{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T23:16:39Z","timestamp":1773011799161,"version":"3.50.1"},"reference-count":26,"publisher":"Japanese Society for Hygiene","issue":"0","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Jpn. J. Hyg.","Nippon Eiseigaku Zasshi (Japanese Journal of Hygiene), Jpn. J. Hyg.","Nippon Eiseigaku Zasshi (Japanese Journal of Hygiene)"],"published-print":{"date-parts":[[2020]]},"DOI":"10.1265\/jjh.19021","type":"journal-article","created":{"date-parts":[[2020,3,25]],"date-time":"2020-03-25T22:04:45Z","timestamp":1585173885000},"page":"n\/a","source":"Crossref","is-referenced-by-count":4,"title":["Efficacy of Slightly Acidic Electrolyzed Water against Contamination of Water Line of Dental Units","\u6b6f\u79d1\u7528\u30c1\u30a7\u30a2\u30e6\u30cb\u30c3\u30c8\u306e\u6c34\u56de\u8def\u306e\u6c5a\u67d3\u306b\u5bfe\u3059\u308b\u5fae\u9178\u6027\u96fb\u89e3\u6c34\u306e\u6709\u52b9\u6027"],"prefix":"10.1265","volume":"75","author":[{"given":"Masako","family":"NAKANO","sequence":"first","affiliation":[{"name":"Department of Endodontology, Tsurumi University School of Dental Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayuko","family":"TAKAO","sequence":"additional","affiliation":[{"name":"Department of Oral Microbiology, Tsurumi University School of Dental Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuko","family":"MAEDA","sequence":"additional","affiliation":[{"name":"Department of Oral Microbiology, Tsurumi University School of Dental Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Noriyasu","family":"HOSOYA","sequence":"additional","affiliation":[{"name":"Department of Endodontology, Tsurumi University School of Dental Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"335","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"(1) Mills SE, Lauderdale PW, Mayhew RB. Reduction of microbial contamination in dental units with povidone-iodine 10%. J Am Dent Assoc 1986;113:280\u2013284.","DOI":"10.14219\/jada.archive.1986.0178"},{"key":"2","unstructured":"(2) Williams JF, Andrews N, Santiago JI. Microbial contamination of dental unit waterlines: current preventive measures and emerging options. Compend Contin Educ Dent 1996;17:691\u2013709."},{"key":"3","unstructured":"(3) Miller CH. Microbes in dental unit water. J Calif Dent Assoc 1996;24:47\u201352."},{"key":"4","doi-asserted-by":"crossref","unstructured":"(4) Barbeau J, Tanguay R, Faucher E, Avezard C, Trudel L, C\u00f4t\u00e9 L, et al. Multiparametric analysis of waterline contamination in dental units. Appl Environ Microbiol 1996;62:3954\u20133959.","DOI":"10.1128\/AEM.62.11.3954-3959.1996"},{"key":"5","doi-asserted-by":"crossref","unstructured":"(5) Barbeau J, Gauthier C, Payment P. Biofilms, infectious agents and dental unit waterlines: a review. Can J Microbiol 1998;44:1019\u20131028.","DOI":"10.1139\/w98-101"},{"key":"6","doi-asserted-by":"crossref","unstructured":"(6) Williams HN, Paszko-Kolva C, Shahamat M, Palmer C, Pettis C, Kelley J. Molecular techniques reveal high prevalence of Legionella in dental units. J Am Dent Assoc 1996;127:1188\u20131193.","DOI":"10.14219\/jada.archive.1996.0410"},{"key":"7","doi-asserted-by":"crossref","unstructured":"(7) Williams JF, Johnston AM, Johnson B, Huntington MK, Mackenzie CD. Microbial contamination of dental unit waterlines: prevalence, intensity and microbiological characteristics. J Am Dent Assoc 1993; 124:59\u201365.","DOI":"10.14219\/jada.archive.1993.0205"},{"key":"8","doi-asserted-by":"crossref","unstructured":"(9) Tall BD, Williams HN, George KS, Gray RT, Walch M. Bacterial succession within a biofilm in water supply lines of dental air-water syringes. Can J Microbiol 1995;41:647\u2013654.","DOI":"10.1139\/m95-088"},{"key":"9","doi-asserted-by":"crossref","unstructured":"(10) Walker JT, Bradshaw DJ, Finney M, Fulford MR, Frandsen E, \u00d8Stergaard E, et al. Microbiological evaluation of dental unit water systems in general dental practice in Europe. Eur J Oral Sci 2004;112:412\u2013418.","DOI":"10.1111\/j.1600-0722.2004.00151.x"},{"key":"10","doi-asserted-by":"publisher","unstructured":"(11) Coleman DC, O\u2019Donnel MJ, Shore AC Russel RJ. Biofilm problems in dental unit water systems and its practical control. J Appl Microbiol 2009;106:1424\u20131437. doi: 10.1111\/j.1365-2672.2008.04100.x.","DOI":"10.1111\/j.1365-2672.2008.04100.x"},{"key":"11","doi-asserted-by":"publisher","unstructured":"(12) Ricci ML, Fontana S, Pinci F, Fiumana E, Pedna MF, Farolfi