{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T22:37:36Z","timestamp":1761863856533},"reference-count":24,"publisher":"Japanese Circulation Society","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Circ J"],"published-print":{"date-parts":[[2018,8,24]]},"DOI":"10.1253\/circj.cj-17-1376","type":"journal-article","created":{"date-parts":[[2018,7,4]],"date-time":"2018-07-04T22:27:21Z","timestamp":1530743241000},"page":"2317-2325","source":"Crossref","is-referenced-by-count":11,"title":["Inter-Technique Consistency and Prognostic Value of Intra-Procedural Angiographic and Echocardiographic Assessment of Aortic Regurgitation After Transcatheter Aortic Valve Implantation"],"prefix":"10.1253","volume":"82","author":[{"given":"Hiroki","family":"Tateishi","sequence":"first","affiliation":[{"name":"Division of Cardiology, Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yosuke","family":"Miyazaki","sequence":"additional","affiliation":[{"name":"Thoraxcenter, Erasmus Medical Centre"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takayuki","family":"Okamura","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammad","family":"Abdelghani","sequence":"additional","affiliation":[{"name":"Academic Medical Centre"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rodrigo","family":"Modolo","sequence":"additional","affiliation":[{"name":"Academic Medical Centre"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuaki","family":"Wada","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinichi","family":"Okuda","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayumi","family":"Omuro","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toru","family":"Ariyoshi","sequence":"additional","affiliation":[{"name":"Ultrasound Examination Center, Yamaguchi University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayano","family":"Fujii","sequence":"additional","affiliation":[{"name":"Division of Laboratory, Yamaguchi University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuro","family":"Oda","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatsuhiro","family":"Fujimura","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takuma","family":"Nanno","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akihito","family":"Mikamo","sequence":"additional","affiliation":[{"name":"Division of Surgery, Department of Clinical Science of Surgery, Yamaguchi University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Osama I.I.","family":"Soliman","sequence":"additional","affiliation":[{"name":"Thoraxcenter, Erasmus Medical Centre"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinobu","family":"Onuma","sequence":"additional","affiliation":[{"name":"Thoraxcenter, Erasmus Medical Centre"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kimikazu","family":"Hamano","sequence":"additional","affiliation":[{"name":"Division of Surgery, Department of Clinical Science of Surgery, Yamaguchi University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masafumi","family":"Yano","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick W.","family":"Serruys","sequence":"additional","affiliation":[{"name":"International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"330","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lemos PA, Fraccaro C, et al. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: Meta-analysis and systematic review of literature. <i>J Am Coll Cardiol<\/i> 2013; 61: 1585\u20131595.","DOI":"10.1016\/j.jacc.2013.01.047"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Pibarot P, Hahn RT, Weissman NJ, Monaghan MJ. Assessment of paravalvular regurgitation following TAVR: A proposal of unifying grading scheme. <i>JACC Cardiovasc Imaging<\/i> 2015; 8: 340\u2013360.","DOI":"10.1016\/j.jcmg.2015.01.008"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Kodali S, Pibarot P, Douglas PS, Williams M, Xu K, Thourani V, et al. Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: Characterizing patients and impact on outcomes. <i>Eur Heart J<\/i> 2015; 36: 449\u2013456.","DOI":"10.1093\/eurheartj\/ehu384"},{"key":"4","unstructured":"4. Colli A, Besola L, Salizzoni S, Gregori D, Tarantini G, Agrifoglio M, et al. Does pre-existing aortic regurgitation protect from death in patients who develop paravalvular leak after TAVI? <i>Int J Cardiol<\/i> 2016; 233: 52\u201360."},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Sellers RD, Levy MJ, Amplatz K, Lillehei CW. Left retrograde cardioangiography in acquired cardiac disease: Technic, indications and interpretations in 700 cases. <i>Am J Cardiol<\/i> 1964; 14: 437\u2013447.","DOI":"10.1016\/0002-9149(64)90027-X"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Hahn RT, Pibarot P, Weissman NJ, Rodriguez L, Jaber WA. Assessment of paravalvular aortic regurgitation after transcatheter aortic valve replacement: Intra-core laboratory variability. <i>J Am Soc Echocardiogr<\/i> 2015; 28: 415\u2013422.","DOI":"10.1016\/j.echo.2015.01.007"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Abdelghani M, Ren B, Spitzer E, Tateishi H, Jonker H, Geleijnse ML, et al. A granular approach to improve reproducibility of the echocardiographic assessment of paravalvular regurgitation after TAVI. <i>Int J Cardiovasc Imaging<\/i> 2016; 32: 1519\u20131526.","DOI":"10.1007\/s10554-016-0947-4"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Abdelghani M, Soliman OI, Schultz C, Vahanian A, Serruys PW. Adjudicating paravalvular leaks of transcatheter aortic