{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T18:18:00Z","timestamp":1793038680415,"version":"4.5.0"},"reference-count":28,"publisher":"Oxford University Press (OUP)","issue":"1144","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BJR"],"published-print":{"date-parts":[[2023,3,1]]},"abstract":"<jats:sec><jats:title>Objectives:<\/jats:title><jats:p> Patients who need torsion measurement of the lower limb often have metal implants hindering e.g. MRI. A new ultra-low-dose (ULD-)CT protocol might be feasible for torsion measurement at cost of relatively low radiation exposure. <\/jats:p><\/jats:sec><jats:sec><jats:title>Methods:<\/jats:title><jats:p> We retrospectively included all patients with clinically indicated torsion measurement in the period July 2019 to June 2021 and metal implants in the scanning field. The ULD-CT protocol comprised automated tube current time product and automated tube voltage with reference settings of 100kV\/20mAs (hip), 80kV\/20mAs (knee) and 80kV\/10mAs (ankle). Femoral neck anteversion, tibial, intra-articular knee and overall leg torsion measurements were performed by two radiologists independently. Diagnostic confidence regarding the delineation of the relevant cortical bone was rated on a 5-point Likert scale (1 = non-diagnostic, 5 = excellent). <\/jats:p><\/jats:sec><jats:sec><jats:title>Results:<\/jats:title><jats:p> 102 consecutive patients could be included (BMI 27.38 \u00b1 5.85) with 154 metal implants. Median total dose length product of the ULD-CT-torsion measurement was 16.5mGycm [11-39]. Both readers showed high agreement with a maximum torsional difference of 4.1\u00b0. Diagnostic confidence was rated best (5\/5) in 92.2% (reader 1) and 93.1% (reader 2) with a worst rating of 3\/5. <\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion:<\/jats:title><jats:p> The new ULD-CT protocol is feasible for torsion measurement of the lower limb \u2013 even in patients with metal implants. <\/jats:p><\/jats:sec><jats:sec><jats:title>Advances in knowledge:<\/jats:title><jats:p> Metal implants are not an obstacle for ULD-CT torsion measurements of the lower limb. <\/jats:p><\/jats:sec>","DOI":"10.1259\/bjr.20220495","type":"journal-article","created":{"date-parts":[[2023,2,2]],"date-time":"2023-02-02T13:23:20Z","timestamp":1675344200000},"source":"Crossref","is-referenced-by-count":5,"title":["Ultra-low-dose CT is feasible for torsion measurement of the lower limb in patients with metal implants"],"prefix":"10.1093","volume":"96","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6340-8343","authenticated-orcid":false,"given":"Gabriel","family":"Keller","sequence":"first","affiliation":[{"name":"Department of Diagnostic and Interventional Radiology, University Hospital T\u00fcbingen, Eberhard Karls University T\u00fcbingen, Hoppe-Seyler-Str, T\u00fcbingen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonard","family":"Gr\u00fcnwald","sequence":"additional","affiliation":[{"name":"Department of Traumatology and Reconstructive Surgery, BG Trauma Center T\u00fcbingen, Eberhard Karls University of T\u00fcbingen, Schnarrenberg-Str, T\u00fcbingen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabian","family":"Springer","sequence":"additional","affiliation":[{"name":"Department of Diagnostic and Interventional Radiology, University Hospital T\u00fcbingen, Eberhard Karls University T\u00fcbingen, Hoppe-Seyler-Str, T\u00fcbingen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","reference":[{"key":"b1","volume-title":"S1-Guideline: Patella-Luxation","author":"Jagodzinski M","year":"2014"},{"key":"b2","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-013-1289-8"},{"key":"b3","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.19.00731"},{"key":"b4","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2013.09.010"},{"key":"b5","doi-asserted-by":"publisher","DOI":"10.21037\/atm.2019.08.49"},{"key":"b6","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2020192723"},{"key":"b7","doi-asserted-by":"publisher","DOI":"10.1001\/archinternmed.2009.440"},{"key":"b8","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.2235592100"},{"key":"b9","doi-asserted-by":"publisher","DOI":"10.4065\/mcp.2010.0260"},{"issue":"7","key":"b10","doi-asserted-by":"crossref","DOI":"10.3390\/diagnostics11071209","volume":"11","author":"Keller G","year":"2021","journal-title":"Diagnostics (Basel)"},{"key":"b11","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-020-07528-8"},{"issue":"3","key":"b12","first-page":"245","volume":"157","author":"Waidelich HA","year":"1992","journal-title":"The methods, normal values and radiation load]. Rofo"},{"key":"b13","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcm.2016.02.012"},{"key":"b14","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.bmb.a011611"},{"key":"b15","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(16)30054-X"},{"key":"b16","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2303021726"},{"key":"b17","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-016-1780-0"},{"key":"b18","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-016-4263-0"},{"key":"b19","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-017-5168-2"},{"key":"b20","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr.20160228"},{"key":"b21","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2018.01.014"},{"key":"b22","doi-asserted-by":"publisher","DOI":"10.3348\/kjr.2021.0140"},{"key":"b23","doi-asserted-by":"publisher","DOI":"10.3348\/kjr.2018.0715"},{"key":"b24","doi-asserted-by":"publisher","DOI":"10.3348\/kjr.2012.13.2.165"},{"key":"b25","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-021-07824-x"},{"key":"b26","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-021-03825-5"},{"key":"b27","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-020-07304-8"},{"key":"b28","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-019-03309-7"}],"container-title":["The British Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.birpublications.org\/doi\/pdf\/10.1259\/bjr.20220495","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,12]],"date-time":"2024-01-12T16:45:08Z","timestamp":1705077908000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjr\/article\/7471376"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,1]]},"references-count":28,"journal-issue":{"issue":"1144","published-print":{"date-parts":[[2023,3,1]]}},"alternative-id":["10.1259\/bjr.20220495"],"URL":"https:\/\/doi.org\/10.1259\/bjr.20220495","relation":{},"ISSN":["0007-1285","1748-880X"],"issn-type":[{"value":"0007-1285","type":"print"},{"value":"1748-880X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,1]]},"article-number":"20220495"}}