{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,4]],"date-time":"2026-03-04T05:53:58Z","timestamp":1772603638788,"version":"3.50.1"},"reference-count":52,"publisher":"Oxford University Press (OUP)","issue":"873","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2000,9,1]]},"abstract":"<jats:p>New, complex radiotherapy delivery techniques require dosimeters that are able to measure complex three-dimensional dose distributions accurately and with good spatial resolution. Polymer gel is an emerging new dosimeter being applied to these challenges. The aim of this review is to present a practical overview of polymer gel dosimetry, including gel manufacture, imaging, calibration and application to radiotherapy verification. The dosimeters consist of a gel matrix within which is suspended a solution of acrylic molecules. These molecules polymerize upon exposure to radiation, with the degree of polymerization being proportional to absorbed dose. The polymer distribution can be measured in two or three dimensions using MRI or optical tomography and, after calibration, the images can be converted into radiation dose distributions. Manufacture of the gel is reported to be reproducible, and measured dose in the range 0-10 Gy is accurate to within 3-5%. In-plane image resolution of 1 mm x 1 mm, with image slice thicknesses of between 2-5 mm, is typically achievable using clinical 1.5 T MR scanners and standard T2 weighted imaging sequences. The gels have been used to verify a number of conventional and novel radiotherapy modalities, including brachytherapy, intensity modulated radiotherapy and stereotactic radiosurgery. All the studies have confirmed the value and versatility of the dosimetry technique.<\/jats:p>","DOI":"10.1259\/bjr.73.873.11064643","type":"journal-article","created":{"date-parts":[[2014,6,13]],"date-time":"2014-06-13T02:11:45Z","timestamp":1402625505000},"page":"919-929","source":"Crossref","is-referenced-by-count":109,"title":["Radiation dosimetry using polymer gels: methods and applications."],"prefix":"10.1093","volume":"73","author":[{"given":"M","family":"McJury","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M","family":"Oldham","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"V P","family":"Cosgrove","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P S","family":"Murphy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S","family":"Doran","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M O","family":"Leach","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S","family":"Webb","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2014,1,28]]},"reference":[{"key":"p_1","doi-asserted-by":"publisher","DOI":"10.1038\/166141a0"},{"key":"p_2","doi-asserted-by":"publisher","DOI":"10.1063\/1.1715877"},{"key":"p_3","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/35\/12\/001"},{"key":"p_4","doi-asserted-by":"publisher","DOI":"10.1016\/0020-708X(58)90053-X"},{"key":"p_5","volume-title":"Proc Soc Magn Reson Med 10th Annual Scienti\u00aec Meeting; 1991 August; San Francisco, CA. California: Society for Magnetic Resonance in Medicine: 705","author":"Audet C"},{"key":"p_6","doi-asserted-by":"publisher","DOI":"10.1016\/0730-725X(93)90030-H"},{"key":"p_7","volume-title":"Proceedings of the 1st International Workshop on Radiation Therapy Gel Dosimetry; 1999 July 21-23; Lexington KY. Edmonton, AB","author":"Schreiner JL"},{"key":"p_8","volume-title":"Laboratory techniques in biochemistry and molecular biology.","author":"Gordon AH.","year":"1973"},{"key":"p_9","doi-asserted-by":"publisher","DOI":"10.1039\/tf9676301699"},{"key":"p_10","doi-asserted-by":"publisher","DOI":"10.1098\/rspa.1954.0123"},{"key":"p_11","doi-asserted-by":"publisher","DOI":"10.1016\/0032-3861(84)90103-4"},{"key":"p_12","volume-title":"Radiation chemistry.","author":"Charlesby A.","year":"1987"},{"key":"p_13","volume-title":"Three dimensional detection, dosimetry and imaging of an energy \u00aeeld by formation of a polymer in a gel. US Patent #5 321 357","author":"Maryanski MJ","year":"1994"},{"key":"p_14","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/39\/9\/010"},{"key":"p_15","volume-title":"Proc Soc Magn Reson Med 6th Scienti\u00aec Meeting; 1998 April; Sydney, Australia. California, USA: Society for Magnetic Resonance in Medicine: 2167","author":"Schreiner LJ"},{"key":"p_16","doi-asserted-by":"publisher","DOI":"10.1118\/1.597717"},{"key":"p_17","unstructured":"Ba\u00c8ck SA\u00ca. Implementation of MRI gel dosimetry in radiation therapy. PhD thesis,Department of Radiation Physics, Malmo\u00c8 Lund University, Sweden, 1998."