{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,9,3]],"date-time":"2022-09-03T05:14:43Z","timestamp":1662182083559},"reference-count":29,"publisher":"Japanese Circulation Society","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Circ J"],"published-print":{"date-parts":[[2020,9,25]]},"DOI":"10.1253\/circj.cj-20-0499","type":"journal-article","created":{"date-parts":[[2020,9,4]],"date-time":"2020-09-04T22:05:44Z","timestamp":1599257144000},"page":"1818-1825","source":"Crossref","is-referenced-by-count":1,"title":["Hybrid Assessment of Myocardial Ischemia Using Stress-Only Nuclear Myocardial Perfusion Imaging and Rest Computed Tomography Perfusion Imaging"],"prefix":"10.1253","volume":"84","author":[{"given":"Yasuyuki","family":"Suzuki","sequence":"first","affiliation":[{"name":"Department of Cardiology, Nihon University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoya","family":"Matsumoto","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Nihon University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayano","family":"Makita","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Nihon University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tadashi","family":"Ashida","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Nihon University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keiichiro","family":"Kuronuma","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Nihon University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuo","family":"Amano","sequence":"additional","affiliation":[{"name":"Department of Radiology, Nihon University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shunichi","family":"Yoda","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Nihon University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuo","family":"Okumura","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Nihon University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"330","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Holly TA, Abbott BG, Al-Mallah M, Calnon DA, Cohen MC, DiFilippo FP, et al. Single photon-emission computed tomography: ASNC Imaging Guideline For Nuclear Cardiology Procedures. <i>J Nucl Cardiol<\/i> 2010; 17: 941\u2013973.","DOI":"10.1007\/s12350-010-9246-y"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Shaw LJ, Hendel RC, Heller GV, Borges-Neto S, Cerqueira M, Berman DS. Prognostic estimation of coronary artery disease risk with resting perfusion abnormalities and stress ischemia on myocardial perfusion SPECT. <i>J Nucl Cardiol Clin<\/i> 2008; 15: 762\u2013773.","DOI":"10.1007\/BF03007357"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Einstein AJ, Pascual TN, Mercuri M, Karthikeyan G, Vitola JV, Mahmarian JJ, et al. Current worldwide nuclear cardiology practices and radiation exposure: RESULTS from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS). <i>Eur Heart J<\/i> 2015; 36: 1689\u20131696.","DOI":"10.1093\/eurheartj\/ehv117"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Ueyama T, Takehana K, Maeba H, Iwasaka T. Prognostic value of normal stress-only technetium-99 m myocardial perfusion imaging protocol: Comparison with standard stress-rest protocol. <i>Circ J<\/i> 2012; 76: 2386\u20132391.","DOI":"10.1253\/circj.CJ-12-0081"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Ronan G, Wolk MJ, Bailey SR, Doherty JU, Douglas PS, Hendel RC, et al. ACCF\/AHA\/ASE\/ASNC\/HFSA\/HRS\/SCAI\/SCCT\/SCMR\/STS 2013 multimodality appropriate use criteria for the detection and risk assessment of stable ischemic heart disease: A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, American Heart Association, American Society of Echocardiography, American Society of Nuclear Cardiology, Heart Failure Society of America, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and Society of Thoracic Surgeons. <i>J Nucl Cardiol<\/i> 2014; 21: 192\u2013220.","DOI":"10.1007\/s12350-013-9841-9"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Gerber BL, Belge B, Legros GJ, Lim P, Poncelet A, Pasquet A, et al. Characterization of acute and chronic myocardial infarcts by multidetector computed tomography: Comparison with contrast-enhanced magnetic resonance. <i>Circulation<\/i> 2006; 113: 823\u2013833.","DOI":"10.1161\/CIRCULATIONAHA.104.529511"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Flotats