{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T13:14:42Z","timestamp":1760015682249,"version":"3.41.2"},"reference-count":28,"publisher":"Oxford University Press (OUP)","issue":"1100","license":[{"start":{"date-parts":[[2019,5,24]],"date-time":"2019-05-24T00:00:00Z","timestamp":1558656000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,8,1]]},"abstract":"<jats:sec>\n                  <jats:title>Objectives:<\/jats:title>\n                  <jats:p>To evaluate the added value of spectral results derived from Spectral Detector CT (SDCT) to the characterization of renal cystic lesions (RCL).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods:<\/jats:title>\n                  <jats:p>This retrospective study was approved by the local Institutional review board. 70 consecutive patients who underwent abdominopelvic SDCT and had at least one RCL were included. 84 RCL were categorized as simple, complex or neoplastic based on attenuation values on single-phase post-contrast images. Attenuation values were measured in each lesion on standard conventional CT images (stCI) and virtual monoenergetic images of 40keV and 100keV. A spectral curve slope was calculated and intra lesional iodine concentration (IC) was measured using iodine-density maps. Reference standard was established using histopathologic correlation, prior and follow-up imaging. Analysis of variance (ANOVA) was used to compare between the groups.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results:<\/jats:title>\n                  <jats:p>Mean attenuation values for benign simple and complex RCL differed significantly (42 \u00b1 16 vs 8 \u00b1 3 HU; p &amp;lt; 0.001). IC was almost identical in benign simple and complex RCL (0.23 \u00b1 0.04 mg ml\u22121 \u00a0vs 0.24 \u00b1 0.04 mg ml\u22121), while IC in neoplastic RCL was significantly higher (2.10 \u00b1 0.08 mg ml\u22121 ; p &amp;lt; 0.001). The mean spectral curve slope did not differ significantly between simple and complex RCL (0.30 \u00b1 0.03 vs 0.33 \u00b1 0.05) but was significantly higher in neoplastic RCL (2.60 \u00b1 0.10; p &amp;lt; 0.001).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions:<\/jats:title>\n                  <jats:p>Spectral results of SDCT are highly promising in distinguishing benign complex RCL from enhancing neoplastic RCL based on single-phase post-contrast imaging only.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Advances in knowledge:<\/jats:title>\n                  <jats:p>SDCT can assist in differentiating between benign complex and neoplastic renal cystic lesions.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1259\/bjr.20180915","type":"journal-article","created":{"date-parts":[[2019,5,24]],"date-time":"2019-05-24T12:47:23Z","timestamp":1558702043000},"source":"Crossref","is-referenced-by-count":12,"title":["Renal cystic lesions characterization using spectral detector CT (SDCT): Added value of spectral results"],"prefix":"10.1093","volume":"92","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4293-3226","authenticated-orcid":false,"given":"Rivka","family":"Kessner","sequence":"first","affiliation":[{"name":"Department of Radiology, University Hospitals Cleveland Medical Center and Case Western Reserve University , Cleveland , Ohio, USA"},{"name":"Department of Diagnostic Imaging, Sackler Faculty of Medicine, Tel Aviv University , Tel Aviv , Israel"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nils","family":"Gro\u00dfe Hokamp","sequence":"additional","affiliation":[{"name":"Department of Radiology, University Hospitals Cleveland Medical Center and Case Western Reserve University , Cleveland , Ohio, USA"},{"name":"University Hospital Cologne, Institute for Diagnostic and Interventional Radiology , Cologne , Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Les","family":"Ciancibello","sequence":"additional","affiliation":[{"name":"Department of Radiology, University Hospitals Cleveland Medical Center and Case Western Reserve University , Cleveland , Ohio, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nikhil","family":"Ramaiya","sequence":"additional","affiliation":[{"name":"Department of Radiology, University Hospitals Cleveland Medical Center and Case Western Reserve University , Cleveland , Ohio, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karin A.","family":"Herrmann","sequence":"additional","affiliation":[{"name":"Department of Radiology, University Hospitals Cleveland Medical Center and Case Western Reserve University , Cleveland , Ohio, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2019,5,24]]},"reference":[{"key":"2024050214451266800_b1","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/j.jacr.2014.12.012","article-title":"ACR