{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T05:06:55Z","timestamp":1772168815926,"version":"3.50.1"},"update-to":[{"DOI":"10.12688\/f1000research.139090.1","type":"new_version","label":"New version","source":"publisher","updated":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T00:00:00Z","timestamp":1741305600000}}],"reference-count":13,"publisher":"F1000 Research Ltd","license":[{"start":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T00:00:00Z","timestamp":1741305600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["f1000research.com"],"crossmark-restriction":false},"short-container-title":["F1000Res"],"abstract":"<ns3:p>Background Mesh implementation to repair the hiatal space is already justified. Nevertheless, the use of this procedure is debated in regard of complications that may occur. Mesh erosion and migration are considered the most serious complications of mesh repairs. Case presentation It has not yet been well described in the literature. We describe a case of mesh erosion of stomach, many years later after a prosthetic repair of a diaphragmatic rupture associated to hiatal hernia, is presented here because of its rarity. Conclusion Few explanations have been put forward to explain this incident. Could it be due to inflammatory processes, or to the composition of the Meshes? As yet, there is no definitive explanation.<\/ns3:p>","DOI":"10.12688\/f1000research.139090.2","type":"journal-article","created":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T09:20:07Z","timestamp":1741339207000},"page":"871","update-policy":"https:\/\/doi.org\/10.12688\/f1000research.crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Case Report: Total intragastric mesh migration six years after diaphragmatic rupture and hiatal hernia surgery"],"prefix":"10.12688","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7691-2186","authenticated-orcid":false,"given":"Asma","family":"Sghaier","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9971-0747","authenticated-orcid":false,"given":"Mohamed Amine","family":"Elghali","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdelrahmen","family":"Daadoucha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amal","family":"Letaief","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Itimed","family":"GHARBI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fehmi","family":"Hamila","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sabri","family":"Youssef","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2560","published-online":{"date-parts":[[2025,3,7]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"349-353","DOI":"10.1016\/j.ijscr.2012.04.011","article-title":"Diaphragmatic rupture: Is management with biological mesh feasible?","volume":"3","author":"O Al-Nouri","year":"2012","journal-title":"Int. J. Surg. Case Rep."},{"key":"ref2","doi-asserted-by":"publisher","first-page":"4257-4280","DOI":"10.1007\/s00464-020-07723-0","article-title":"Mesh-related complications in paraoesophageal repair: a systematic review.","volume":"34","author":"C Spiro","year":"2020 Oct","journal-title":"Surg. Endosc."},{"key":"ref3","doi-asserted-by":"publisher","first-page":"388-394","DOI":"10.4240\/wjgs.v11.i10.388","article-title":"Use of absorbable meshes in laparoscopic paraesophageal hernia repair World.","volume":"11","author":"M Bernab\u00e9","year":"2019 October 27","journal-title":"J. Gastrointest. Surg."},{"key":"ref4","doi-asserted-by":"publisher","first-page":"90-92","DOI":"10.1007\/s10029-004-0243-4","article-title":"Late bilateral diaphragmatic rupture: challenging diagnostic and surgical repair.","volume":"9","author":"H Sirbu","year":"2005 Mar","journal-title":"Hernia."},{"key":"ref5","first-page":"222-225","article-title":"Complications of Mesh Repair in Hiatal Surgery: About 3 Cases and Review of the Literature.","volume":"22","author":"M Veronique","year":"2012","journal-title":"Surg. Laparosc. Endosc. Percutan. Tech."},{"key":"ref6","doi-asserted-by":"publisher","first-page":"e24339","DOI":"10.7759\/cureus.24339","article-title":"Intraesophageal Migration of a Paraesophageal Hernia Mesh: A Case Report.","volume":"14","author":"A Idrissi","year":"2022 Apr 21","journal-title":"Cureus."},{"key":"ref7","doi-asserted-by":"publisher","first-page":"226-238","DOI":"10.1016\/j.amjsurg.2015.07.007","article-title":"A systematic review and meta-analysis of mesh versus suture cruroplasty in laparoscopic large hiatal hernia repair.","volume":"211","author":"V Tam","year":"2016 January","journal-title":"Am. J. Surg."},{"key":"ref8","doi-asserted-by":"publisher","first-page":"139-141","DOI":"10.1089\/lap.2011.0340","article-title":"Long-term results of giant hiatal hernia mesh repair and antireflux laparoscopic surgery for gastroesophageal reflux disease.","volume":"22","author":"P Priego","year":"2012","journal-title":"J. Laparoendosc. Adv. Surg. Tech. A."},{"key":"ref9","doi-asserted-by":"publisher","first-page":"1219-1226","DOI":"10.1007\/s00464-008-0205-5","article-title":"Mesh complications after prosthetic reinforcement of hiatal closure: A 28-case series.","volume":"23","author":"R Stadlhuber","year":"2009","journal-title":"Surg. Endosc."