{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T20:39:14Z","timestamp":1792096754278,"version":"4.4.0"},"reference-count":31,"publisher":"Japanese Circulation Society","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Circ J"],"published-print":{"date-parts":[[2025,8,25]]},"DOI":"10.1253\/circj.cj-24-1031","type":"journal-article","created":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T18:07:57Z","timestamp":1748369277000},"page":"1499-1509","source":"Crossref","is-referenced-by-count":5,"title":["Deep Learning-Based Fully Automated Aortic Valve Leaflets and Root Measurement From Computed Tomography Images\u3000\u2015 A Feasibility Study \u2015"],"prefix":"10.1253","volume":"89","author":[{"given":"Haruo","family":"Yamauchi","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, Graduate School of Medicine, The University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gakuto","family":"Aoyama","sequence":"additional","affiliation":[{"name":"Research and Development Center, Canon Medical Systems Corporation"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Tsukihara","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Graduate School of Medicine, The University of Tokyo"},{"name":"Medical Device Development and Regulation Research Center, Graduate School of Engineering, The University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenji","family":"Ino","sequence":"additional","affiliation":[{"name":"Radiology Center, The University of Tokyo Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoki","family":"Tomii","sequence":"additional","affiliation":[{"name":"Department of Precision Engineering, Graduate School of Engineering, The University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shu","family":"Takagi","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Graduate School of Engineering, The University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsuhiko","family":"Fujimoto","sequence":"additional","affiliation":[{"name":"Research and Development Center, Canon Medical Systems Corporation"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuya","family":"Sakaguchi","sequence":"additional","affiliation":[{"name":"Research and Development Center, Canon Medical Systems Corporation"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ichiro","family":"Sakuma","sequence":"additional","affiliation":[{"name":"Medical Device Development and Regulation Research Center, Graduate School of Engineering, The University of Tokyo"},{"name":"Department of Precision Engineering, Graduate School of Engineering, The University of Tokyo"},{"name":"Department of Bioengineering, Graduate School of Engineering, The University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minoru","family":"Ono","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Graduate School of Medicine, The University of Tokyo"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"330","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Thaden JJ, Nkomo VT, Enriquez-Sarano M. The global burden of aortic stenosis. <i>Prog Cardiovasc Dis<\/i> 2014; 56: 565\u2013571.","DOI":"10.1016\/j.pcad.2014.02.006"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Mack MJ, Leon MB, Thourani VH, Makkar R, Kodali SK, Russo M, et al.; PARTNER 3 Investigators. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. <i>N Engl J Med<\/i> 2019; 380: 1695\u20131705.","DOI":"10.1056\/NEJMoa1814052"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Popma JJ, Deeb GM, Yakubov SJ, Mumtaz M, Gada H, O\u2019Hair D, et al.; Evolut Low Risk Trial Investigators. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. <i>N Engl J Med<\/i> 2019; 380: 1706\u20131715.","DOI":"10.1056\/NEJMoa1816885"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Sugiyama Y, Moriyama N, Miyashita H, Yokoyama H, Ochiai T, Shishido K, et al. Long-term assessment of survival after transcatheter aortic valve implantation: Insights from the international transcatheter aortic valve implantation registry. <i>Circ J<\/i> 2024; 88: 462\u2013471.","DOI":"10.1253\/circj.CJ-23-0593"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Yokohama F, Takaya Y, Ichikawa K, Nakayama R, Miki T, Toda H, et al. Association between aortic valve calcification and severity of concomitant aortic regurgitation in patients with severe aortic stenosis. <i>Circ J<\/i> 2024; 88: 