{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T11:35:46Z","timestamp":1761824146322,"version":"3.41.2"},"reference-count":22,"publisher":"Oxford University Press (OUP)","issue":"1105","license":[{"start":{"date-parts":[[2019,11,12]],"date-time":"2019-11-12T00:00:00Z","timestamp":1573516800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,1,1]]},"abstract":"<jats:sec>\n                  <jats:title>Objective:<\/jats:title>\n                  <jats:p>MRI provides clear visualization of spinal cord, tumor, and bone for patient positioning and verification during MRI-guided radiotherapy (MRI-RT). Therefore, we wished to evaluate spine stereotactic ablative radiotherapy (SABR) feasibility with MRI-RT. Given dosimetric limitations of first generation Co-60 MRI-RT, we then evaluated improvements by newer linear accelerator (linac) MRI-RT.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods:<\/jats:title>\n                  <jats:p>Nine spinal metastases were treated with Co-60 MRI-RT. Seven received a single 16 Gy fraction, and two received three fractions totaling 24 or 30 Gy. After replanning with linac MRI-RT software, comparisons of organ at risk and dose spillage objectives between Co-60 and linac plans were performed.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results:<\/jats:title>\n                  <jats:p>Spinal cord and cauda equina dose constraints were met in all Co-60 cases. Treatments were delivered successfully with real-time imaging during treatment and no treatment-related toxicities. While limits for dose spillage into surrounding soft tissues were not achieved due to the limitations of the Co-60 system, this could be corrected with linac MRI-RT delivery.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions:<\/jats:title>\n                  <jats:p>MRI-RT SABR of spinal metastases is feasible with Co-60 MRI-RT. Dose delivery is improved by linac MRI-RT.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Advances in knowledge:<\/jats:title>\n                  <jats:p>This is the first report of MRI-RT for SABR of spinal metastases. The enhanced visualization of anatomy by MRI may facilitate RT dose escalation for spine SABR.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1259\/bjr.20190655","type":"journal-article","created":{"date-parts":[[2019,10,31]],"date-time":"2019-10-31T12:55:35Z","timestamp":1572526535000},"source":"Crossref","is-referenced-by-count":9,"title":["MRI-guided stereotactic ablative radiation therapy of spinal bone metastases: a preliminary experience"],"prefix":"10.1093","volume":"93","author":[{"given":"Ricardo","family":"Llorente","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, Miller School of Medicine, University of Miami , Miami , United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benjamin O","family":"Spieler","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, Miller School of Medicine, University of Miami , Miami , United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James","family":"Victoria","sequence":"additional","affiliation":[{"name":"ViewRay, Inc , Oakwood Village, OH , United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristiane","family":"Takita","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, Miller School of Medicine, University of Miami , Miami , United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raphael","family":"Yechieli","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, Miller School of Medicine, University of Miami , Miami , United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John C","family":"Ford","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, Miller School of Medicine, University of Miami , Miami , United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karen","family":"Brown","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, Miller School of Medicine, University of Miami , Miami , United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael A","family":"Samuels","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, Miller School of Medicine, University of Miami , Miami , United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric A","family":"Mellon","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, Miller School of Medicine, University of Miami , Miami , United States"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2019,11,12]]},"reference":[{"key":"2024050215104741000_b1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/00007632-199001000-00001","article-title":"Spinal metastases: the obvious, the occult, and the impostors","volume":"15","author":"Wong","year":"1990","journal-title":"Spine"},{"key":"2024050215104741000_b2","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/j.jpainsymman.2007.04.020","article-title":"Pain control by image-guided radiosurgery for solitary spinal metastasis","volume":"35","author":"Ryu","year":"2008","journal-title":"J Pain Symptom Manage"},{"key":"2024050215104741000_b3","first-page":"288","article-title":"Stereotactic radiosurgery for spinal metastases from renal cell carcinoma","volume":"3","author":"Gerszten","year":"2005","journal-title":"J Neurosurg"},{"issue":"5-6","key":"2024050215104741000_b4","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1159\/000091952","article-title":"Radiosurgery for the treatment of spinal melanoma metastases","volume":"83","author":"Gerszten","year":"2005","journal-title":"Stereotact Funct Neurosurg"},{"key":"2024050215104741000_b5","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1016\/j.ijrobp.2008.02.074","article-title":"Dosimetric effect of translational and rotational errors for patients undergoing image-guided stereotactic body radiotherapy for spinal metastases","volume":"71","author":"Wang","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2024050215104741000_b6","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.semradonc.2014.02.008","article-title":"The ViewRay system: magnetic Resonance\u2013Guided and controlled radiotherapy","volume":"24","author":"Mutic","year":"2014","journal-title":"Semin Radiat Oncol"},{"key":"2024050215104741000_b7","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1148\/rg.284075031","article-title":"Steady-State