},{"key":"p_18","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/43\/5\/005"},{"key":"p_19","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/42\/2\/004"},{"key":"p_20","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/43\/10\/002"},{"key":"p_21","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/43\/3\/019"},{"key":"p_22","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-8140(98)00087-5"},{"key":"p_23","first-page":"550","author":"De Deene","year":"1998","journal-title":"Radiat Oncol"},{"key":"p_24","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/44\/8\/301"},{"key":"p_25","volume-title":"Bio-Rad Bulletin #1156","author":"Acrylamide","year":"1987"},{"key":"p_26","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/44\/8\/302"},{"key":"p_27","first-page":"951","volume":"22","author":"Maryanski MJ","year":"1995","journal-title":"Med Phys"},{"key":"p_28","first-page":"311","volume":"2","author":"Vachier MC","year":"1996","journal-title":"J Magn Reson Analysis"},{"key":"p_29","first-page":"950","volume":"22","author":"Maryanski MJ","year":"1995","journal-title":"Med Phys"},{"key":"p_30","first-page":"951","volume":"22","author":"Audet C","year":"1995","journal-title":"Med Phys"},{"key":"p_31","first-page":"1070","volume":"23","author":"Baldock C","year":"1996","journal-title":"Med Phys"},{"key":"p_32","first-page":"1012","volume":"35","author":"Farajollahi AR","year":"1997","journal-title":"J Int Fed Med Biol Eng"},{"key":"p_33","doi-asserted-by":"publisher","DOI":"10.1006\/jmrb.1996.0042"},{"key":"p_34","volume-title":"Proc Soc Magn Reson 3rd Scienti\u00aec Meeting; 1995 August; Nice, France. California, USA: Society for Magnetic Resonance in Medicine: 1102","author":"Zebrowska G"},{"key":"p_35","doi-asserted-by":"publisher","DOI":"10.1006\/jmre.1998.1371"},{"key":"p_36","volume-title":"Handbook of toxic and hazardous chemicals and carcinogens","author":"Sittig M.","year":"1985","edition":"2"},{"key":"p_37","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/45\/4\/303"},{"key":"p_38","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRev.80.580"},{"key":"p_39","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRev.94.630"},{"key":"p_40","doi-asserted-by":"publisher","DOI":"10.1063\/1.1716296"},{"key":"p_41","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/41\/12\/009"},{"key":"p_42","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/41\/12\/010"},{"key":"p_43","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(97)00146-6"},{"key":"p_44","doi-asserted-by":"publisher","DOI":"10.1118\/1.597578"},{"key":"p_45","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/44\/10\/305"},{"key":"p_46","first-page":"803","volume":"23","author":"Audet C","year":"1996","journal-title":"Med Phys"},{"key":"p_47","doi-asserted-by":"publisher","DOI":"10.1118\/1.598432"},{"key":"p_48","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/0360-3016(92)90189-O","volume":"24","author":"Carol M","year":"1992","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"p_49","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-8140(99)00019-5"},{"key":"p_50","first-page":"1070","volume":"23","author":"Ibbott GS","year":"1996","journal-title":"Med Phys"},{"key":"p_51","doi-asserted-by":"publisher","DOI":"10.1016\/S0730-725X(96)00380-3"},{"key":"p_52","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/44\/8\/310"}],"container-title":["The British Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/73\/873\/919\/54977700\/bjr.73.873.11064643.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/73\/873\/919\/54977700\/bjr.73.873.11064643.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,12]],"date-time":"2024-01-12T16:24:59Z","timestamp":1705076699000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjr\/article\/73\/873\/919-29\/7321412"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,9,1]]},"references-count":52,"journal-issue":{"issue":"873","published-online":{"date-parts":[[2014,1,28]]},"published-print":{"date-parts":[[2000,9,1]]}},"URL":"https:\/\/doi.org\/10.1259\/bjr.73.873.11064643","relation":{},"ISSN":["1748-880X","0007-1285"],"issn-type":[{"value":"1748-880X","type":"electronic"},{"value":"0007-1285","type":"print"}],"subject":[],"published-other":{"date-parts":[[2000,9,1]]},"published":{"date-parts":[[2000,9,1]]}}}