{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,26]],"date-time":"2025-10-26T13:58:08Z","timestamp":1761487088984},"reference-count":55,"publisher":"Oxford University Press (OUP)","issue":"912","license":[{"start":{"date-parts":[[2003,12,1]],"date-time":"2003-12-01T00:00:00Z","timestamp":1070236800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2003,12,1]]},"abstract":"<jats:p>This paper describes the implementation of intensity modulated radiotherapy (IMRT) in a radiotherapy department. When preparing to set-up an IMRT programme, it is important to review departmental protocols with regard to immobilization, CT planning, treatment planning and verification. Any additional quality assurance steps also need to be fully understood. A new IMRT programme is most likely to be successful if it builds on established clinical experience with three-dimensional conformal radiotherapy (CRT). Training of radiographers, clinicians and physicists is critical, and both team-work and communication are vital to ensure a smooth transition from 3DCRT to IMRT delivery in the clinic.<\/jats:p>","DOI":"10.1259\/bjr\/19737738","type":"journal-article","created":{"date-parts":[[2004,1,7]],"date-time":"2004-01-07T19:27:39Z","timestamp":1073503659000},"page":"850-856","source":"Crossref","is-referenced-by-count":23,"title":["Implementation of IMRT in the radiotherapy department"],"prefix":"10.1093","volume":"76","author":[{"given":"H A","family":"McNair","sequence":"first","affiliation":[{"name":"Departments of Radiotherapy and"}]},{"given":"E J","family":"Adams","sequence":"additional","affiliation":[{"name":"Physics, Royal Marsden NHS Trust and Institute of Cancer Research, Downs Road, Sutton, Surrey SM2 5PT and Fulham Road, London, UK"}]},{"given":"C H","family":"Clark","sequence":"additional","affiliation":[{"name":"Physics, Royal Marsden NHS Trust and Institute of Cancer Research, Downs Road, Sutton, Surrey SM2 5PT and Fulham Road, London, UK"}]},{"given":"E A","family":"Miles","sequence":"additional","affiliation":[{"name":"Departments of Radiotherapy and"}]},{"given":"C M","family":"Nutting","sequence":"additional","affiliation":[{"name":"Departments of Radiotherapy and"}]}],"member":"286","published-online":{"date-parts":[[2014,1,28]]},"reference":[{"key":"2024050213310410700_R1","doi-asserted-by":"crossref","unstructured":"Hutton J, Maynard A. A nice challenge for health economics. Health Economics \u00a02000;9:89\u201393.","DOI":"10.1002\/(SICI)1099-1050(200003)9:2<89::AID-HEC504>3.0.CO;2-G"},{"key":"2024050213310410700_R2","doi-asserted-by":"crossref","unstructured":"Adams EJ, Nutting CM, Convery DJ, Cosgrove VP, Henk JM, Dearnaley DP, et al. Potential role of intensity-modulated radiotherapy in the treatment of tumors of the maxillary sinus. Int J Radiat Oncol Biol Phys \u00a02001;51:579\u201388.","DOI":"10.1016\/S0360-3016(01)01655-8"},{"key":"2024050213310410700_R3","doi-asserted-by":"crossref","unstructured":"De Meerleer GO, Vakaet LA, De Gersem WR, De Wagter C, De Naeyer B, De Neve W. Radiotherapy of prostate cancer with or without intensity modulated beams: a planning comparison. Int J Radiat Oncol Biol Phys \u00a02000;47:639\u201348.","DOI":"10.1016\/S0360-3016(00)00419-3"},{"key":"2024050213310410700_R4","doi-asserted-by":"crossref","unstructured":"Huang D, Xia P, Akazawa P, Akazawa C, Quivey