A, Knuuti J, Gutberlet M, Marcassa C, Bengel FM, Kaufmann PA, et al. Hybrid cardiac imaging: SPECT\/CT and PET\/CT. A joint position statement by the European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC). <i>Eur J Nucl Med Mol Imaging<\/i> 2011; 38: 201\u2013212.","DOI":"10.1007\/s00259-010-1586-y"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Grani C, Benz DC, Schmied C, Vontobel J, Mikulicic F, Possner M, et al. Hybrid CCTA\/SPECT myocardial perfusion imaging findings in patients with anomalous origin of coronary arteries from the opposite sinus and suspected concomitant coronary artery disease. <i>J Nucl Cardiol<\/i> 2017; 24: 226\u2013234.","DOI":"10.1007\/s12350-015-0342-x"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Pazhenkottil AP, Nkoulou RN, Ghadri JR, Herzog BA, Buechel RR, Kuest SM, et al. Prognostic value of cardiac hybrid imaging integrating single-photon emission computed tomography with coronary computed tomography angiography. <i>Eur Heart J<\/i> 2011; 32: 1465\u20131471.","DOI":"10.1093\/eurheartj\/ehr047"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Rispler S, Aronson D, Abadi S, Roguin A, Engel A, Beyar R, et al. Integrated SPECT\/CT for assessment of haemodynamically significant coronary artery lesions in patients with acute coronary syndrome. <i>Eur J Nucl Med Mol Imaging<\/i> 2011; 38: 1917\u20131925.","DOI":"10.1007\/s00259-011-1856-3"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Schaap J, de Groot JA, Nieman K, Meijboom WB, Boekholdt SM, Kauling RM, et al. Added value of hybrid myocardial perfusion SPECT and CT coronary angiography in the diagnosis of coronary artery disease. <i>Eur Heart J Cardiovasc Imaging<\/i> 2014; 15: 1281\u20131288.","DOI":"10.1093\/ehjci\/jeu135"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Schaap J, de Groot JA, Nieman K, Meijboom WB, Boekholdt SM, Post MC, et al. Hybrid myocardial perfusion SPECT\/CT coronary angiography and invasive coronary angiography in patients with stable angina pectoris lead to similar treatment decisions. <i>Heart<\/i> 2013; 99: 188\u2013194.","DOI":"10.1136\/heartjnl-2012-302761"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. George RT, Arbab-Zadeh A, Cerci RJ, Vavere AL, Kitagawa K, Dewey M, et al. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320-MDCT: The CT angiography and perfusion methods of the CORE320 multicenter multinational diagnostic study. <i>Am J Roentgenol<\/i> 2011; 197: 829\u2013837.","DOI":"10.2214\/AJR.10.5689"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Leipsic J, Abbara S, Achenbach S, Cury R, Earls JP, Mancini GJ, et al. SCCT guidelines for the interpretation and reporting of coronary CT angiography: A report of the Society of Cardiovascular Computed Tomography Guidelines Committee. <i>J Cardiovasc Comput Tomogr<\/i> 2014; 8: 342\u2013358.","DOI":"10.1016\/j.jcct.2014.07.003"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Mehra VC, Valdiviezo C, Arbab-Zadeh A, Ko BS, Seneviratne SK, Cerci R, et al. A stepwise approach to the visual interpretation of CT-based myocardial perfusion. <i>J Cardiovasc Comput Tomogr<\/i> 2011; 5: 357\u2013369.","DOI":"10.1016\/j.jcct.2011.10.010"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Mendoza DD, Joshi SB, Weissman G, Taylor AJ, Weigold WG. Viability imaging by cardiac computed tomography. <i>J Cardiovasc Comput Tomogr<\/i> 2010; 4: 83\u201391.","DOI":"10.1016\/j.jcct.2010.01.019"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Berman DS, Kiat H, Friedman JD, Wang FP, van Train K, Matzer L, et al. Separate acquisition rest thallium-201\/stress technetium-99 m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: A clinical validation study. <i>J Am Coll Cardiol<\/i> 1993; 22: 1455\u20131464.","DOI":"10.1016\/0735-1097(93)90557-H"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Yoda S, Sato Y, Matsumoto N, Tani S, Takayama T, Nishina H, et al. Incremental value of regional wall motion analysis immediately after exercise for the detection of single-vessel coronary artery disease: Study by separate acquisition, dual-isotope ECG-gated single-photon emission computed tomography. <i>Circ J<\/i> 2005; 69: 301\u2013305.","DOI":"10.1253\/circj.69.301"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Berman DS, Kang X, Van Train KF, Lewin HC, Cohen I, Areeda J, et al. Comparative