{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T12:06:05Z","timestamp":1787313965167,"version":"build-2736575974"},"reference-count":10,"publisher":"Oxford University Press (OUP)","issue":"1111","license":[{"start":{"date-parts":[[2020,4,24]],"date-time":"2020-04-24T00:00:00Z","timestamp":1587686400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,7,1]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>The objective of this work was to undertake a non-judgemental study of prostate planning practice across the UK by inviting all departments to undertake the same case.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>An invitation to take part in the study was sent to the Heads of all UK radiotherapy departments and posted on the UK Medical Physics mailbase. Individuals interested in participating were able to access a single anonymised CT dataset for download with the prostate gland, seminal vesicles, bladder, rectum, bowel, femoral heads, and penile bulb outlined. A brief patient history was also supplied. Participants were asked to create planning target volumes (PTVs) according to their local clinical protocol and plan to give 60\u2009Gy in 20 fractions to the PTV receiving the highest dose. No guidance was given for acceptable organ at risk doses. Dicom plan and dose information was loaded back into ProKnow for analysis by contributors.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>There were 102 plan submissions made to the study representing 48 different UK radiotherapy departments. Seventeen distinct methodologies for creating the prescription PTV from the prostate and seminal vesicles were identified with the ethos of the CHHIP trial protocol for margin growing followed in nearly two-thirds of cases. Positive correlations were found when assessing the doses received by the bladder and rectum against the volume of the PTV to which 60\u2009Gy was prescribed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>A national planning study whereby staff from a multitude of radiotherapy departments create plans based solely on a single dataset is feasible. The cohort of data was made available to all participants following the study to enable self-assessment and benchmarking against that of their peers.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Advances in knowledge:<\/jats:title>\n                    <jats:p>This is the first UK wide treatment planning study to investigate local clinical prostate planning practice. This has given UK departments the opportunity to evaluate their planning practices against those of their peers.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1259\/bjr.20200142","type":"journal-article","created":{"date-parts":[[2020,4,8]],"date-time":"2020-04-08T13:47:17Z","timestamp":1586353637000},"source":"Crossref","is-referenced-by-count":7,"title":["A UK wide study of current prostate planning practice"],"prefix":"10.1093","volume":"93","author":[{"given":"Timothy","family":"Taylor","sequence":"first","affiliation":[{"name":"Department of Medical Physics & Bioengineering, Royal United Hospitals Bath NHS Foundation Trust, Combe Park , Bath , BA1 3NG"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neil","family":"Richmond","sequence":"additional","affiliation":[{"name":"Northern Centre for Cancer Care, Freeman Hospital, Freeman Road , Newcastle upon Tyne , NE7 7DN"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2020,4,24]]},"reference":[{"key":"2024050215281352900_b1","unstructured":"Cancer Research UK\n.. Available from:\nhttps:\/\/www.cancerresearchuk.org\/health-professional\/cancer-statistics\/statistics-by-cancer-type\/prostate-cancer\n[\nAccessed October 2019\n]."},{"key":"2024050215281352900_b2","unstructured":"National Cancer Registration & Analysis Service and Cancer Research UK: \"Chemotherapy, Radiotherapy and Tumour Resections in England: 2013-2014\" workbook\n.\nLondon\n:\nNCRAS\n;.\n2017\n."},{"key":"2024050215281352900_b3","unstructured":"CHHIP - Conventional or Hypofractionated High Dose Intensity Modulated Radiotherapy for Prostate Cancer Protocol Version 8.0, November\n\u00a0Report No.: .: ISRCTN No.: ISRCTN97182923\n..\n2009\n."},{"key":"2024050215281352900_b4","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.ejmp.2019.05.003","article-title":"Plan quality improvement by DVH sharing and planner's experience: results of a SBRT multicentric planning study on prostate","volume":"62","author":"Villaggi","year":"2019","journal-title":"Phys Med"},{"key":"2024050215281352900_b5","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1016\/j.meddos.2017.07.001","article-title":"Improving plan quality for prostate volumetric-modulated Arc therapy","volume":"42","author":"Wright","year":"2017","journal-title":"Med Dosim"},{"key":"2024050215281352900_b6","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/j.prro.2016.04.005","article-title":"Interobserver variability in radiation therapy plan output: results of a single-institution study","volume":"6","author":"Berry","year":"2016","journal-title":"Pract Radiat Oncol"},{"key":"2024050215281352900_b7","unstructured":"ProKnow Systems [Internet]. Sanford, FL (US): ProKnow, LLC; c2018 [cited 2019 Jul 22]\n.. Available from:\nAvailable from: https:\/\/proknowsystems.com\/\n."},{"key":"2024050215281352900_b8","doi-asserted-by":"crossref","first-page":"4435","DOI":"10.1118\/1.4923175","article-title":"Methods, software and datasets to verify DVH calculations against analytical values: twenty years later","volume":"42","author":"Nelms","year":"2015","journal-title":"Med Phys"},{"key":"2024050215281352900_b9","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.radonc.2014.08.029","article-title":"Radiotherapy equipment and departments in the European countries: final results from the ESTRO-HERO survey","volume":"112","author":"Grau","year":"2014","journal-title":"Radiother Oncol"},{"key":"2024050215281352900_b10","unstructured":"NHS England Specialised Services Clinical Reference Group for Radiotherapy\n          \n.\nClinical Commissioning Policy: Hypofractionated external beam radiotherapy in the treatment of localised prostate cancer (adults). NHS England: 170021\/P. October 2017\n.\nVisited 28\/01\/2020.\n. Available from:\nhttps:\/\/www.england.nhs.uk\/publication\/clinical-commissioning-policy-hypofractionated-external-beam-radiotherapy-in-the-treatment-of-localised-prostate-cancer-adults\/\n."}],"container-title":["The British Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/93\/1111\/20200142\/57376761\/bjr.20200142.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/93\/1111\/20200142\/57376761\/bjr.20200142.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,2]],"date-time":"2024-05-02T12:10:14Z","timestamp":1714651814000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjr\/article\/doi\/10.1259\/bjr.20200142\/7452020"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,24]]},"references-count":10,"journal-issue":{"issue":"1111","published-online":{"date-parts":[[2020,4,24]]},"published-print":{"date-parts":[[2020,7,1]]}},"URL":"https:\/\/doi.org\/10.1259\/bjr.20200142","relation":{},"ISSN":["0007-1285","1748-880X"],"issn-type":[{"value":"0007-1285","type":"print"},{"value":"1748-880X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2020,7,1]]},"published":{"date-parts":[[2020,4,24]]},"article-number":"20200142"}}