P, et al. Pneumonia associated with a dental unit waterline. Lancet 2012;18:379(9816):684. doi: 10.1016\/S0140-6736(12)60074-9.","DOI":"10.1016\/S0140-6736(12)60074-9"},{"key":"12","doi-asserted-by":"publisher","unstructured":"(13) Sch\u00f6nning C, Jernberg C, Klingenberg D, Andersson S, P\u00e4\u00e4j\u00e4rvi A, Alm E, et al. Legionellosis acquired through a dental unit: a case study. J Hosp Infect 2017;96:89\u201392. doi: 10.1016\/j.jhin.2017.01.009.","DOI":"10.1016\/j.jhin.2017.01.009"},{"key":"13","doi-asserted-by":"crossref","unstructured":"(14) ADA Council on Scientific Affairs and ADA Council on Dental Practice. Infection control recommendations for the dental office and the dental laboratory. J Am Dent Assoc 1996;127:672\u2013680.","DOI":"10.14219\/jada.archive.1996.0280"},{"key":"14","doi-asserted-by":"crossref","unstructured":"(15) Kohn WG, Harte JA, Malvitz DM Collins AS, Cleveland JL, Eklund KJ. Guidelines for infection control in dental health care settings\u20142003. J Am Dent Assoc 2004;135:33\u201347.","DOI":"10.14219\/jada.archive.2004.0019"},{"key":"15","doi-asserted-by":"crossref","unstructured":"(16) Larsen T, Fiehn NE. The effect of Sterilex Ultra for disinfection of dental unit waterlines. Int Dent J 2003;53:249\u2013254.","DOI":"10.1111\/j.1875-595X.2003.tb00753.x"},{"key":"16","unstructured":"(17) Coan LL, Hughes EA, Hudson JC, Palenik CJ. Sampling water from chemically cleaned dental units with detachable power scalers. J Dent Hyg 2007;81:80."},{"key":"17","unstructured":"(18) Zhang W, Onyango O, Lin Z, Lee SS, Li Y. Evaluation of Sterilox for controlling microbial biofilm contamination of dental water. Compend Contin Educ Dent 2007;28:586\u2013592."},{"key":"18","doi-asserted-by":"crossref","unstructured":"(19) Wirthlin MR, Marshall GW Jr, Rowland RW. Formation and decontamination of biofilms in dental unit waterlines. J Periodontol 2007;74:1595\u20131609.","DOI":"10.1902\/jop.2003.74.11.1595"},{"key":"19","doi-asserted-by":"crossref","unstructured":"(27) Yamamura K. Transformation using (x + 0.5) to stabilize the variance of populations. Res Popul Ecol 1999;41:229\u2013234.","DOI":"10.1007\/s101440050026"},{"key":"20","unstructured":"(28) http:\/\/www.city.yokohama.lg.jp\/ex\/stat\/toukeisho\/new\/ (2018.1.11)"},{"key":"21","doi-asserted-by":"publisher","unstructured":"(29) Kanda Y. Investigation of the freely available easy-to-use software \u2018EZR\u2019 for medical statistics. Bone Marrow Transplant 2013;48:452\u2013458. doi: 10.1038\/bmt.2012.244.","DOI":"10.1038\/bmt.2012.244"},{"key":"22","unstructured":"(30) https:\/\/www.mhlw.go.jp\/stf\/seisakunitsuite\/bunya\/topics\/bukyoku\/kenkou\/suido\/kijun\/kijunchi.html (2018.1.22)"},{"key":"23","doi-asserted-by":"crossref","unstructured":"(32) https:\/\/www.mhlw.go.jp\/file\/06-Seisakujouhou-10800000-Iseikyoku\/02-01_1.pdf (2018.1.22)","DOI":"10.30699\/acadpub.jru.2.2.1"},{"key":"24","unstructured":"(33) https:\/\/www.mhlw.go.jp\/shingi\/2002\/10\/s1007-5c.html (2018.1.22)"},{"key":"25","doi-asserted-by":"crossref","unstructured":"(39) Komachiya M, Yamaguchi A, Hirai K, Kikuchi Y, Mizoue S, Takeda N, et al. Antiseptic Effect of Slightly Acidic Electrolyzed Water on Dental Unit Water Systems. Bull Tokyo Dent Coll 2014;55(2):77\u201386.","DOI":"10.2209\/tdcpublication.55.77"},{"key":"26","doi-asserted-by":"publisher","unstructured":"(40) Yabune T, Imazato S, Ebisu S. Assessment of inhibitory effects of fluoride-coated tubes on biofilm formation by using the in vitro dental unit waterline biofilm model. Appl Environ Microbiol 2008;74:5958\u20135964. doi: 10.1128\/AEM.00610-08.","DOI":"10.1128\/AEM.00610-08"}],"container-title":["Nippon Eiseigaku Zasshi (Japanese Journal of Hygiene)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjh\/75\/0\/75_19021\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,3,28]],"date-time":"2020-03-28T03:36:41Z","timestamp":1585366601000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjh\/75\/0\/75_19021\/_article\/-char\/ja\/"}},"subtitle":["\u2014Continuous Investigation over Seven Years\u2014","\u20157\u5e74\u9593\u306b\u308f\u305f\u308b\u7d99\u7d9a\u8abf\u67fb\u2015"],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":26,"journal-issue":{"issue":"0","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1265\/jjh.19021","relation":{},"ISSN":["0021-5082","1882-6482"],"issn-type":[{"value":"0021-5082","type":"print"},{"value":"1882-6482","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}