JM, Verhey LJ, et al. Comparison of treatment plans using intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for paranasal sinus carcinoma. Int J Radiat Oncol Biol Phys \u00a02003;56:158\u201368.","DOI":"10.1016\/S0360-3016(03)00080-4"},{"key":"2024050213310410700_R5","doi-asserted-by":"crossref","unstructured":"Kam MK, Chau RM, Suen J, Choi PH, Teo PM. Intensity-modulated radiotherapy in nasopharyngeal carcinoma: dosimetric advantage over conventional plans and feasibility of dose escalation. Int J Radiat Oncol Biol Phys \u00a02003;56:145\u201357.","DOI":"10.1016\/S0360-3016(03)00075-0"},{"key":"2024050213310410700_R6","doi-asserted-by":"crossref","unstructured":"Nutting CM, Convery DJ, Cosgrove VP, Rowbottom C, Padhani AR, Webb S, et al. Reduction of small and large bowel irradiation using an optimized intensity-modulated pelvic radiotherapy technique in patients with prostate cancer. Int J Radiat Oncol Biol Phys \u00a02000;48:649\u201356.","DOI":"10.1016\/S0360-3016(00)00653-2"},{"key":"2024050213310410700_R7","doi-asserted-by":"crossref","unstructured":"Nutting CM, Bedford JL, Cosgrove VP, Tait DM, Dearnaley DP, Webb S. A comparison of conformal and intensity-modulated techniques for oesophageal radiotherapy. Radiother Oncol \u00a02001;61:157\u201363.","DOI":"10.1016\/S0167-8140(01)00438-8"},{"key":"2024050213310410700_R8","unstructured":"Institute of Physics, Engineering in Medicine, Royal College of Radiologists, The College of Radiographers. Development and implementation of conformal radiotherapy in the United Kingdom. 2002."},{"key":"2024050213310410700_R9","doi-asserted-by":"crossref","unstructured":"Intensity Modulated Radiation Therapy Collaborative Working Group. Intensity-modulated radiotherapy: current status and issues of interest. Int J Radiat Oncol Biol Phys \u00a02001;51:880\u2013914.","DOI":"10.1016\/S0360-3016(01)01749-7"},{"key":"2024050213310410700_R10","doi-asserted-by":"crossref","unstructured":"Saw CB, Ayyangar KM, Zhen W, Yoe-Sein M, Pillai S, Enke CA. Clinical implementation of intensity-modulated radiation therapy. Med Dosim \u00a02002;27:161\u20139.","DOI":"10.1016\/S0958-3947(02)00099-7"},{"key":"2024050213310410700_R11","doi-asserted-by":"crossref","unstructured":"Van Esch A, Bohsung J, Sorvari P, Tenhunen M, Paiusco M, Iori M, et al. Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: experience from five radiotherapy departments. Radiother Oncol \u00a02002;65:53\u201370.","DOI":"10.1016\/S0167-8140(02)00174-3"},{"key":"2024050213310410700_R12","doi-asserted-by":"crossref","unstructured":"Butler EB, Teh BS, Grant WH III, Uhl BM, Kuppersmith RB, Chiu JK, et al. Smart (simultaneous modulated accelerated radiation therapy) boost: a new accelerated fractionation schedule for the treatment of head and neck cancer with intensity modulated radiotherapy. Int J Radiat Oncol Biol Phys \u00a01999;45:21\u201332.","DOI":"10.1016\/S0360-3016(99)00101-7"},{"key":"2024050213310410700_R13","doi-asserted-by":"crossref","unstructured":"Mohan R, Wu Q, Manning M, Schmidt-Ullrich R. Radiobiological considerations in the design of fractionation strategies for intensity-modulated radiation therapy of head and neck cancers. Int J Radiat Oncol Biol Phys \u00a02000;46:619\u201330.","DOI":"10.1016\/S0360-3016(99)00438-1"},{"key":"2024050213310410700_R14","doi-asserted-by":"crossref","unstructured":"Nutting