},{"key":"ref10","doi-asserted-by":"publisher","first-page":"106-109","DOI":"10.1016\/j.ijsu.2007.12.004","article-title":"Rejection of goretex mesh used in prosthetic cruroplasty: A case series.","volume":"6","author":"P Griffith","year":"2008","journal-title":"Int. J. Surg."},{"key":"ref11","first-page":"226-229","article-title":"Mesh-related complications after hiatal hernia repair: two case reports.","volume":"38","author":"L Wei-T","year":"2015","journal-title":"Gastroenterol. Nurs."},{"key":"ref12","doi-asserted-by":"publisher","first-page":"3295-3302","DOI":"10.1007\/s00464-018-6050-2","article-title":"A word of caution: never use tacks for mesh fixation to the diaphragm!","volume":"32","author":"F K\u00f6ckerling","year":"2018: Jul","journal-title":"Surg. Endosc."},{"key":"ref13","doi-asserted-by":"publisher","first-page":"140-146","DOI":"10.1089\/lap.2019.0431","article-title":"Paraesophageal hernia: to mesh or not to mesh? The controversy continues.","volume":"30","author":"C Balagu\u00e9","year":"2020","journal-title":"J. Laparoendosc. Adv. Surg. Tech. A."}],"container-title":["F1000Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/f1000research.com\/articles\/12-871\/v2\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/f1000research.com\/articles\/12-871\/v2\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/f1000research.com\/articles\/12-871\/v2\/iparadigms","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,12]],"date-time":"2025-03-12T02:20:11Z","timestamp":1741746011000},"score":1,"resource":{"primary":{"URL":"https:\/\/f1000research.com\/articles\/12-871\/v2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,7]]},"references-count":13,"URL":"https:\/\/doi.org\/10.12688\/f1000research.139090.2","relation":{"has-version":[{"id-type":"doi","id":"10.12688\/f1000research.139090.1","asserted-by":"subject"}],"has-review":[{"id-type":"doi","id":"10.5256\/f1000research.178358.r369923","asserted-by":"subject"},{"id-type":"doi","id":"10.5256\/f1000research.178358.r369923","asserted-by":"object"}]},"ISSN":["2046-1402"],"issn-type":[{"value":"2046-1402","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,7]]},"assertion":[{"value":"Indexed","URL":"https:\/\/f1000research.com\/articles\/12-871\/v2#article-reports","order":0,"name":"referee-status","label":"Referee status","group":{"name":"current-referee-status","label":"Current Referee Status"}},{"value":"10.5256\/f1000research.152335.r205919, Ivan Romic, Department of Surgery, University Hospital Centre Zagreb, Zagreb, 10 Oct 2023, version 1, 1 approved, 1 not approved","URL":"https:\/\/f1000research.com\/articles\/12-871\/v1#referee-response-205919","order":0,"name":"referee-response-205919","label":"Referee Report","group":{"name":"article-reports","label":"Article Reports"}},{"value":"<b>Asma SGHAIER<\/b>; \n<i>Posted: 16 Feb 2025<\/i>; \n<b>Detailed Response to Reviewers<\/b>  \n<b>Dear Professor<\/b>&nbsp;\n<b>Ivan Romic<\/b>  Thank you for your letter and for the reviewers\u2019 comments concerning our manuscript. Thank you very much for your consideration, and we really appreciate the comments and have learned a lot. Appropriate changes were made according to the suggestions of reviewers and editor.  Those comments are all valuable and very helpful for revising and improving our paper, as well as the important guiding significance to our researches. We have studied comments carefully and have made correction which we hope meet with approval.  The MESH used is a polypropylene material with two faces, one water- resistant and the other water-repellent. we are under a moral obligation to refrain from using the brand name for ethical reasons and to avoid any conflict of interest.  There were several fibrous adhesions which were difficult to dissect. Attempts to access the supra-mesocolic floor and hiatal region were unsuccessful and not safe. Conversion to open surgery was mandatory.  The necessary revisions were included in the manuscript  \n<b>We express once again our sincere appreciation and deep gratitude to all the reviewers and to the editorial board for providing us with the opportunity to revise our manuscript and to improve the quality of our submission.<\/b>  \n<b>We hope, nevertheless, to receive positive feedback and acceptance of our work by allowing it to be published in this prestigious journal.<\/b>  \n<b>Sincerely<\/b> \n<b>The corresponding author <\/b>","URL":"https:\/\/f1000research.com\/articles\/12-871\/v2#referee-comment-13366","order":1,"name":"referee-comment-13366","label":"Referee Comment","group":{"name":"article-reports","label":"Article Reports"}},{"value":"10.5256\/f1000research.178358.r369923, Nir Messer, Cleveland Clinic Foundation, Cleveland, 12 Mar 2025, version 2, indexed","URL":"https:\/\/f1000research.com\/articles\/12-871\/v2#referee-response-369923","order":2,"name":"referee-response-369923","label":"Referee Report","group":{"name":"article-reports","label":"Article Reports"}},{"value":"The author(s) declared that no grants were involved in supporting this work","order":3,"name":"grant-information","label":"Grant Information"},{"value":"This is an open access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.","order":0,"name":"copyright-info","label":"Copyright"}]}}