appropriateness criteria indeterminate renal mass","volume":"12","author":"Heilbrun","year":"2015","journal-title":"J Am Coll Radiol"},{"key":"2024050214451266800_b2","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1148\/radiol.11111595","article-title":"The Bosniak renal cyst classification: 25 years later","volume":"262","author":"Bosniak","year":"2012","journal-title":"Radiology"},{"key":"2024050214451266800_b3","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1148\/rg.351130016","article-title":"CT and MR imaging for evaluation of cystic renal lesions and diseases","volume":"35","author":"Wood","year":"2015","journal-title":"Radiographics"},{"key":"2024050214451266800_b4","doi-asserted-by":"crossref","first-page":"139","DOI":"10.2214\/AJR.10.5920","article-title":"Incidental finding of renal masses at unenhanced CT: prevalence and analysis of features for guiding management","volume":"197","author":"O'Connor","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"2024050214451266800_b5","doi-asserted-by":"crossref","first-page":"W640","DOI":"10.2214\/AJR.14.14094","article-title":"Dual-energy MDCT for imaging the renal mass","volume":"204","author":"Mileto","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"2024050214451266800_b6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/RLI.0b013e3181e33189","article-title":"Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant","volume":"45","author":"Graser","year":"2010","journal-title":"Invest Radiol"},{"key":"2024050214451266800_b7","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.2214\/AJR.16.17742","article-title":"Update of dual-energy CT applications in the genitourinary tract","volume":"208","author":"Kaza","year":"2017","journal-title":"AJR Am J Roentgenol"},{"key":"2024050214451266800_b8","doi-asserted-by":"crossref","first-page":"20160632","DOI":"10.1259\/bjr.20160632","article-title":"Preliminary study on the differentiation between parapelvic cyst and hydronephrosis with non-calculous using only pre-contrast dual-energy spectral CT scans","volume":"90","author":"Han","year":"2017","journal-title":"Br J Radiol"},{"key":"2024050214451266800_b9","doi-asserted-by":"crossref","first-page":"20180215","DOI":"10.1259\/bjr.20180215","article-title":"Low contrast material dose coronary computed tomographic angiography using a dual-layer spectral detector system in patients at risk for contrast-induced nephropathy","volume":"92","author":"Oda","year":"2019","journal-title":"Br J Radiol"},{"key":"2024050214451266800_b10","doi-asserted-by":"crossref","first-page":"20170290","DOI":"10.1259\/bjr.20170290","article-title":"Quantifying potential reduction in contrast dose with monoenergetic images synthesized from dual-layer detector spectral CT","volume":"90","author":"Tsang","year":"2017","journal-title":"Br J Radiol"},{"key":"2024050214451266800_b11","doi-asserted-by":"crossref","first-page":"2098","DOI":"10.1007\/s00330-018-5744-0","article-title":"Precision and reliability of liver iodine quantification from spectral detector CT: evidence from phantom and patient data","volume":"29","author":"Gro\u00dfe Hokamp","year":"2019","journal-title":"Eur Radiol"},{"key":"2024050214451266800_b12","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/radiol.2015142631","article-title":"Dual- and Multi-Energy CT: principles, technical approaches, and clinical applications","volume":"276","author":"McCollough","year":"2015","journal-title":"Radiology"},{"key":"2024050214451266800_b13","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1007\/s00261-016-0967-5","article-title":"Quantitative iodine content threshold for discrimination of renal cell carcinomas using rapid kV-switching dual-energy CT","volume":"42","author":"Zarzour","year":"2017","journal-title":"Abdom Radiol"},{"key":"2024050214451266800_b14","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1148\/radiol.2522080557","article-title":"Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images?","volume":"252","author":"Graser","year":"2009","journal-title":"Radiology"},{"key":"2024050214451266800_b15","doi-asserted-by":"crossref","first-page":"W693","DOI":"10.2214\/AJR.10.5541","article-title":"Iodine quantification with dual-energy CT: phantom study and preliminary experience with renal masses","volume":"196","author":"Chandarana","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"2024050214451266800_b16","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1148\/radiol.14132856","article-title":"Impact of dual-energy multi-detector row CT with virtual monochromatic imaging on renal cyst pseudoenhancement: in vitro and in vivo