valves: A critical appraisal. <i>Eur Heart J<\/i> 2016; 37: 2627\u20132644.","DOI":"10.1093\/eurheartj\/ehw115"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Schultz CJ, Slots TL, Yong G, Aben JP, Van Mieghem N, Swaans M, et al. An objective and reproducible method for quantification of aortic regurgitation after TAVI. <i>EuroIntervention<\/i> 2014; 10: 355\u2013363.","DOI":"10.4244\/EIJY14M05_06"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Tateishi H, Campos CAM, Abdelghani M, Leite RS, Mangione JA, Bary L, et al. Video densitometric assessment of aortic regurgitation after transcatheter aortic valve implantation: Results from the Brazilian TAVI registry. <i>EuroIntervention<\/i> 2016; 11: 1409\u20131418.","DOI":"10.4244\/EIJV11I12A271"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Miyazaki Y, Abdelghani M, de Boer ES, Aben JP, van Sloun M, Suchecki T, et al. A novel synchronized diastolic injection method to reduce contrast volume during aortography for aortic regurgitation assessment: In-vitro experiment of a transcatheter heart valve model. <i>EuroIntervention<\/i> 2017; 13: 1288\u20131295.","DOI":"10.4244\/EIJ-D-17-00355"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Abdelghani M, Miyazaki Y, de Boer ES, Aben JP, van Sloun M, Suchecki T, et al. Videodensitometric quantification of paravalvular regurgitation of a transcatheter aortic valve: In vitro validation. <i>EuroIntervention<\/i> 2018; 13: 1527\u20131535.","DOI":"10.4244\/EIJ-D-17-00595"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Abdelghani M, Tateishi H, Miyazaki Y, Cavalcante R, Soliman OII, Tijssen JG, et al. Angiographic assessment of aortic regurgitation by video-densitometry in the setting of TAVI: Echocardiographic and clinical correlates. <i>Catheter Cardiovasc Interv<\/i> 2017; 90: 650\u2013659.","DOI":"10.1002\/ccd.26926"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Mihara H, Shibayama K, Jilaihawi H, Itabashi Y, Berdejo J, Utsunomiya H, et al. Assessment of post-procedural aortic regurgitation after TAVR. <i>JACC Cardiovasc Imaging<\/i> 2015; 8: 993\u20131003.","DOI":"10.1016\/j.jcmg.2015.02.029"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Zamorano JL, Badano LP, Bruce C, Chan KL, Gon\u00e7alves A, Hahn RT, et al. EAE\/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. <i>Eur Heart J<\/i> 2011; 32: 2189\u20132214.","DOI":"10.1093\/eurheartj\/ehr259"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Kappetein AP, Head SJ, Genereux P, Piazza N, van Mieghem NM, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document. <i>J Thorac Cardiovasc Surg<\/i> 2013; 145: 6\u201323.","DOI":"10.1016\/j.jtcvs.2012.09.002"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Tateishi H, Abdelghani M, Cavalcante R, Miyazaki Y, Campos CM, Collet C, et al. The interaction of de novo and pre-existing aortic regurgitation after TAVI: Insights from a new quantitative aortographic technique. <i>EuroIntervention<\/i> 2017; 13: 60\u201368.","DOI":"10.4244\/EIJ-D-16-00647"},{"key":"18","unstructured":"18. Campbell MJ, Swinscow TDV. Statistics at square one, 11th edition. Chichester, UK: Wiley-Blackwell\/BMJ Books, 2009."},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach. <i>Biometrics<\/i> 1988; 44: 837\u2013845.","DOI":"10.2307\/2531595"},{"key":"20","unstructured":"20. Abdelghani M, Tateishi H, Spitzer E, Tijssen JG, de Winter RJ, Soliman OII, et al. Echocardiographic and angiographic assessment of paravalvular regurgitation after TAVI: Optimizing inter-technique reproducibility. <i>Eur Heart J Cardiovasc Imaging<\/i> 2017; 18: 697\u2013706."},{"key":"21","doi-asserted-by":"crossref","unstructured":"21. Mol A, Rutten MC, Driessen NJ, Bouten CV, Zund G, Baaijens FP, et al. Autologous human tissue-engineered heart valves: Prospects for systemic application. <i>Circulation<\/i> 2006; 114(1 Suppl): I152\u2013I158.","DOI":"10.1161\/CIRCULATIONAHA.105.001123"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Schampaert S, Pennings KA, van de Molengraft MJ, Pijls NH, van de Vosse FN, Rutten MC. A mock circulation model for cardiovascular device evaluation. <i>Physiol Meas<\/i> 2014; 35: 687\u2013702.","DOI":"10.1088\/0967-3334\/35\/4\/687"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Tateishi H, Miyazaki Y, Okamura T, Modolo R, Abdelghani M, Soliman OII, et al. Role of computed tomography in planning the appropriate X-ray gantry for quantitative aortography of post-transcatheter aortic valve implantation regurgitation. <i>Circ J<\/i> 2018; 82: 1943\u20131950.","DOI":"10.1253\/circj.CJ-17-1375"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24. Abdelghani M, Soliman OII, Schultz C, Vahanian A, Serruys PW. Adjudicating paravalvular leaks of transcatheter aortic valves: A critical appraisal. <i>Eur Heart J<\/i> 2016; 37: 2627\u20132644.","DOI":"10.1093\/eurheartj\/ehw115"}],"container-title":["Circulation Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/82\/9\/82_CJ-17-1376\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,20]],"date-time":"2019-10-20T10:26:41Z","timestamp":1571567201000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/82\/9\/82_CJ-17-1376\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8,24]]},"references-count":24,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1253\/circj.cj-17-1376","relation":{},"ISSN":["1346-9843","1347-4820"],"issn-type":[{"value":"1346-9843","type":"print"},{"value":"1347-4820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,8,24]]}}}