasaki","sequence":"first","affiliation":[{"name":"Department of Advanced Management of Cardiac Arrhythmias, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hirofumi","family":"Tomita","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuo","family":"Tsurugi","sequence":"additional","affiliation":[{"name":"Advanced Arrhythmia Therapeutic Branch, Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuji","family":"Ishida","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshihiro","family":"Shoji","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kimitaka","family":"Nishizaki","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takahiko","family":"Kinjo","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomohide","family":"Endo","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fumie","family":"Nishizaki","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenji","family":"Hanada","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenichi","family":"Sasaki","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daisuke","family":"Horiuchi","sequence":"additional","affiliation":[{"name":"Department of Advanced Management of Cardiac Arrhythmias, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masaomi","family":"Kimura","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takumi","family":"Higuma","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hirosaki University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideharu","family":"Okamatsu","sequence":"additional","affiliation":[{"name":"Advanced Arrhythmia Therapeutic Branch, Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasuaki","family":"Tanaka","sequence":"additional","affiliation":[{"name":"Advanced Arrhythmia Therapeutic Branch, Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junjiroh","family":"Koyama","sequence":"additional","affiliation":[{"name":"Advanced Arrhythmia Therapeutic Branch, Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ken","family":"Okumura","sequence":"additional","affiliation":[{"name":"Advanced Arrhythmia Therapeutic Branch, Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"330","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Bardy GH, Smith WM, Hood MA, Crozier IG, Melton IC, Jordaens L, et al. An entirely subcutaneous implantable cardioverter-defibrillator. <i>N Engl J Med<\/i> 2010; 363: 36\u201344.","DOI":"10.1056\/NEJMoa0909545"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Lambiase PD, Barr C, Theuns DA, Knops R, Neuzil P, Johansen JB, et al. Worldwide experience with a totally subcutaneous implantable defibrillator: Early results from the EFFORTLESS S-ICD Registry. <i>Eur Heart J<\/i> 2014; 35: 1657\u20131665.","DOI":"10.1093\/eurheartj\/ehu112"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Burke MC, Gold MR, Knight BP, Barr CS, Theuns DA, Boersma LV, et al. Safety and efficacy of the totally subcutaneous implantable defibrillator: 2-year results from a pooled analysis of the IDE study and EFFORTLESS registry. <i>J Am Coll Cardiol<\/i> 2015; 65: 1605\u20131615.","DOI":"10.1016\/j.jacc.2015.02.047"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Boersma L, Barr C, Knops R, Theuns D, Eckardt L, Neuzil P, et al. Implant and midterm outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry: The EFFORTLESS Study. <i>J Am Coll Cardiol<\/i> 2017; 70: 830\u2013841.","DOI":"10.1016\/j.jacc.2017.06.040"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Nishii N, Tachibana M, Morimoto Y, Kawada S, Miyoshi A, Sugiyama H, et al. Initial experience with the subcutaneous implantable cardioverter-defibrillator in a single Japanese center. <i>J Arrhythm<\/i> 2017; 33: 338\u2013341.","DOI":"10.1016\/j.joa.2017.02.004"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Knops RE, Olde Nordkamp LR, de Groot JR, Wilde AA. Two-incision technique for implantation of the subcutaneous implantable cardioverter-defibrillator. <i>Heart Rhythm<\/i> 2013; 10: 1240\u20131243.","DOI":"10.1016\/j.hrthm.2013.05.016"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Ferrari P, Giofr\u00e8 F, Filippo P. Intermuscular pocket for subcutaneous implantable cardioverter defibrillator: Single-center experience. <i>J Arrhythm<\/i> 2016; 32: 223\u2013226.","DOI":"10.1016\/j.joa.2016.01.005"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. JCS Joint Working Group. Guidelines for non-pharmacotherapy of cardiac arrhythmias (JCS 2011): Digest version. <i>Circ J<\/i> 2013; 77: 249\u2013274.","DOI":"10.1253\/circj.CJ-66-0054"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Weiss R, Knight BP, Gold MR, Leon AR, Herre JM, Hood M, et al. Safety and efficacy of a totally subcutaneous implantable-cardioverter defibrillator. <i>Circulation<\/i> 2013; 128: 944\u2013953.","DOI":"10.1161\/CIRCULATIONAHA.113.003042"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Gold MR, Aasbo JD, El-Chami MF, Niebauer M, Herre J, Prutkin JM, et al. Subcutaneous implantable cardioverter-defibrillator Post-Approval Study: Clinical characteristics and perioperative results. <i>Heart Rhythm<\/i> 2017; 14: 1456\u20131463.","DOI":"10.1016\/j.hrthm.2017.05.016"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Jarman JW, Todd DM. United Kingdom national experience of entirely subcutaneous implantable cardioverter defibrillator technology: Important lessons to learn. <i>Europace<\/i> 2013; 15: 1158\u20131165.","DOI":"10.1093\/europace\/eut016"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Olde Nordkamp LR, Dabiri Abkenari L, Boersma LV, Maass AH, de Groot JR, van Oostrom AJ, et al. The entirely subcutaneous implantable cardioverter-defibrillator: Initial clinical experience in a large Dutch cohort. <i>J Am Coll Cardiol<\/i> 2012; 60: 1933\u20131939.","DOI":"10.1016\/j.jacc.2012.06.053"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Aydin A, Hartel F, Schl\u00fcter M, Butter C, K\u00f6be J, Seifert M, et al. Shock efficacy of subcutaneous implantable cardioverter-defibrillator for prevention of sudden cardiac death: Initial multicenter experience. <i>Circ Arrhythm Electrophysiol<\/i> 2012; 5: 913\u2013919.","DOI":"10.1161\/CIRCEP.112.973339"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. K\u00f6be J, Reinke F, Meyer C, Shin DI, Martens E, K\u00e4\u00e4b S, et al. Implantation and follow-up of totally subcutaneous versus conventional implantable cardioverter-defibrillators: A multicenter case-control study. <i>Heart Rhythm<\/i> 2013; 10: 29\u201336.","DOI":"10.1016\/j.hrthm.2012.09.126"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Olde Nordkamp LR, Brouwer TF, Barr C, Theuns DA, Boersma LV, Johansen JB, et al. Inappropriate shocks in the subcutaneous ICD: Incidence, predictors and management. <i>Int J Cardiol<\/i> 2015; 195: 126\u2013133.","DOI":"10.1016\/j.ijcard.2015.05.135"}],"container-title":["Circulation Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/82\/6\/82_CJ-17-1001\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,14]],"date-time":"2019-10-14T19:17:25Z","timestamp":1571080645000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/82\/6\/82_CJ-17-1001\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5,25]]},"references-count":15,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1253\/circj.cj-17-1001","relation":{},"ISSN":["1346-9843","1347-4820"],"issn-type":[{"value":"1346-9843","type":"print"},{"value":"1347-4820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,5,25]]}}}