MR imaging sequences: physics, classification, and clinical applications","volume":"28","author":"Chavhan","year":"2008","journal-title":"Radiographics"},{"key":"2024050215104741000_b8","doi-asserted-by":"crossref","first-page":"1474","DOI":"10.3109\/0284186X.2015.1062541","article-title":"Comparison of onboard low-field magnetic resonance imaging versus onboard computed tomography for anatomy visualization in radiotherapy","volume":"54","author":"Noel","year":"2015","journal-title":"Acta Oncol"},{"key":"2024050215104741000_b9","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/j.radonc.2016.06.013","article-title":"A comparative planning study for lung SABR between tri-Co-60 magnetic resonance image guided radiation therapy system and volumetric modulated Arc therapy","volume":"120","author":"Park","year":"2016","journal-title":"Radiother Oncol"},{"key":"2024050215104741000_b10","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20160652","article-title":"Quality of tri-Co-60 MR-IGRT treatment plans in comparison with VMAT treatment plans for spine SABR","volume":"90","author":"Choi","year":"2017","journal-title":"Br J Radiol"},{"key":"2024050215104741000_b11","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.prro.2013.05.001","article-title":"RTOG 0631 phase 2\/3 study of image guided stereotactic radiosurgery for localized (1-3) spine metastases: phase 2 results","volume":"4","author":"Ryu","year":"2014","journal-title":"Pract Radiat Oncol"},{"key":"2024050215104741000_b12","doi-asserted-by":"crossref","first-page":"e597","DOI":"10.1016\/j.ijrobp.2012.03.009","article-title":"International spine radiosurgery Consortium consensus guidelines for target volume definition in spinal stereotactic radiosurgery","volume":"83","author":"Cox","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2024050215104741000_b13","doi-asserted-by":"crossref","first-page":"e291","DOI":"10.1016\/j.prro.2016.05.004","article-title":"Rationale of technical requirements for NRG-BR001: the first NCI-sponsored trial of SBRT for the treatment of multiple metastases","volume":"6","author":"Al-Hallaq","year":"2016","journal-title":"Pract Radiat Oncol"},{"key":"2024050215104741000_b14","doi-asserted-by":"crossref","first-page":"4525","DOI":"10.1088\/1361-6560\/aa6e1a","article-title":"Characterization of spatial distortion in a 0.35 T MRI-guided radiotherapy system","volume":"62","author":"Ginn","year":"2017","journal-title":"Phys Med Biol"},{"issue":"1 Suppl","key":"2024050215104741000_b15","doi-asserted-by":"crossref","first-page":"S57","DOI":"10.1016\/j.ijrobp.2007.06.086","article-title":"Quality assurance for the geometric accuracy of cone-beam CT guidance in radiation therapy","volume":"71","author":"Bissonnette","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2024050215104741000_b16","doi-asserted-by":"crossref","DOI":"10.1002\/mp.13002","article-title":"First clinical implementation of real-time, real anatomy tracking and radiation beam control","author":"Green","year":"2018","journal-title":"Med Phys"},{"key":"2024050215104741000_b17","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1118\/1.2839097","article-title":"Evaluation of residual patient position variation for spinal radiosurgery using the novalis image guided system","volume":"35","author":"Jin","year":"2008","journal-title":"Med Phys"},{"key":"2024050215104741000_b18","doi-asserted-by":"crossref","first-page":"L41","DOI":"10.1088\/1361-6560\/aa9517","article-title":"First patients treated with a 1.5 T MRI-Linac: clinical proof of concept of a high-precision, high-field MRI guided radiotherapy treatment","volume":"62","author":"Raaymakers","year":"2017","journal-title":"Phys Med Biol"},{"key":"2024050215104741000_b19","doi-asserted-by":"crossref","first-page":"4943","DOI":"10.1088\/0031-9155\/58\/14\/4943","article-title":"Three-Dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes","volume":"58","author":"Bjerre","year":"2013","journal-title":"Phys Med Biol"},{"key":"2024050215104741000_b20","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1016\/j.ijrobp.2015.03.037","article-title":"Outcomes for spine stereotactic body radiation therapy and an analysis of predictors of local recurrence","volume":"92","author":"Bishop","year":"2015","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2024050215104741000_b21","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1016\/j.ijrobp.2009.10.003","article-title":"Correlation of local failure with measures of dose insufficiency in the high-dose single-fraction treatment of bony metastases","volume":"77","author":"Lovelock","year":"2010","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2024050215104741000_b22","doi-asserted-by":"crossref","first-page":"1481","DOI":"10.1016\/j.ijrobp.2018.07.2023","article-title":"Phase 1 study of spinal cord constraint relaxation with single session spine stereotactic radiosurgery in the primary management of patients with inoperable, previously unirradiated metastatic epidural spinal cord compression","volume":"102","author":"Ghia","year":"2018","journal-title":"Int J Radiat Oncol Biol Phys"}],"container-title":["The British Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/93\/1105\/20190655\/54756918\/bjr.20190655.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/93\/1105\/20190655\/54756918\/bjr.20190655.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,2]],"date-time":"2024-05-02T16:02:38Z","timestamp":1714665758000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjr\/article\/doi\/10.1259\/bjr.20190655\/7478598"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,12]]},"references-count":22,"journal-issue":{"issue":"1105","published-online":{"date-parts":[[2019,11,12]]},"published-print":{"date-parts":[[2020,1,1]]}},"URL":"https:\/\/doi.org\/10.1259\/bjr.20190655","relation":{},"ISSN":["0007-1285","1748-880X"],"issn-type":[{"type":"print","value":"0007-1285"},{"type":"electronic","value":"1748-880X"}],"subject":[],"published-other":{"date-parts":[[2020,1,1]]},"published":{"date-parts":[[2019,11,12]]},"article-number":"20190655"}}