CM, Convery DJ, Cosgrove VP, Rowbottom C, Vini L, Harmer C, et al. Improvements in target coverage and reduced spinal cord irradiation using intensity-modulated radiotherapy (IMRT) in patients with carcinoma of the thyroid gland. Radiother Oncol \u00a02001;60:173\u201380.","DOI":"10.1016\/S0167-8140(01)00382-6"},{"key":"2024050213310410700_R15","unstructured":"Adams EJ, Convery DJ, Cosgrove VP, McNair HA, Staffurth J, Vaarkamp J, et al. Clinical implmentation of dynamic and step-and-shoot IMRT to treat prostate cancer with high risk of pelvic lymph node involvement. Radiother Oncol (In press)."},{"key":"2024050213310410700_R16","doi-asserted-by":"crossref","unstructured":"Clark CH, Mubata CD, Meehan CA, Bidmead AM, Staffurth J, Humphreys ME, et al. IMRT clinical implementation: prostate and pelvic node irradiation using Helios and a 120-leaf multileaf collimator. J Appl Clin Med Phys \u00a02002;3:273\u201384.","DOI":"10.1120\/jacmp.v3i4.2551"},{"key":"2024050213310410700_R17","doi-asserted-by":"crossref","unstructured":"van Herk M, Bruce A, Kroes AP, Shouman T, Touw A, Lebesque JV. Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. Int J Radiat Oncol Biol Phys \u00a01995;33:1311\u201320.","DOI":"10.1016\/0360-3016(95)00116-6"},{"key":"2024050213310410700_R18","doi-asserted-by":"crossref","unstructured":"Burton KE, Thomas SJ, Whitney D, Routsis DS, Benson RJ, Burnet NG. Accuracy of a relocatable stereotactic radiotherapy head frame evaluated by use of a depth helmet. Clin Oncol (R Coll Radiol) \u00a02002;14:31\u20139.","DOI":"10.1053\/clon.2001.0001"},{"key":"2024050213310410700_R19","doi-asserted-by":"crossref","unstructured":"Graham JD, Warrington AP, Gill SS, Brada M. A non-invasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging. Radiother Oncol \u00a01991;21:60\u20132.","DOI":"10.1016\/0167-8140(91)90342-E"},{"key":"2024050213310410700_R20","doi-asserted-by":"crossref","unstructured":"Rosenberg I, Alheit H, Beardmore C, Lee KS, Warrington AP, Brada M. Patient position reproducibility in fractionated stereotactic radiotherapy: an update after changing dental impression material. Radiother Oncol \u00a01999;50:239\u201340.","DOI":"10.1016\/S0167-8140(99)00002-X"},{"key":"2024050213310410700_R21","doi-asserted-by":"crossref","unstructured":"Yu CX, Jaffray DA, Wong JW. The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation. Phys Med Biol \u00a01998;43:91\u2013104.","DOI":"10.1088\/0031-9155\/43\/1\/006"},{"key":"2024050213310410700_R22","doi-asserted-by":"crossref","unstructured":"Bortfeld T, Jokivarsi K, Goitein M, Kung J, Jiang SB. Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. Phys Med Biol \u00a02002;47:2203\u201320.","DOI":"10.1088\/0031-9155\/47\/13\/302"},{"key":"2024050213310410700_R23","doi-asserted-by":"crossref","unstructured":"Jiang SB, Pope C, Al Jarrah KM, Kung JH, Bortfield T, Chen GTY. An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments. Phys Med Biol \u00a02003;48:1773\u201384.","DOI":"10.1088\/0031-9155\/48\/12\/307"},{"key":"2024050213310410700_R24","doi-asserted-by":"crossref","unstructured":"Melian E, Mageras GS, Fuks Z, Leibel SA, Niehaus A, Lorant H, et al. Variation in prostate position quantitation and implications for three-dimensional conformal treatment planning. Int J Radiat Oncol Biol Phys \u00a01997;38:73\u201381.","DOI":"10.1016\/S0360-3016(97)00221-6"},{"key":"2024050213310410700_R25","doi-asserted-by":"crossref","unstructured":"Padhani AR, Khoo VS, Suckling J, Husband JE, Leach MO, Dearnaley DP. Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI. Int J Radiat Oncol Biol Phys \u00a01999;44:525\u201333.","DOI":"10.1016\/S0360-3016(99)00040-1"},{"key":"2024050213310410700_R26","doi-asserted-by":"crossref","unstructured":"Roeske JC, Forman JD, Mesina CF, He T, Pelizzari CA, Fontenla E, et al. Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy. Int J Radiat Oncol Biol Phys \u00a01995;33:1321\u20139.","DOI":"10.1016\/0360-3016(95)00225-1"},{"key":"2024050213310410700_R27","doi-asserted-by":"crossref","unstructured":"Wachter S, Gerstner N, Dorner D, Goldner G, Colotto A, Wambersie A, et al. The influence of a rectal balloon tube as internal immobilization device on variations of volumes and dose-volume histograms during treatment course of conformal radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys \u00a02002;52:91\u2013100.","DOI":"10.1016\/S0360-3016(01)01821-1"},{"key":"2024050213310410700_R28","doi-asserted-by":"crossref","unstructured":"Wu J, Haycocks T, Alasti H, Ottewell G, Middlemiss N, Abdolell M, et al. Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers. Radiother Oncol \u00a02001;61:127\u201333.","DOI":"10.1016\/S0167-8140(01)00452-2"},{"key":"2024050213310410700_R29","doi-asserted-by":"crossref","unstructured":"Seppenwoolde Y, Shirato H, Kitamura K, Shimizu S, van Herk M, Lebesque JV, et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys \u00a02002;53:822\u201334.","DOI":"10.1016\/S0360-3016(02)02803-1"},{"key":"2024050213310410700_R30","doi-asserted-by":"crossref","unstructured":"Kim DJ, Murray BR, Halperin R, Roa WH. Held-breath self-gating technique for radiotherapy of non-small-cell lung cancer: a feasibility study. Int J Radiat Oncol Biol Phys \u00a02001;49:43\u20139.","DOI":"10.1016\/S0360-3016(00)01372-9"},{"key":"2024050213310410700_R31","doi-asserted-by":"crossref","unstructured":"Hanley J, Debois MM, Mah D, Mageras GS, Raben A, Rosenzweig K, et al. Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. Int J Radiat Oncol Biol Phys \u00a01999;45:603\u201311.","DOI":"10.1016\/S0360-3016(99)00154-6"},{"key":"2024050213310410700_R32","doi-asserted-by":"crossref","unstructured":"Wong JW, Sharpe MB, Jaffray DA, Kini VR, Robertson JM, Stromberg JS, et al. The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys \u00a01999;44:911\u20139.","DOI":"10.1016\/S0360-3016(99)00056-5"},{"key":"2024050213310410700_R33","doi-asserted-by":"crossref","unstructured":"Balter J, Sandler H, Lam K, Bree R, Lichter A, Ten Haken R. Measurement of prostate movement over the course of routine radiotherapy using implanted markers. Int J Radiat Oncol Phys \u00a01995;31:113\u20138.","DOI":"10.1016\/0360-3016(94)00382-U"},{"key":"2024050213310410700_R34","doi-asserted-by":"crossref","unstructured":"Crook JM, Raymond Y, Salhani D, Yang H, Esche B. Prostate motion during standard radiotherapy as assessed by fiducial markers. Radiother Oncol \u00a01995;37:35\u201342.","DOI":"10.1016\/0167-8140(95)01613-L"},{"key":"2024050213310410700_R35","doi-asserted-by":"crossref","unstructured":"Kitamura K, Shirato H, Shimizu S, Shinohara N, Harabayashi T, Shimizu T, et al. Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT). Radiother Oncol \u00a02002;62:275\u201381.","DOI":"10.1016\/S0167-8140(02)00017-8"},{"key":"2024050213310410700_R36","doi-asserted-by":"crossref","unstructured":"Pang G, Beachey DJ, O'Brien PF, Rowlands JA. Imaging of 1.0-mm-diameter radiopaque markers with megavoltage X-rays: an improved online imaging system. Int J Radiat Oncol Biol Phys \u00a02002;52:532\u20137.","DOI":"10.1016\/S0360-3016(01)02709-2"},{"key":"2024050213310410700_R37","doi-asserted-by":"crossref","unstructured":"Shimizu S, Shirato H, Kitamura K, Shinohara N, Harabayashi T, Tsukamoto T, et al. Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers. Int J Radiat Oncol Biol Phys \u00a02000;48:1591\u20137.","DOI":"10.1016\/S0360-3016(00)00809-9"},{"key":"2024050213310410700_R38","doi-asserted-by":"crossref","unstructured":"Shirato H, Shimizu S, Kunieda T, Kitamura K, van Herk M, Kagei K, et al. Physical aspects of a real-time tumor-tracking system for gated radiotherapy. Int J Radiat Oncol Biol Phys \u00a02000;48:1187\u201395.","DOI":"10.1016\/S0360-3016(00)00748-3"},{"key":"2024050213310410700_R39","doi-asserted-by":"crossref","unstructured":"Hugo GD, Agazaryan N, Solberg TD. An evaluation of gating window size, delivery method, and composite field dosimetry of respiratory-gated IMRT. Med Phys \u00a02002;29:2517\u201325.","DOI":"10.1118\/1.1514578"},{"key":"2024050213310410700_R40","doi-asserted-by":"crossref","unstructured":"Kubo HD, Wang L. Introduction of audio gating to further reduce organ motion in breathing synchronized radiotherapy. Med Phys \u00a02002;29:345\u201350.","DOI":"10.1118\/1.1448826"},{"key":"2024050213310410700_R41","doi-asserted-by":"crossref","unstructured":"Vedam SS, Keall PJ, Kini VR, Mohan R. Determining parameters for respiration-gated radiotherapy. Med Phys \u00a02001;28:2139\u201346.","DOI":"10.1118\/1.1406524"},{"key":"2024050213310410700_R42","doi-asserted-by":"crossref","unstructured":"Kini VR, Vedam SS, Keall PJ, Patil S, Chen C, Mohan R. Patient training in respiratory-gated radiotherapy. Med Dosim \u00a02003;28:7\u201311.","DOI":"10.1016\/S0958-3947(02)00136-X"},{"key":"2024050213310410700_R43","doi-asserted-by":"crossref","unstructured":"Ramsey CR, Scaperoth D, Arwood D, Oliver AL. Clinical efficacy of respiratory gated conformal radiation therapy. Med Dosim \u00a01999;24:115\u20139.","DOI":"10.1016\/S0958-3947(99)00006-0"},{"key":"2024050213310410700_R44","doi-asserted-by":"crossref","unstructured":"Jaffray DA, Siewerdsen JH, Wong JW, Martinez AA. Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys \u00a02002;53:1337\u201349.","DOI":"10.1016\/S0360-3016(02)02884-5"},{"key":"2024050213310410700_R45","doi-asserted-by":"crossref","unstructured":"Morr J, DiPetrillo T, Tsai JS, Engler M, Wazer DE. Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys \u00a02002;53:1124\u20139.","DOI":"10.1016\/S0360-3016(02)02820-1"},{"key":"2024050213310410700_R46","doi-asserted-by":"crossref","unstructured":"Lattanzi J, McNeeley S, Donnelly S, Palacio E, Hanlon A, Schultheiss TE, et al. Ultrasound-based stereotactic guidance in prostate cancer-quantification of organ motion and set-up errors in external beam radiation therapy. Comput Aided Surg \u00a02000;5:289\u201395.","DOI":"10.1002\/1097-0150(2000)5:4<289::AID-IGS7>3.0.CO;2-D"},{"key":"2024050213310410700_R47","doi-asserted-by":"crossref","unstructured":"Logue