{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T07:46:40Z","timestamp":1791359200232,"version":"4.3.1"},"reference-count":34,"publisher":"Japanese Circulation Society","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Circ J"],"published-print":{"date-parts":[[2021,6,25]]},"DOI":"10.1253\/circj.cj-20-1084","type":"journal-article","created":{"date-parts":[[2021,2,26]],"date-time":"2021-02-26T22:06:29Z","timestamp":1614377189000},"page":"967-976","source":"Crossref","is-referenced-by-count":19,"title":["Transcatheter Aortic Valve Replacement in Patients With a Small Annulus\u3000\u2015 From the Japanese Nationwide Registry (J-TVT) \u2015"],"prefix":"10.1253","volume":"85","author":[{"given":"Kentaro","family":"Meguro","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Medicine, Kitasato University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiraku","family":"Kumamaru","sequence":"additional","affiliation":[{"name":"Department of Healthcare Quality Assessment, Graduate School of Medicine, the University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shun","family":"Kohsaka","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Keio University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuya","family":"Hashimoto","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Kitasato University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryota","family":"Kakizaki","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Kitasato University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tadashi","family":"Kitamura","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Kitasato University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideyuki","family":"Shimizu","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Keio University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junya","family":"Ako","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Kitasato University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"330","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. <i>N Engl J Med<\/i> 2010; 363: 1597\u20131607.","DOI":"10.1056\/NEJMoa1008232"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Leon MB, Smith CR, Mack MJ, Makkar RR, Svensson LG, Kodali SK, et al. Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. <i>N Engl J Med<\/i> 2016; 374: 1609\u20131620.","DOI":"10.1056\/NEJMoa1514616"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. S\u00f8ndergaard L, Steinbr\u00fcchel DA, Ihlemann N, Nissen H, Kjeldsen BJ, Petursson P, et al. Two-year outcomes in patients with severe aortic valve stenosis randomized to transcatheter versus surgical aortic valve replacement: The All-Comers Nordic Aortic Valve Intervention Randomized Clinical Trial. <i>Circ Cardiovasc Interv<\/i> 2016; 9: 1\u201310.","DOI":"10.1161\/CIRCINTERVENTIONS.115.003665"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Baumgartner H, Falk V, Bax JJ, De Bonis M, Hamm C, Holm PJ, et al. 2017 ESC\/EACTS Guidelines for the management of valvular heart disease. <i>Eur Heart J<\/i> 2017; 38: 2739\u20132786.","DOI":"10.1093\/eurheartj\/ehx391"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Popma JJ, Deeb GM, Yakubov SJ, Mumtaz M, Gada H, O\u2019Hair D, et al. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. <i>N Engl J Med<\/i> 2019; 380: 1706\u20131715.","DOI":"10.1056\/NEJMoa1816885"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Mack MJ, Leon MB, Thourani VH, Makkar R, Kodali SK, Russo M, et al. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. <i>N Engl J Med<\/i> 2019; 380: 1695\u20131705.","DOI":"10.1056\/NEJMoa1814052"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Handa N, Kumamaru H, Torikai K, Kohsaka S, Takayama M, Kobayashi J, et al. Learning curve for transcatheter aortic valve implantation under a controlled introduction system: Initial analysis of a Japanese Nationwide Registry. <i>Circ J<\/i> 2018; 82: 1951\u20131958.","DOI":"10.1253\/circj.CJ-18-0211"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Watanabe Y, Hayashida K, Takayama M, Mitsudo K, Nanto S, Takanashi S, et al. First direct comparison of clinical outcomes between European and Asian cohorts in transcatheter aortic valve implantation: The Massy study group vs. the PREVAIL JAPAN trial. <i>J Cardiol<\/i> 2015; 65: 112\u2013116.","DOI":"10.1016\/j.jjcc.2014.05.001"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Yoon SH, Ohno Y, Araki M, Barbanti M, Lin MS, Ahn JM, et al. Comparison