606\u2013611.","DOI":"10.1253\/circj.CJ-22-0746"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Komiya T. Aortic valve repair update. <i>Gen Thorac Cardiovasc Surg<\/i> 2015; 63: 309\u2013319.","DOI":"10.1007\/s11748-015-0523-1"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Akinseye OA, Pathak A, Ibebuogu UN. Aortic valve regurgitation: A comprehensive review. <i>Curr Probl Cardiol<\/i> 2018; 43: 315\u2013334.","DOI":"10.1016\/j.cpcardiol.2017.10.004"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Stamou SC, Williams ML, Gunn TM, Hagberg RC, Lobdell KW, Kouchoukos NT. Aortic root surgery in the United States: A report from the Society of Thoracic Surgeons database. <i>J Thorac Cardiovasc Surg<\/i> 2015; 149: 116\u2013122.e4.","DOI":"10.1016\/j.jtcvs.2014.05.042"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Arimura S, Seki M, Sasaki K, Takai H, Matsuhama M, Kunihara T, et al. A nationwide survey of aortic valve surgery in Japan: Current status of valve preservation in cases with aortic regurgitation. <i>Gen Thorac Cardiovasc Surg<\/i> 2017; 65: 429\u2013434.","DOI":"10.1007\/s11748-017-0795-8"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Sch\u00e4fers HJ, Bierbach B, Aicher D. A new approach to the assessment of aortic cusp geometry. <i>J Thorac Cardiovasc Surg<\/i> 2006; 132: 436\u2013438.","DOI":"10.1016\/j.jtcvs.2006.04.032"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Sch\u00e4fers HJ, Schmied W, Marom G, Aicher D. Cusp height in aortic valves. <i>J Thorac Cardiovasc Surg<\/i> 2013; 146: 269\u2013274.","DOI":"10.1016\/j.jtcvs.2012.06.053"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Blanke P, Weir-McCall JR, Achenbach S, Delgado V, Hausleiter J, Jilaihawi H, et al. Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR): An Expert Consensus Document of the Society of Cardiovascular Computed Tomography. <i>JACC Cardiovasc Imaging<\/i> 2019; 12: 1\u201324.","DOI":"10.1016\/j.jcmg.2018.12.003"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Izawa Y, Mori S, Tretter JT, Quintessenza JA, Toh H, Toba T, et al. Normative aortic valvar measurements in adults using cardiac computed tomography: A potential guide to further sophisticated aortic valve-sparing surgery. <i>Circ J<\/i> 2021; 85: 1059\u20131067.","DOI":"10.1253\/circj.CJ-20-0938"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Zheng Y, John M, Liao R, Boese J, Kirschstein U, Georgescu B, et al. Automatic aorta segmentation and valve landmark detection in C-arm CT: Application to aortic valve implantation. Springer: Berlin, 2010; 476\u2013483.","DOI":"10.1007\/978-3-642-15705-9_58"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Elattar MA, Wiegerinck EM, Planken RN, Van Bavel E, Van Assen HC, Baan J Jr, et al. Automatic segmentation of the aortic root in CT angiography of candidate patients for transcatheter aortic valve implantation. <i>Med Biol Eng Comput<\/i> 2014; 52: 611\u2013618.","DOI":"10.1007\/s11517-014-1165-7"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Astudillo P, Mortier P, Bosmans J, De Backer O, de Jaegere P, Iannaccone F, et al. Automatic detection of the aortic annular plane and coronary ostia from multidetector computed tomography. <i>J Interv Cardiol<\/i> 2020; 2020: 9843275.","DOI":"10.1155\/2020\/9843275"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Kr\u00fcger N, Meyer A, Tautz L, H\u00fcllebrand M, Wamala I, Pullig M, et al. Cascaded neural network-based CT image processing for aortic root analysis. <i>Int J Comput Assist Radiol Surg<\/i> 2022; 17: 507\u2013519.","DOI":"10.1007\/s11548-021-02554-3"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Saitta A, Sturla F, Gorla R, Oliva OA, Votta E, Bedogni F, et al. A CT-based deep learning system for automatic assessment of aortic root morphology for TAVI planning. <i>Comput Biol Med<\/i> 2023; 163: 107147.","DOI":"10.1016\/j.compbiomed.2023.107147"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Santal\u00f3-Corcoy M, Corbin D, Tastet O, Lesage F, Modine T, Asgar A, et al. TAVI-PREP: A deep learning-based tool for automated measurements extraction in TAVI planning. <i>Diagnostics (Basel)<\/i> 2023; 13: 3181.","DOI":"10.3390\/diagnostics13203181"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Aoyama G, Zhao L, Zhao S, Xue X, Zhong Y, Yamauchi H, et al. Automatic aortic valve cusps segmentation from CT images based on the cascading multiple deep neural networks. <i>J Imaging<\/i> 2022; 8: 11.","DOI":"10.3390\/jimaging8010011"},{"key":"21","unstructured":"21. US Food &amp; Drug Administration. 