JP, Sharrock CL, Cowan RA, Read G, Marrs J, Mott D. Clinical variability of target volume description in conformal radiotherapy planning. Int J Radiat Oncol Biol Phys \u00a01998;41:929\u201331.","DOI":"10.1016\/S0360-3016(98)00148-5"},{"key":"2024050213310410700_R48","doi-asserted-by":"crossref","unstructured":"Seddon B, Bidmead M, Wilson J, Khoo V, Dearnaley D. Target volume definition in conformal radiotherapy for prostate cancer: quality assurance in the MRC RT-01 trial. Radiother Oncol \u00a02000;56:73\u201383.","DOI":"10.1016\/S0167-8140(00)00191-2"},{"key":"2024050213310410700_R49","doi-asserted-by":"crossref","unstructured":"Weiss E, Hess CF. The impact of gross tumor volume (GTV) and clinical target volume (CTV) definition on the total accuracy in radiotherapy theoretical aspects and practical experiences. Strahlenther Onkol \u00a02003;179:21\u201330.","DOI":"10.1007\/s00066-003-0976-5"},{"key":"2024050213310410700_R50","doi-asserted-by":"crossref","unstructured":"Williams PC. IMRT: delivery techniques and quality assurance. Br J Radiol \u00a02003;76:766\u201376.","DOI":"10.1259\/bjr\/12907222"},{"key":"2024050213310410700_R51","doi-asserted-by":"crossref","unstructured":"Chui CS, Spirou S, LoSasso T. Testing of dynamic multileaf collimation. Med Phys \u00a01996;23:635\u201341.","DOI":"10.1118\/1.597699"},{"key":"2024050213310410700_R52","doi-asserted-by":"crossref","unstructured":"Low DA, Harms WB, Mutic S, Purdy JA. A technique for the quantitative evaluation of dose distributions. Med Phys \u00a01998;25:656\u201361.","DOI":"10.1118\/1.598248"},{"key":"2024050213310410700_R53","doi-asserted-by":"crossref","unstructured":"Leal A, Sanchez-Doblado F, Arrans R, Rosello J, Pavon EC, Lagares JI. Routine IMRT verification by means of an automated Monte Carlo simulation system. Int J Radiat Oncol Biol Phys \u00a02003;56:58\u201368.","DOI":"10.1016\/S0360-3016(03)00067-1"},{"key":"2024050213310410700_R54","doi-asserted-by":"crossref","unstructured":"Fielding AL, Evans PM, Clark CH. The use of electronic portal imaging to verify patient position during intensity-modulated radiotherapy delivered by the dynamic MLC technique. Int J Radiat Oncol Biol Phys \u00a02002;54:1225\u201334.","DOI":"10.1016\/S0360-3016(02)03749-5"},{"key":"2024050213310410700_R55","unstructured":"Miles EA, Clark CH, Guerro Urbano MT, Dearnaley DP, Nutting CM. How routine can IMRT become in daily clinical practice? Clin Oncol \u00a02003;15,S30:40."}],"container-title":["The British Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/76\/912\/850\/57384546\/bjr_19737738.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/76\/912\/850\/57384546\/bjr_19737738.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,2]],"date-time":"2024-05-02T13:34:07Z","timestamp":1714656847000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjr\/article\/76\/912\/850\/7470642"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,12,1]]},"references-count":55,"journal-issue":{"issue":"912","published-online":{"date-parts":[[2014,1,28]]},"published-print":{"date-parts":[[2003,12,1]]}},"URL":"https:\/\/doi.org\/10.1259\/bjr\/19737738","relation":{},"ISSN":["0007-1285","1748-880X"],"issn-type":[{"value":"0007-1285","type":"print"},{"value":"1748-880X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2003,12,1]]},"published":{"date-parts":[[2003,12,1]]}}}