prognostic value of automatic quantitative analysis versus semiquantitative visual analysis of exercise myocardial perfusion single-photon emission computed tomography. <i>J Am Coll Cardiol<\/i> 1998; 32: 1987\u20131995.","DOI":"10.1016\/S0735-1097(98)00501-4"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Cousins C, Miller DL, Bernardi G, Rehani MM, Schofield P, Vano E, et al. ICRP Publication 120: Radiological protection in cardiology. <i>Ann ICRP<\/i> 2013; 42: 1\u2013125.","DOI":"10.1016\/j.icrp.2012.09.001"},{"key":"21","unstructured":"21. Cuocolo A, Pace L, Ricciardelli B, Chiariello M, Trimarco B, Salvatore M. Identification of viable myocardium in patients with chronic coronary artery disease: Comparison of thallium-201 scintigraphy with reinjection and technetium-99 m-methoxyisobutyl isonitrile. <i>J Nucl Med<\/i> 1992; 33: 505\u2013511."},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Bettencourt N, Ferreira ND, Leite D, Carvalho M, Ferreira Wda S, Schuster A, et al. CAD detection in patients with intermediate-high pre-test probability: Low-dose CT delayed enhancement detects ischemic myocardial scar with moderate accuracy but does not improve performance of a stress-rest CT perfusion protocol. <i>JACC Cardiovasc Imaging<\/i> 2013; 6: 1062\u20131071.","DOI":"10.1016\/j.jcmg.2013.04.013"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Yoshinaga K, Tomiyama Y, Suzuki E, Tamaki N. Myocardial blood flow quantification using positron-emission tomography: Analysis and practice in the clinical setting. <i>Circ J<\/i> 2013; 77: 1662\u20131671.","DOI":"10.1253\/circj.CJ-13-0235"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24. Henzlova MJ, Duvall WL, Einstein AJ, Travin MI, Verberne HJ. ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers. <i>J Nucl Cardiol<\/i> 2016; 23: 606\u2013639.","DOI":"10.1007\/s12350-015-0387-x"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25. Nakazato R, Berman DS, Hayes SW, Fish M, Padgett R, Xu Y, et al. Myocardial perfusion imaging with a solid-state camera: Simulation of a very low dose imaging protocol. <i>J Nucl Med<\/i> 2013; 54: 373\u2013379.","DOI":"10.2967\/jnumed.112.110601"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26. Perrin M, Djaballah W, Moulin F, Claudin M, Veran N, Imbert L, et al. Stress-first protocol for myocardial perfusion SPECT imaging with semiconductor cameras: High diagnostic performances with significant reduction in patient radiation doses. <i>Eur J Nucl Med Mol Imaging<\/i> 2015; 42: 1004\u20131011.","DOI":"10.1007\/s00259-015-3016-7"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27. Sharir T, Pinskiy M, Pardes A, Rochman A, Prokhorov V, Kovalski G, et al. Comparison of the diagnostic accuracies of very low stress-dose with standard-dose myocardial perfusion imaging: Automated quantification of one-day, stress-first SPECT using a CZT camera. <i>J Nucl Cardiol<\/i> 2016; 23: 11\u201320.","DOI":"10.1007\/s12350-015-0130-7"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28. Zafrir N, Bental T, Solodky A, Ben-Shlomo A, Mats I, Hassid Y, et al. Feasibility of myocardial perfusion imaging with half the radiation dose in obese patients using ordered-subset expectation maximization with resolution recovery software. <i>J Nucl Cardiol<\/i> 2013; 20: 111\u2013119.","DOI":"10.1007\/s12350-012-9650-6"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29. Mouden M, Timmer JR, Ottervanger JP, Reiffers S, Oostdijk AH, Knollema S, et al. Impact of a new ultrafast CZT SPECT camera for myocardial perfusion imaging: Fewer equivocal results and lower radiation dose. <i>Eur J Nucl Med Mol Imaging<\/i> 2012; 39: 1048\u20131055.","DOI":"10.1007\/s00259-012-2086-z"}],"container-title":["Circulation Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/84\/10\/84_CJ-20-0499\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,26]],"date-time":"2020-09-26T03:19:38Z","timestamp":1601090378000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/84\/10\/84_CJ-20-0499\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,25]]},"references-count":29,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1253\/circj.cj-20-0499","relation":{},"ISSN":["1346-9843","1347-4820"],"issn-type":[{"value":"1346-9843","type":"print"},{"value":"1347-4820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,25]]}}}