of aortic root anatomy and calcification distribution between Asian and Caucasian patients who underwent transcatheter aortic valve implantation. <i>Am J Cardiol<\/i> 2015; 116: 1566\u20131573.","DOI":"10.1016\/j.amjcard.2015.08.021"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Meguro K, Kakizaki R, Hashimoto T, Yanagisawa T, Koitabashi T, Kitamura T, et al. Early safety and efficacy of Sapien 3 20 mm transcatheter heart valve implantation in small Japanese body size. <i>Heart Surg Forum<\/i> 2018; 21: E341\u2013E344.","DOI":"10.1532\/hsf.1918"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Puri R, Byrne J, Muller R, Baumbach H, Eltchaninoff H, Redwood S, et al. Transcatheter aortic valve implantation in patients with small aortic annuli using a 20 mm balloon-expanding valve. <i>Heart<\/i> 2017; 103: 148\u2013153.","DOI":"10.1136\/heartjnl-2016-309707"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Herrmann HC, Daneshvar SA, Fonarow GC, Stebbins A, Vemulapalli S, Desai ND, et al. Prosthesis\u2013patient mismatch in patients undergoing transcatheter aortic valve replacement: From the STS\/ACC TVT Registry. <i>J Am Coll Cardiol<\/i> 2018; 72: 2701\u20132711.","DOI":"10.1016\/j.jacc.2018.09.001"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Pibarot P, Weissman NJ, Stewart WJ, Hahn RT, Lindman BR, McAndrew T, et al. Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: A PARTNER trial cohort-a analysis. <i>J Am Coll Cardiol<\/i> 2014; 64: 1323\u20131334.","DOI":"10.1016\/j.jacc.2014.06.1195"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Mu\u00f1oz-Garc\u00eda AJ, Mu\u00f1oz-Garc\u00eda M, Carrasco-Chinchilla F, Molina-Mora MJ, Rodr\u00edguez-Bail\u00f3n I, Dom\u00ednguez-Franco AJ, et al. Incidence and clinical outcome of prosthesis-patient mismatch after transcatheter aortic valve implantation with the CoreValve prosthesis. <i>Int J Cardiol<\/i> 2013; 167: 1074\u20131076.","DOI":"10.1016\/j.ijcard.2012.10.062"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: Definition, clinical impact, and prevention. <i>Heart<\/i> 2006; 92: 1022\u20131029.","DOI":"10.1136\/hrt.2005.067363"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Reardon MJ, Van Mieghem NM, Popma JJ, Kleiman NS, Sondergaard L, Mumtaz M, et al. Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. <i>N Engl J Med<\/i> 2017; 376: 1321\u20131331.","DOI":"10.1056\/NEJMoa1700456"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Kodali SK, Williams MR, Smith CR, Svensson LG, Webb JG, Makkar RR, et al. Two-year outcomes after transcatheter or surgical aortic-valve replacement. <i>N Engl J Med<\/i> 2012; 366: 1686\u20131695.","DOI":"10.1056\/NEJMoa1200384"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Yashima F, Yamamoto M, Tanaka M, Yanagisawa R, Arai T, Shimizu H, et al. Transcatheter aortic valve implantation in patients with an extremely small native aortic annulus: The OCEAN-TAVI registry. <i>Int J Cardiol<\/i> 2017; 240: 126\u2013131.","DOI":"10.1016\/j.ijcard.2017.01.076"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Kappetein AP, Head SJ, G\u00e9n\u00e9reux P, Piazza N, Mieghem NM Van, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document. <i>Eur Heart J<\/i> 2012; 33: 2403\u20132418.","DOI":"10.1093\/eurheartj\/ehs255"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Kong WKF, van Rosendael PJ, van der Kley F, de Weger A, Kamperidis V, Regeer MV, et al. Impact of different iterations of devices and degree of aortic valve calcium on paravalvular regurgitation after transcatheter aortic valve implantation. <i>Am J Cardiol<\/i> 2016; 118: 567\u2013571.","DOI":"10.1016\/j.amjcard.2016.05.053"},{"key":"21","unstructured":"21. Wong DTL, Bertaso AG, Liew GYH, Thomson VS, Cunnington MS, Richardson JD, et al. Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve. <i>J Invasive Cardiol<\/i> 2013; 25: 190\u2013195."},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Freitas-Ferraz AB, Tirado-Conte G, Dagenais F, Ruel M, Al-Atassi T, Dumont E, et al. Aortic stenosis and small aortic annulus. <i>Circulation<\/i> 2019; 139: 2685\u20132702.","DOI":"10.1161\/CIRCULATIONAHA.118.038408"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Kodali S, Pibarot P, Douglas PS, Williams M, Xu K, Thourani V, et al. Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: Characterizing patients and impact on outcomes. <i>Eur Heart J<\/i> 2015; 36: 449\u2013456.","DOI":"10.1093\/eurheartj\/ehu384"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24. Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lemos PA, Fraccaro C, et al. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: Meta-analysis and systematic review of literature. <i>J Am Coll Cardiol<\/i> 2013; 61: 1585\u20131595.","DOI":"10.1016\/j.jacc.2013.01.047"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25. Samim M, Stella PR, Agostoni P, Kluin J, Ramjankhan F, Sieswerda G, et al. A prospective \u201coversizing\u201d strategy of the Edwards SAPIEN bioprosthesis: Results and impact on aortic regurgitation. <i>J Thorac Cardiovasc Surg<\/i> 2013; 145: 398\u2013405.","DOI":"10.1016\/j.jtcvs.2011.12.067"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26. Vavuranakis M, Kalogeras K, Lavda M, Kolokathis MA, Papaioannou T, Oikonomou E, et al. Correlation of CoreValve implantation \u2018true cover index\u2019 with short and mid-term aortic regurgitation: A novel index. <i>Int J Cardiol<\/i> 2016; 223: 482\u2013487.","DOI":"10.1016\/j.ijcard.2016.08.114"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27. Miyasaka M, Tada N, Taguri M, Kato S, Enta Y, Otomo T, et al. Incidence, predictors, and clinical impact of prosthesis-patient mismatch following transcatheter aortic valve replacement in Asian patients: The OCEAN-TAVI Registry. <i>JACC Cardiovasc Interv<\/i> 2018; 11: 771\u2013780.","DOI":"10.1016\/j.jcin.2018.01.273"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28. Mohty D, Mohty-Echahidi D, Malouf JF, Girard SE, Schaff HV, Grill DE, et al. Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude Medical mechanical prostheses in the aortic position. <i>Circulation<\/i> 2006; 113: 420\u2013426.","DOI":"10.1161\/CIRCULATIONAHA.105.546754"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29. Hellhammer K, Piayda K, Afzal S, Kleinebrecht L, Makosch M, Hennig I, et al. The latest evolution of the medtronic CoreValve System in the era of transcatheter aortic valve replacement. <i>JACC Cardiovasc Interv<\/i> 2018; 11: 2314\u20132322.","DOI":"10.1016\/j.jcin.2018.07.023"},{"key":"30","doi-asserted-by":"crossref","unstructured":"30. Kodali S, Thourani VH, White J, Malaisrie SC, Lim S, Greason KL, et al. Early clinical and echocardiographic outcomes after SAPIEN 3 transcatheter aortic valve replacement in inoperable, high-risk and intermediate-risk patients with aortic stenosis. <i>Eur Hear J<\/i> 2016; 37: 2252\u20132262.","DOI":"10.1093\/eurheartj\/ehw112"},{"key":"31","doi-asserted-by":"crossref","unstructured":"31. Abdel-Wahab M, Mehilli J, Frerker C, Neumann FJ, Kurz T, T\u00f6lg R, et al. Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: The CHOICE randomized clinical trial. <i>JAMA - J Am Med Assoc<\/i> 2014; 311: 1503\u20131514.","DOI":"10.1001\/jama.2014.3316"},{"key":"32","doi-asserted-by":"crossref","unstructured":"32. Abdel-Wahab M, Neumann FJ, Mehilli J, Frerker C, Richardt D, Landt M, et al. 1-year outcomes after transcatheter aortic valve replacement with balloon-expandable versus self-expandable valves: Results from the CHOICE randomized clinical trial. <i>J Am Coll Cardiol<\/i> 2015; 66: 791\u2013800.","DOI":"10.1016\/j.jacc.2015.06.026"},{"key":"33","doi-asserted-by":"crossref","unstructured":"33. Di Martino LFM, Vletter WB, Ren B, Schultz C, Van Mieghem NM, Soliman OII, et al. Prediction of paravalvular leakage after transcatheter aortic valve implantation. <i>Int J Cardiovasc Imaging<\/i> 2015; 31: 1461\u20131468.","DOI":"10.1007\/s10554-015-0703-1"},{"key":"34","doi-asserted-by":"crossref","unstructured":"34. Hahn RT, Pibarot P, Webb J, Rodes-Cabau J, Herrmann HC, Williams M, et al. Outcomes with post-dilation following transcatheter aortic valve replacement: The partner i trial (placement of aortic transcatheter valve). <i>JACC Cardiovasc Interv<\/i> 2014; 7: 781\u2013789.","DOI":"10.1016\/j.jcin.2014.02.013"}],"container-title":["Circulation Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/85\/7\/85_CJ-20-1084\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,26]],"date-time":"2021-06-26T03:55:24Z","timestamp":1624679724000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/85\/7\/85_CJ-20-1084\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,25]]},"references-count":34,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1253\/circj.cj-20-1084","relation":{},"ISSN":["1346-9843","1347-4820"],"issn-type":[{"value":"1346-9843","type":"print"},{"value":"1347-4820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,25]]}}}