510(k) premarket notification. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfPMN\/pmn.cfm?ID=K203312 (accessed December 14, 2024)."},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Boodhwani M, de Kerchove L, Glineur D, Poncelet A, Rubay J, Astarci P, et al. Repair-oriented classification of aortic insufficiency: Impact on surgical techniques and clinical outcomes. <i>J Thorac Cardiovasc Surg<\/i> 2009; 137: 286\u2013294.","DOI":"10.1016\/j.jtcvs.2008.08.054"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. <i>Lancet<\/i> 1986; 1: 307\u2013310.","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24. Rouhollahi A, Willi JN, Haltmeier S, Mehrtash A, Straughan R, Javadikasgari H, et al. CardioVision: A fully automated deep learning package for medical image segmentation and reconstruction generating digital twins for patients with aortic stenosis. <i>Comput Med Imaging Graph<\/i> 2023; 109: 102289.","DOI":"10.1016\/j.compmedimag.2023.102289"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25. Fan B, Tomii N, Tsukihara H, Maeda E, Yamauchi H, Nawata K, et al. Attention-guided decoder in dilated residual network for accurate aortic valve segmentation in 3D CT scans. <i>In<\/i>: Liao, H, Balocco S, Wang G, Zhang F, Liu Y, Ding Z, et al, editors. Machine learning and medical engineering for cardiovascular health and intravascular imaging and computer assisted stenting. First International Workshop, MLMECH 2019, and 8<sup>th<\/sup> Joint International Workshop, CVII-STENT 2019, held in conjunction with MICCAI 2019, Shenzen, China, October 13, 2019, Proceedings. Springer: Cham, 2019; 121\u2013129.","DOI":"10.1007\/978-3-030-33327-0_15"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26. Pak DH, Caballero A, Sun W, Duncan JS. Efficient aortic valve multilabel segmentation using a spatial transformer network. <i>In<\/i>: Proceedings of 2020 IEEE 17th international symposium on biomedical imaging (ISBI) Apr 3 2020; 1738\u20131742. https:\/\/ieeexplore.ieee.org\/document\/9098378 (accessed April 2025).","DOI":"10.1109\/ISBI45749.2020.9098378"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27. Payer C, \u0160tern D, Bischof H, Urschler M. Integrating spatial configuration into heatmap regression based CNNs for landmark localization. <i>Med Image Anal<\/i> 2019; 54: 207\u2013219.","DOI":"10.1016\/j.media.2019.03.007"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28. Isensee F, Jaeger PF, Kohl SAA, Petersen J, Maier-Hein KH. nnU-Net: A self-configuring method for deep learning-based biomedical image segmentation. <i>Nat Methods<\/i> 2021; 18: 203\u2013211.","DOI":"10.1038\/s41592-020-01008-z"},{"key":"29","unstructured":"29. Edwards SAPIEN 3 Transcatheter Heart Valve System, SAPIEN 3 Transcatheter Heart Valve, Edwards Commander Delivery System. https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf14\/P140031S085D.pdf (accessed December 14, 2024)."},{"key":"30","unstructured":"30. Medtronic Evolut<sup>TM<\/sup> FX System, Evolut<sup>TM<\/sup> FX Transcatheter Aortic Valve, Evolut<sup>TM<\/sup> FX Delivery Catheter System, Evolut<sup>TM<\/sup> FX Loading System. https:\/\/www.medtronic.com\/content\/dam\/emanuals\/cardio\/M004015C001DOC1_RevD_view.pdf (accessed December 14, 2024)."},{"key":"31","doi-asserted-by":"crossref","unstructured":"31. Tamer S, Mastrobuoni S, van Dyck M, Navarra E, Bollen X, Poncelet A, et al. Free margin length and geometric height in aortic root dilatation and leaflet prolapse: implications for aortic valve repair surgery. <i>Eur J Cardiothorac Surg<\/i> 2020; 57: 124\u2013132.","DOI":"10.1093\/ejcts\/ezz132"}],"container-title":["Circulation Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/89\/9\/89_CJ-24-1031\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,30]],"date-time":"2025-08-30T03:25:19Z","timestamp":1756524319000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circj\/89\/9\/89_CJ-24-1031\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,25]]},"references-count":31,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1253\/circj.cj-24-1031","relation":{},"ISSN":["1346-9843","1347-4820"],"issn-type":[{"value":"1346-9843","type":"print"},{"value":"1347-4820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,25]]},"article-number":"CJ-24-1031"}}