{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T17:16:50Z","timestamp":1788283010885,"version":"build-2803163510"},"reference-count":20,"publisher":"Oxford University Press (OUP)","issue":"1149","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,8,1]]},"abstract":"<jats:sec>\n                  <jats:title>Objectives:<\/jats:title>\n                  <jats:p>Aim of the study is to compare manual and semi-automatic measurements for aortic annulus assessment among different operators.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods:<\/jats:title>\n                  <jats:p>Eighty patients who underwent TAVI were retrospectively enrolled. The measurements manually performed by an experienced reader for aortic annulus (minimum and maximum diameters, perimeter, area), annulus-to-coronary ostia distance and time needed for the whole evaluation, were collected. The same operator (observer 1) and two less experienced readers (observer 2 and 3, with &amp;gt;5 years and 1\u2009year of experience, respectively) assessed the same measurements using a semi-automatic software. Differences between manual and semi-automatic measurements, reading time and suggested valves size derived by CT were compared.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results:<\/jats:title>\n                  <jats:p>Very good correlations were found between manual and software-aided measurements for aortic annulus area and perimeter in comparison with standard measurements for the three readers (ICC range 0.81\u20130.98). Good correlations were found for the distance with coronary ostia(0.75\u20130.79). The same area-derived prosthesis size for manual and semi-automatic measurements was selected in 96% of cases for observer 1; very good correlations were also found for observer 2 and 3 (ICC = 0.89\u2009and 0.88, respectively). Using semi-automatic measurements, the mean time needed for CT images was significantly lower for observers 1 and 2 (1.50 and 1.72versus\u20093.14\u2009min), respectively.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions:<\/jats:title>\n                  <jats:p>Pre-TAVI CT using semi-automatic software allows accurate and reproducible measurements, reducing reconstruction time up to 50% and is reliable even for operators with different experience.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Advances in knowledge:<\/jats:title>\n                  <jats:p>The use of semi-automatic dedicated software for CT in TAVI planning is reliable even for operators without long time experience and allows accurate and reproducible measurements improving pre-TAVI workflow.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1259\/bjr.20220733","type":"journal-article","created":{"date-parts":[[2023,7,14]],"date-time":"2023-07-14T11:22:47Z","timestamp":1689333767000},"source":"Crossref","is-referenced-by-count":5,"title":["Pre-TAVI aortic annulus sizing: comparison between manual and semi-automated new generation software measurements in operators with different experience"],"prefix":"10.1093","volume":"96","author":[{"given":"Andrea Daniele","family":"Annoni","sequence":"first","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Elisabetta","family":"Mancini","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eleonora","family":"Carlicchi","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS, University of Milan , Milan, Italy"},{"name":"ASST Grande Ospedale Metropolitano Niguarda , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marta","family":"Belmonte","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"},{"name":"Cardiovascular Center Aalst, OLV-Clinic , Aalst, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Formenti","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saima","family":"Mushtaq","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesca","family":"Marchetti","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Cilia","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Baggiano","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Fusini","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alice","family":"Bonomi","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Gennari","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piero","family":"Montorsi","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"},{"name":"Department of Clinical Sciences and Community Health, University of Milan , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mauro","family":"Pepi","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianluca","family":"Pontone","sequence":"additional","affiliation":[{"name":"Centro Cardiologico Monzino, IRCCS , Milan, Italy"},{"name":"Department of Clinical Sciences and Community Health, University of Milan , Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2023,7,25]]},"reference":[{"key":"2024050216080863000_b1","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","article-title":"Transcatheter versus surgical aortic-valve replacement in high-risk patients","volume":"364","author":"Smith","year":"2011","journal-title":"N Engl J Med"},{"key":"2024050216080863000_b2","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1056\/NEJMoa1514616","article-title":"Transcatheter or surgical aortic-valve replacement in intermediate-risk patients","volume":"374","author":"Leon","year":"2016","journal-title":"N Engl J Med"},{"key":"2024050216080863000_b3","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1016\/j.jacc.2013.05.015","article-title":"Aortic stenosis in the elderly: disease prevalence and number of candidates for Transcatheter aortic valve replacement: a meta-analysis and modeling study","volume":"62","author":"Osnabrugge","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"2024050216080863000_b4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jcct.2018.11.008","article-title":"Computed tomography imaging in the context of Transcatheter aortic valve implantation (TAVI) \/ Transcatheter aortic valve replacement (TAVR): an expert consensus document of the society of cardiovascular computed tomography","volume":"13","author":"Blanke","year":"2019","journal-title":"Journal of Cardiovascular Computed Tomography"},{"key":"2024050216080863000_b5","doi-asserted-by":"crossref","first-page":"4143","DOI":"10.1007\/s00330-020-06741-9","article-title":"Correction to: CT and MR imaging prior to Transcatheter aortic valve implantation: standardization of