{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T04:08:53Z","timestamp":1789186133277,"version":"build-2803163510"},"reference-count":27,"publisher":"Japanese Circulation Society","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Circ Rep"],"published-print":{"date-parts":[[2026,9,10]]},"DOI":"10.1253\/circrep.cr-26-0120","type":"journal-article","created":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T22:14:07Z","timestamp":1784067247000},"page":"1404-1411","source":"Crossref","is-referenced-by-count":0,"title":["Efficacy and Safety of a Novel Filtering Function to Reduce Radiation Exposure During Catheter Ablation for Atrial Fibrillation"],"prefix":"10.1253","volume":"8","author":[{"given":"Nobuhiro","family":"Suzuki","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Medicine, Akita University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidehiro","family":"Iwakawa","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Akita University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiharu","family":"Shinohara","sequence":"additional","affiliation":[{"name":"Central Radiology Division, Akita University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryosuke","family":"Kato","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Akita University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiyu","family":"Wakabayashi","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Akita University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryota","family":"Kaimori","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Akita University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ken","family":"Terata","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Akita University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Watanabe","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Akita University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"330","reference":[{"key":"1","doi-asserted-by":"publisher","unstructured":"1. Calkins H, Hindricks G, Cappato R, Kim YH, Saad EB, Aguinaga L, et al. 2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. <i>Heart Rhythm<\/i> 2017; 14: e275\u2013e444, doi:10.1016\/j.hrthm.2017.05.012.","DOI":"10.1016\/j.hrthm.2017.05.012"},{"key":"2","doi-asserted-by":"publisher","unstructured":"2. Iwasaki YK, Noda T, Akao M, Fujino T, Hirano T, Inoue K, et al. JCS\/JHRS 2024 Guideline focused update on management of cardiac arrhythmias. <i>Circ J<\/i> 2025; 89: 1012\u20131073, doi:10.1253\/circj.CJ-24-0073.","DOI":"10.1253\/circj.CJ-24-0073"},{"key":"3","doi-asserted-by":"publisher","unstructured":"3. Kitai T, Kohsaka S, Kato T, Kato E, Sato K, Teramoto K, et al.; Japanese Circulation Society and the Japanese Heart Failure Society Joint Working Group. JCS\/JHFS 2025 Guideline on diagnosis and treatment of heart failure. <i>Circ J<\/i> 2025; 89: 1278\u20131444, doi:10.1253\/circj.CJ-25-0002.","DOI":"10.1253\/circj.CJ-25-0002"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Razminia M, Manankil MF, Eryazici PL, Arrieta-Garcia C, Wang T, D\u2019Silva OJ, et al. Nonfluoroscopic catheter ablation of cardiac arrhythmias in adults: Feasibility, safety, and efficacy. <i>J Cardiovasc Electrophysiol<\/i> 2012; 23: 1078\u20131086, doi:10.1111\/j.1540-8167.2012. 02365.x.","DOI":"10.1111\/j.1540-8167.2012.02344.x"},{"key":"5","doi-asserted-by":"publisher","unstructured":"5. Ferguson JD, Helms A, Mangrum JM, Mahapatra S, Mason P, Bilgutay A, et al. Catheter ablation of atrial fibrillation without fluoroscopy using intracardiac echocardiography and electroanatomic mapping. <i>Circ Arrhythm Electrophysiol<\/i> 2009; 2: 611\u2013619, doi:10.1161\/CIRCEP.109.872093.","DOI":"10.1161\/CIRCEP.109.872093"},{"key":"6","doi-asserted-by":"publisher","unstructured":"6. Borota L, Patz A. SPOT region of interest imaging: A novel functionality aimed at X-ray dose reduction in neurointerventional procedures. <i>Radiat Prot Dosimetry<\/i> 2020; 188: 