study","volume":"272","author":"Mileto","year":"2014","journal-title":"Radiology"},{"key":"2024050214451266800_b17","doi-asserted-by":"crossref","first-page":"W100","DOI":"10.2214\/AJR.18.20527","article-title":"Diagnostic accuracy of dual-energy CT for evaluation of renal masses: systematic review and meta-analysis","volume":"212","author":"Salameh","year":"2019","journal-title":"AJR Am J Roentgenol"},{"key":"2024050214451266800_b18","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1097\/RLI.0b013e318229fef3","article-title":"Dual-energy computed tomography imaging of thyroid nodule specimens: comparison with pathologic findings","volume":"47","author":"Li","year":"2012","journal-title":"Invest Radiol"},{"key":"2024050214451266800_b19","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1148\/radiol.2018180544","article-title":"Axillary sentinel lymph nodes in breast cancer: quantitative evaluation at dual-energy CT","volume":"289","author":"Zhang","year":"2018","journal-title":"Radiology"},{"key":"2024050214451266800_b20","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1007\/s00330-008-1273-6","article-title":"Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study","volume":"19","author":"Brown","year":"2009","journal-title":"Eur Radiol"},{"key":"2024050214451266800_b21","doi-asserted-by":"crossref","first-page":"1026","DOI":"10.2214\/AJR.11.7711","article-title":"Dual-source dual-energy CT evaluation of complex cystic renal masses","volume":"199","author":"Ascenti","year":"2012","journal-title":"AJR Am J Roentgenol"},{"key":"2024050214451266800_b22","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1148\/radiol.10101170","article-title":"Detection of renal lesion enhancement with dual-energy multidetector CT","volume":"259","author":"Neville","year":"2011","journal-title":"Radiology"},{"key":"2024050214451266800_b23","doi-asserted-by":"crossref","first-page":"20150860","DOI":"10.1259\/bjr.20150860","article-title":"Evaluation of hyperdense renal lesions incidentally detected on single-phase post-contrast CT using dual-energy CT","volume":"89","author":"Cha","year":"2016","journal-title":"Br J Radiol"},{"key":"2024050214451266800_b24","doi-asserted-by":"crossref","first-page":"e198","DOI":"10.1016\/j.crad.2012.11.008","article-title":"Homogeneous high attenuation renal cysts and solid masses--differentiation with single phase dual energy computed tomography","volume":"68","author":"Liu","year":"2013","journal-title":"Clin Radiol"},{"key":"2024050214451266800_b25","doi-asserted-by":"crossref","first-page":"W1076","DOI":"10.2214\/AJR.11.6922","article-title":"Utility of iodine overlay technique and virtual unenhanced images for the characterization of renal masses by dual-energy CT","volume":"197","author":"Song","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"2024050214451266800_b26","doi-asserted-by":"crossref","first-page":"2288","DOI":"10.1007\/s00330-013-2811-4","article-title":"Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements","volume":"23","author":"Ascenti","year":"2013","journal-title":"Eur Radiol"},{"key":"2024050214451266800_b27","doi-asserted-by":"crossref","first-page":"366","DOI":"10.2214\/AJR.18.20115","article-title":"Dual-energy CT material density iodine quantification for distinguishing vascular from nonvascular renal lesions: normalization reduces Intermanufacturer threshold variability","volume":"212","author":"Patel","year":"2019","journal-title":"AJR Am J Roentgenol"},{"key":"2024050214451266800_b28","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.1016\/j.ejrad.2014.07.009","article-title":"Quantitative analysis of the dual-energy CT virtual spectral curve for focal liver lesions characterization","volume":"83","author":"Wang","year":"2014","journal-title":"Eur J Radiol"}],"container-title":["The British Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/92\/1100\/20180915\/57378582\/bjr.20180915.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/92\/1100\/20180915\/57378582\/bjr.20180915.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,2]],"date-time":"2024-05-02T15:00:43Z","timestamp":1714662043000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjr\/article\/doi\/10.1259\/bjr.20180915\/7448982"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,24]]},"references-count":28,"journal-issue":{"issue":"1100","published-online":{"date-parts":[[2019,5,24]]},"published-print":{"date-parts":[[2019,8,1]]}},"URL":"https:\/\/doi.org\/10.1259\/bjr.20180915","relation":{},"ISSN":["0007-1285","1748-880X"],"issn-type":[{"type":"print","value":"0007-1285"},{"type":"electronic","value":"1748-880X"}],"subject":[],"published-other":{"date-parts":[[2019,8,1]]},"published":{"date-parts":[[2019,5,24]]},"article-number":"20180915"}}