scanning protocols, measurements and reporting-a consensus document by the European society of cardiovascular Radiology (ESCR)","volume":"30","author":"Francone","year":"2020","journal-title":"Eur Radiol"},{"key":"2024050216080863000_b6","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20180196","article-title":"CT angiography prior to TAVI procedure using third-generation scanner with wide volume coverage: feasibility, renal safety and diagnostic accuracy for coronary tree","volume":"91","author":"Annoni","year":"2018","journal-title":"Br J Radiol"},{"key":"2024050216080863000_b7","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting Intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"},{"key":"2024050216080863000_b8","doi-asserted-by":"crossref","first-page":"94","DOI":"10.15420\/icr.2015.10.2.94","article-title":"Avoiding coronary occlusion and root rupture in TAVI - te role of pre-procedural imaging and Prosthesis selection","volume":"10","author":"Barbanti","year":"2015","journal-title":"Interv Cardiol"},{"key":"2024050216080863000_b9","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.jacc.2017.04.056","article-title":"Procedural experience for Transcatheter aortic valve replacement and relation to outcomes: the STS\/ACC TVT Registry","volume":"70","author":"Carroll","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"2024050216080863000_b10","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.jacc.2013.04.036","article-title":"The impact of integration of a Multidetector computed tomography Annulus area SIZING algorithm on outcomes of Transcatheter aortic valve replacement: a prospective, multicenter, controlled trial","volume":"62","author":"Binder","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"2024050216080863000_b11","first-page":"328","article-title":"Assessment of a novel software tool in the selection of aortic valve Prosthesis size for Transcatheter aortic valve replacement","volume":"26","author":"Vaitkus","year":"2014","journal-title":"J Invasive Cardiol"},{"key":"2024050216080863000_b12","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-020-67111-5","article-title":"Reliability and influence on decision making of fully-automated vs. semi-automated software packages for procedural planning in TAVI","volume":"10","author":"Meyer","year":"2020","journal-title":"Sci Rep"},{"key":"2024050216080863000_b13","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.jcct.2016.12.004","article-title":"Automatic 3d aortic Annulus SIZING by computed tomography in the planning of Transcatheter aortic valve implantation","volume":"11","author":"Queir\u00f3s","year":"2017","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2024050216080863000_b14","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1111\/echo.13483","article-title":"3d echocardiographic analysis of aortic Annulus for Transcatheter aortic valve replacement using novel aortic valve Quantification software: comparison with computed tomography","volume":"34","author":"Mediratta","year":"2017","journal-title":"Echocardiography"},{"key":"2024050216080863000_b15","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.echo.2018.01.007","article-title":"Validation of a novel software tool for automatic aortic Annular SIZING in three-dimensional Transesophageal echocardiographic images","volume":"31","author":"Queir\u00f3s","year":"2018","journal-title":"J Am Soc Echocardiogr"},{"key":"2024050216080863000_b16","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1093\/eurheartj\/ehm544","article-title":"Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a writing group deployed by the working group nuclear cardiology and cardiac CT of the European society of cardiology and the European Council of nuclear cardiology","volume":"29","author":"Schroeder","year":"2008","journal-title":"Eur Heart J"},{"key":"2024050216080863000_b17","first-page":"407","article-title":"ACCF\/SCCT\/ACR\/AHA\/ASE\/ASNC\/NASCI\/SCAI\/SCMR 2010 appropriate use criteria for cardiac computed tomography. A report of the American college of cardiology foundation appropriate use criteria task force, the society of cardiovascular computed tomography, the American college of Radiology, the American heart Association, the American society of echocardiography, the American society of nuclear cardiology, the North American society for cardiovascular imaging, the society for cardiovascular angiography and interventions, and the society for cardiovascular magnetic resonance","volume":"4","author":"Taylor","year":"2010","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2024050216080863000_b18","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/j.diii.2017.12.007","article-title":"Multidetector computed tomography SIZING of aortic Annulus prior to Transcatheter aortic valve replacement (TAVR): variability and impact of observer experience","volume":"99","author":"Le Couteulx","year":"2018","journal-title":"Diagn Interv Imaging"},{"key":"2024050216080863000_b19","doi-asserted-by":"crossref","first-page":"141","DOI":"10.11613\/BM.2015.015","article-title":"Understanding bland Altman analysis","volume":"25","author":"Giavarina","year":"2015","journal-title":"Biochem Med (Zagreb)"},{"key":"2024050216080863000_b20","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting Intraclass correlation coefficients for reliability research [published correction appears in J Chiropr MED","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"}],"container-title":["The British Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/96\/1149\/20220733\/57370703\/bjr.20220733.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/96\/1149\/20220733\/57370703\/bjr.20220733.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,2]],"date-time":"2024-05-02T18:31:04Z","timestamp":1714674664000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjr\/article\/doi\/10.1259\/bjr.20220733\/7469144"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,25]]},"references-count":20,"journal-issue":{"issue":"1149","published-online":{"date-parts":[[2023,7,25]]},"published-print":{"date-parts":[[2023,8,1]]}},"URL":"https:\/\/doi.org\/10.1259\/bjr.20220733","relation":{},"ISSN":["0007-1285","1748-880X"],"issn-type":[{"value":"0007-1285","type":"print"},{"value":"1748-880X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2023,8,1]]},"published":{"date-parts":[[2023,7,25]]},"article-number":"20220733"}}