322\u2013331, doi:10.1093\/rpd\/ncz290.","DOI":"10.1093\/rpd\/ncz290"},{"key":"7","doi-asserted-by":"publisher","unstructured":"7. Yoshinaga M, Muramatsu T, Kondo Y, Miyazaki A, Fukushima T, Sobue Y, et al. Using a SPOT ROI function to minimize radiation during chronic total occlusion percutaneous coronary interventions. <i>JACC Case Rep<\/i> 2025; 30: 103526, doi:10.1016\/j.jaccas.2025.103526.","DOI":"10.1016\/j.jaccas.2025.103526"},{"key":"8","doi-asserted-by":"publisher","unstructured":"8. Tashiro H, Terata K, Kato R, Wakabayashi H, Iwakawa H, Watanabe H. Cubital vein access provides a practical alternative to internal jugular vein access for coronary sinus catheter placement. <i>J Arrhythm<\/i> 2024; 40: 991\u2013997, doi:10.1002\/joa3.13110.","DOI":"10.1002\/joa3.13110"},{"key":"9","doi-asserted-by":"publisher","unstructured":"9. Iwasa K, Okada M, Tanaka K, Hirao Y, Miyazaki N, Watanabe H, et al. Placement of the coronary sinus catheter via the right cubital vein during atrial fibrillation ablation. <i>Circ Rep<\/i> 2025; 7: 1181\u20131189, doi:10.1253\/circrep.CR-25-0187.","DOI":"10.1253\/circrep.CR-25-0187"},{"key":"10","doi-asserted-by":"publisher","unstructured":"10. Kumar S, Khatri M, Kumar S, Partab FNU, Manoj Kumar FNU, Neha FNU, et al. Comparative efficacy and safety profiles of high-power, short-duration and low-power, long-duration radiofrequency ablation in atrial fibrillation: A systematic review and meta-analysis. <i>J Innov Card Rhythm Manag<\/i> 2023; 14: 5514\u20135527, doi:10.19102\/icrm.2023.14072.","DOI":"10.19102\/icrm.2023.14072"},{"key":"11","doi-asserted-by":"publisher","unstructured":"11. Leo M, Pedersen M, Rajappan K, Ginks MR, Hunter RJ, Bowers R, et al. Power, lesion size index and oesophageal temperature alerts during atrial fibrillation ablation: A randomized study. <i>Circ Arrhythm Electrophysiol<\/i> 2020; 13: e008316, doi:10.1161\/CIRCEP.120.008316.","DOI":"10.1161\/CIRCEP.120.008316"},{"key":"12","doi-asserted-by":"publisher","unstructured":"12. Picano E, Va\u00f1\u00f3 E, Rehani MM, Cuocolo A, Mont L, Bodi V, et al. The appropriate and justified use of medical radiation in cardiovascular imaging: A position document of the ESC Associations of Cardiovascular Imaging, Percutaneous Cardiovascular Interventions and Electrophysiology. <i>Eur Heart J<\/i> 2014; 35: 665\u2013672, doi:10.1093\/eurheartj\/eht394.","DOI":"10.1093\/eurheartj\/eht394"},{"key":"13","doi-asserted-by":"publisher","unstructured":"13. Ciraj-Bjelac O, Rehani M, Minamoto A, Sim KH, Liew HB, Vano E. Radiation-induced eye lens changes and risk for cataract in interventional cardiology. <i>Cardiology<\/i> 2012; 123: 168\u2013171, doi:10.1159\/000342458.","DOI":"10.1159\/000342458"},{"key":"14","doi-asserted-by":"publisher","unstructured":"14. Roguin A, Goldstein J, Bar O. Brain tumours among interventional cardiologists: A cause for alarm? Report of four new cases from two cities and a review of the literature. <i>EuroIntervention<\/i> 2012; 7: 1081\u20131086, doi:10.4244\/EIJV7I9A172.","DOI":"10.4244\/EIJV7I9A172"},{"key":"15","doi-asserted-by":"publisher","unstructured":"15. Liu J, Chen S, Zhou Y, Zheng X, Meng R, Tan N, et al. Effect of cumulative radiation exposure from Coronary catheterization on lung cancer mortality. <i>BMC Cancer<\/i> 2023; 23: 757, doi:10.1186\/s12885-023-11231-4.","DOI":"10.1186\/s12885-023-11231-4"},{"key":"16","doi-asserted-by":"publisher","unstructured":"16. Reeves RR, Ang L, Bahadorani J, Naghi J, Dominguez A, Palakodeti V, et al. Invasive cardiologists are exposed to greater left sided cranial radiation: The BRAIN study (Brain Radiation Exposure and Attenuation During Invasive Cardiology Procedures). <i>JACC Cardiovasc Interv<\/i> 2015; 8: 1197\u20131206, doi:10.1016\/j.jcin.2015.03.027.","DOI":"10.1016\/j.jcin.2015.03.027"},{"key":"17","doi-asserted-by":"publisher","unstructured":"17. Roguin A, Goldstein J, Bar O, Goldstein JA. Brain and neck tumors among physicians performing interventional procedures. <i>Am J Cardiol<\/i> 2013; 111: 1368\u20131372, doi:10.1016\/j.amjcard.2012.12.060.","DOI":"10.1016\/j.amjcard.2012.12.060"},{"key":"18","doi-asserted-by":"publisher","unstructured":"18. Fiorilli PN, Goldsweig AM. Occupationally exposed: It is time to protect ourselves! <i>J Soc Cardiovasc Angiogr Interv<\/i> 2023; 2: 100610, doi:10.1016\/j.jscai.2023.100610.","DOI":"10.1016\/j.jscai.2023.100610"},{"key":"19","doi-asserted-by":"publisher","unstructured":"19. Gaita F, Guerra PG, Battaglia A, Anselmino M. The dream of near-zero X-rays ablation comes true. <i>Eur Heart J<\/i> 2016; 37: 2749\u20132755, doi:10.1093\/eurheartj\/ehw223.","DOI":"10.1093\/eurheartj\/ehw223"},{"key":"20","doi-asserted-by":"publisher","unstructured":"20. Shibuya Y, Kanda T, Minamiguchi H, Sakio T, Matsumura M, Hamanaka Y, et al. Impact of general anesthesia on catheter stability during pulmonary vein isolation of atrial fibrillation. <i>Circ Rep<\/i> 2025; 7: 750\u2013755, doi:10.1253\/circrep.CR-25-0035.","DOI":"10.1253\/circrep.CR-25-0035"},{"key":"21","doi-asserted-by":"publisher","unstructured":"21. Bulava A, Hanis J, Eisenberger M. Catheter ablation of atrial fibrillation using zero-fluoroscopy technique: A randomized trial. <i>Pacing Clin Electrophysiol<\/i> 2015; 38: 797\u2013806, doi:10.1111\/pace.12634.","DOI":"10.1111\/pace.12634"},{"key":"22","doi-asserted-by":"publisher","unstructured":"22. Casella M, Pelargonio G, Dello Russo A, Riva S, Bartoletti S, Santangeli P, et al. \u201cNear-zero\u201d fluoroscopic exposure in supraventricular arrhythmia ablation using the EnSite NavXTM mapping system: Personal experience and review of the literature. <i>J Interv Card Electrophysiol<\/i> 2011; 31: 109\u2013118, doi:10.1007\/s10840-011-9553-5.","DOI":"10.1007\/s10840-011-9553-5"},{"key":"23","doi-asserted-by":"publisher","unstructured":"23. Tzeis S, Gerstenfeld EP, Kalman J, Saad EB, Sepehri Shamloo A, Andrade JG, et al. 2024 European Heart Rhythm Association\/Heart Rhythm Society\/Asia Pacific Heart Rhythm Society\/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation. <i>Europace<\/i> 2024; 26: euae043, doi:10.1093\/europace\/euae043.","DOI":"10.1093\/europace\/euae043"},{"key":"24","doi-asserted-by":"publisher","unstructured":"24. Reddy VY, Anic A, Koruth J, Petru J, Funasako M, Minami K, et al. Pulsed field ablation in patients with persistent atrial fibrillation. <i>J Am Coll Cardiol<\/i> 2020; 76: 1068\u20131080, doi:10.1016\/j.jacc.2020.07.007.","DOI":"10.1016\/j.jacc.2020.07.007"},{"key":"25","doi-asserted-by":"publisher","unstructured":"25. Miyazaki S. Pulsed field ablation for atrial fibrillation in Japan: Current status and future perspectives. <i>Circ Rep<\/i> 2026; 8: 531\u2013536, doi:10.1253\/circrep.CR-25-0284.","DOI":"10.1253\/circrep.CR-25-0284"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26. Mori H, Kato R. Radiofrequency ablation for atrial fibrillation in the pulsed field era: Mechanisms, principles, and future roles. <i>Circ J<\/i> 2025, doi:10.1253\/circj.CJ-25-1158.","DOI":"10.1253\/circj.CJ-25-1158"},{"key":"27","doi-asserted-by":"publisher","unstructured":"27. Soubh N, Gronwald J, Haarmann H, Rasenack E, Bengel P, Schl\u00f6gl S, et al. Next-generation atrial fibrillation ablation: clinical performance of pulsed-field ablation and very high-power short-duration radiofrequency. <i>J Interv Card Electrophysiol<\/i> 2024; 67: 2067\u20132075, doi:10.1007\/s10840-024-01853-4.","DOI":"10.1007\/s10840-024-01853-4"}],"container-title":["Circulation Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circrep\/8\/9\/8_CR-26-0120\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T03:25:37Z","timestamp":1789183537000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/circrep\/8\/9\/8_CR-26-0120\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,10]]},"references-count":27,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1253\/circrep.cr-26-0120","relation":{},"ISSN":["2434-0790"],"issn-type":[{"value":"2434-0790","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,10]]},"article-number":"CR-26-0120"}}